28
29
Lower Limit Switch
reMoVe aND repLaCe
This switch sets the lower travel limit for the ram
mechanism.
1. Remove the back panel from the cabinet cover (see
Access to Components, Remove Cabinet Cover).
2. Remove two Phillips head screws and the switch
from the center stabilizer plate.
3. Noting their locations, transfer the wires to the
replacement switch.
4. Install the switch and secure with two Phillips head
screws.
section D – electrical Components
Motor Centrifugal Switch
Assembly
reMoVe aND repLaCe
This switch reverses the motor when peak load is
reached.
1. Remove the control panel assembly from the front of
the unit (see Control Panel Assembly, Remove and
Re-install).
2. Remove two Phillips head screws and the switch
from the bottom of the motor.
3. Noting their locations, transfer the wires to the
replacement switch.
4. Install the switch and secure with two Phillips head
screws.
S CREWS
S WITCH
POWER U NIT
MECHANISM
S CREWS
S CREWS