5. Installation 

5.1 Place of installation

The installation of central unit is following to the layout of the piping set by an appointed 
installer. Considering the construction’s features, the protection class IP55 and the moderate 
noise level, the Matrix units can be installed even outdoor. 

The minimal room for installation chamber is
70 x 60 cm (lxh)

5.2 Inlet reversibility

The Matrix unit is usually delivered with inlet connection assembled on the right side of the 
unit. When necessary, it is possible to switch the central unit form right to left, by assembling 
the inlet on the left side. 
1.  Open the front cover with quick-fix magnets
2.  Loosen the 3 screws from inside and remove the inlet muff
3.  In the opposite side unscrew in the same way the inlet cap

4.  Change the inlet muff with the inlet cap

Paying attention to the right positioning of the joints. 

1

2

3

4. Technical data :

Field of application

Matrix - PT

Matrix - FF

area up to

m2 130

m2 130

max. tube length

ca. 30

ca. 30

max. inlet valves

Stk. 3-4

Stk. 3-4

TECHNICAL FEATURES:

Power

kW 1,5

kW 1,5

Motor stage

 1

 1

Inlet power supply

Volt 230

Volt 230

IPX Protection degree

 IP55

 IP55

Max Vacuum

mbar 260

mbar 260

Max air volume

m3/h 220

m3/h 190

Airwatt @ ø 32mm

W 421

W 378

Filtration

 

Paper Bag

 

Flat filter

Filtration surface

cm2 3350

cm2 5200

Housing

 ABS

 ABS

Dust container capacity

L 5

L 3,5

Max Noise Level

dB 59

dB 59

Size

cm 23x39x49,5

cm 23x39x49,5

Weight

kg 7,5

kg 7,6

6

Summary of Contents for MATRIX RANGE

Page 1: ...MATRIX RANGE User s manual...

Page 2: ......

Page 3: ...installation 7 5 2 Inlet reversibility 7 5 3 Fixing of central unit 9 5 4 Connection to pipe network 11 5 5 Electrical connection 12 6 Use of central unit 13 6 1 Use of accessories 13 7 Maintenance 14...

Page 4: ......

Page 5: ...artridge and easy collection of the dust 2 Unpacking Follow the instruction printed on the cardboard box to move the central unit to the location selected for installation Open the box remove internal...

Page 6: ...1 Central unit 2 Metal fixing plate 3 Two rubber muffs 4 Four clamps for rubber muffs 5 Paper bag 6 User s guide and Guarantee coupon 7 Installation template Every central unit manufactured and packag...

Page 7: ...3 Construction scheme Matrix FF Motor Disposable bag Flat filter Dust container Motor protection Cover with quick fix Matrix PT 4...

Page 8: ...W 1 5 Motor stage 1 1 Inlet power supply Volt 230 Volt 230 IPX Protection degree IP55 IP55 Max Vacuum mbar 260 mbar 260 Max air volume m3 h 220 m3 h 190 Airwatt 32mm W 421 W 378 Filtration Paper Bag F...

Page 9: ...s 70 x 60 cm lxh 5 2 Inlet reversibility The Matrix unit is usually delivered with inlet connection assembled on the right side of the unit When necessary it is possible to switch the central unit for...

Page 10: ...ell as the installation wall plate 1 The template should be fixed on the wall where the central unit should be installed For reference the inlet and outlet should be considered 2 Mark the drilling poi...

Page 11: ...st grid 5 5 Electrical connection Before plugging in the central unit make sure that the main power supply correspond to the voltage requirements written on the label which referred to the data on the...

Page 12: ...for any harm or damage done due to misuse of the central unit 6 1 Use of accessories 1 Place the suitable ends together Into the handle into the two chrome plated extensions or into the chrome plated...

Page 13: ...ain power and when the cleaner and other parts are chilled form the surrounding temperature This maintenance is made to keep the cleaner working properly and to extend the lifetime of the cleaner Empt...

Page 14: ...the dust contai ner and check also the motor protection On Matrix FF check if the dust container drawer is full and the condition of the flat polyester filter 2 Safety protection The 10 Amp fuse blow...

Page 15: ...d or not well secured The air loss in connection with a whistling noise by a closed inlet valve is caused by a not perfect sealing or screwing of the inlet with pipes Check the tightness and if needed...

Page 16: ...of the present manual Not sending of guarantee coupon The manufacturer will replace under guarantee any parts that are found to be defective due to faulty construction All defective parts must be retu...

Page 17: ...Certificato di garanzia Garantieschein Coupon of Guarantee Certificat de Garantie da affrancare zu frankieren to stamp d affranchir 14...

Page 18: ...T i m b r o e f i r m a d e l v e n d i t o r e S t e m p e l u n d U n t e r s c h i e d d e s V e r k u f e r S t a m p a n d s i g n o f s e l l e r C a c h e t e t s i g n a t u r e 15...

Page 19: ...16...

Page 20: ...central vacuum systems...

Reviews: