![DIS Sensors QG65N2 Series User Manual Download Page 27](http://html1.mh-extra.com/html/dis-sensors/qg65n2-series/qg65n2-series_user-manual_2508536027.webp)
Page
26
of
32
User Manual - QG65N2 SAE J1939 Inclinometer (Type JB) V1.1
Index
Subindex
Data
Type
Access
Object Name and description
Factory Default
Detail
6000
h
00
h
U16
r
Resolution
10
d
=0.01, 100
d
=0.1, 1000
d
=1.0
10
d
6012
h
00h
S16
rw
Pre-set Inclination X-axis
0000
h
6013
h
00
h
S16
rw
Offset Inclination X-axis
0000
h
6022
h
00
h
S16
rw
Pre-set Inclination Y-axis
0000
h
6023
h
00
h
S16
rw
Offset Inclination Y-axis
0000
h
Table 18 - Communication Profile
Use index 1010 t
o permanently save communication parameters in the EEPROM of the device, otherwise the changes will
be lost after a power cycle. All indices and/or subindices not described in the table are reserved exclusively for factory use.
Data types used in the application layers are explained in the following table.
Data type
Definitions
U8
Unsigned 8-bit number (0 – 255
d
)
U16
Unsigned 16-bit number (0 – 65535
d
)
U32
Unsigned 32-bit number (0 – 4294967295
d
)
S8/Integer 8
Signed integer 8-bit number (-128
d
– +127
d
)
S16/Integer 16
Signed integer 16-bit number (-32768
d
– +32767
d
)
S32/Integer 32
Signed integer 16-bit number (-2147483648
d
– +2147483647
d
)
Table 19 - Data type