![DIS Sensors QG65N2 Series User Manual Download Page 23](http://html1.mh-extra.com/html/dis-sensors/qg65n2-series/qg65n2-series_user-manual_2508536023.webp)
Page
22
of
32
User Manual - QG65N2 SAE J1939 Inclinometer (Type JB) V1.1
DA:
defines the specific address to which the message is being sent.
GE:
provides extra 4096 PGNs per data page.
Table 15 - PGN definition
PGNs used by DIS J1939 sensors are explained as below:
PGN
PG Name
J1939 Definition
DIS
61184
d
(00EF00
h
)
PropA
This PG uses the destination-specific PDU1 Format
allowing manufacturers to direct their proprietary
communications to a specific destination node. How the
Data field of this message is used is up to each
manufacturer.
Sensor configuration is sent with
PGN 61184
65280
d
(00FF00
h
)
PropB
This PG uses the PDU2 Format message allowing
manufacturers to define the PS (GE) field content as
they desire.
Inclination output is sent by PGN
65280.
65283
d
(00FF03
h
)
PropB
This PG uses the PDU2 Format message allowing
manufacturers to define the PS (GE) field content as
they desire.
Acceleration output is sent by PGN
65283.
60928
d
(00EE00
h
)
AC
The Address Claimed PGN may be used in two ways: to
claim an address, and to announce that a CA was unable
to claim an address.
ACM
59904
d
Request
Message
The request message (PGN 59904) for the Address
Claimed message (PGN 60928) is used by any CA to
request the NAMEs and addresses of CAs in ECUs
attached to the network.
RQST
Table 16 - PGN examples