![Dirt Devil MCE5700 Owner'S Manual Download Page 6](http://html.mh-extra.com/html/dirt-devil/mce5700/mce5700_owners-manual_2508331006.webp)
11
FILTER: CLEANING AND REPLACEMENT
Remove Tank-in-Tank
™
System by pushing
down on tank latch and
tilting out from cleaner.
Turn unit off and unplug
from electrical outlet.
1.
Remove filter from filter/
float assembly by grasping
angled top of filter and turning
counterclockwise. Lift filter
up and out of filter assembly.
Remove any loose debris from filter by tapping
the filter against a garbage can.
NOTE:
For
additional cleaning, the filter may be rinsed
under water (Diagrams a and b). Allow filter
to air dry completely before use.
Grasp tab on filter/float
assembly and pull up to
remove from tank.
5.
3.
4.
a.
b.
2.
Replace filter by grasping angled top of filter and turning clockwise
to lock onto filter/float assembly. Return filter/float assembly to
Dirty Water Tank. To ensure proper fit, make sure the arrow on the
filter/float assembly lines up with the Align Filter Front arrow.
6.
6a.
WARNING:
TO REDUCE THE RISK OF INJURY FROM MOVING PARTS - UNPLUG BEFORE SERVICING.
NOTE:
For best results, clean filter after each use and replace annually. For filter replacements, please call
1-800-321-1134 or visit www.dirtdevil.com to locate a dealer nearest you.
TO CLEAN FILTER
TRANSPORTING AND STORING SHAMPOOER
BEFORE STORING SHAMPOOER:
• Empty and rinse Tank-in-Tank
™
System
• Clean filter
• Replace Tank-in-Tank
™
System
• Wrap cord around quick cord
release and lower cord wrap
• Make sure that unit is fully dry
prior to storing.
• Put handle in locked position.
• Turn unit off.
• Store cord.
• Tilt unit back on rear wheels
and push forward.
NOTE:
The
unit can also be transported
between rooms and should
only be used to transport
between floors using the carry
handle (See Features section
page 5).
1.
TRANSPORTING SHAMPOOER
STORING SHAMPOOER
NOTE:
Do not store unit with a full Clean Water Tank or Dirty Water Tank.
WARNING: DO NOT STORE THE SHAMPOOER IN GARAGE OR AREA WHERE UNIT COULD FREEEZE.
WARNING:
TO REDUCE RISK OF PERSONAL INJURY - UNPLUG SHAMPOOER BEFORE SERVICING
ANY OTHER SERVICING SHOULD BE DONE BY AN AUTHORIZED SERVICE REPRESENTATIVE
CUSTOMER SERVICE (1-800-321-1134)
In the event that further assistance is required, see your Yellow Pages for an authorized Royal
®
Dealer. Costs of any
transportation to and from any place of repair are to be paid by the owner. The service parts used in this unit are
easily replaced and readily available from an authorized Royal
®
Dealer or retailer. Always identify your cleaner by
the model number and manufacturing code when requesting information or ordering replacement parts. (The model
number appears on the bottom of the cleaner.)
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
Shampooer won’t
run
Shampooer won’t
pick-up or low
suction
Water escaping
from shampooer
Shampooer won’t
dispense solution
Brushroll not
rotating*
1. Power cord not firmly plugged
into outlet.
2. Blown fuse or tripped breaker.
3. Brush clogged.
4. Thermal Protector activated.
5. Needs service.
1. Incorrectly assembled.
2. Clean/Dirty Water Tank not
installed properly.
3. Dirty water tank is full.
4. Nozzle clogged
5. Filter clogged or dirty.
6. Incorrect nozzle attached.
1. Dirty Water Tank is full.
2. Clean/Dirty Water Tank
not installed properly.
3. Solution trigger pulled.
1. Clean/Dirty Water Tank not
installed properly.
2. Clean Water Tank empty.
3. Solution trigger not pulled
1. Brush On/Off switch not in
ON position
2. Brushroll clogged
3. Belt broken
1. Plug unit in firmly.
2. Check fuse or breaker in home. Replace
fuse/reset breaker.
3. Remove debris from brushroll and push
motor reset button.
4. Unplug shampooer. Allow to cool for 30
minutes before use.
5. Take to service center or call
1-800-321-1134.
1. Reassemble shampooer.
2. Secure tank - Pg.10
.
3. Empty Dirty Water Tank - Pg.10
4. Clean nozzle opening.
5. Remove filter and clean - Pg. 11
6. Attach correct nozzle (blue for hard floors,
green for carpets) - Pg. 8
1. Empty Dirty Water Tank - Pg. 10
2. Secure Tank - Pg. 10
3. Release solution trigger.
1. Secure Tank.
2. Fill Clean Water Tank.
3. Pull solution trigger.
1. Move Brush On/Off switch to ON position.
2. Unplug unit. Remove debris from brushroll
and push motor reset button.
3. Take to a service center of call
1-800-321-1134.
*
Press reset button.
TROUBLESHOOTING GUIDE