background image

IMPORTANT SAFETY INSTRUCTIONS 

 

SAVE THESE INSTRUCTIONS –This manual 
contains important instructions  for model 

Vesta Pro

 1000/1400/2000 VAC that should 

be followed during installation and 
maintenance of the UPS and batteries. 
 

Safety – CAUTION! 

 

 

This UPS utilizes voltages that may be hazardous. Do not attempt to 

disassemble the unit. The unit contains no user serviceable parts. 

Only factory service personnel may perform repairs. 

 

Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery. 

 

Connection to any other type of receptacle other than a two-pole, 

three-wire grounding receptacle may result in s shock hazard as well 

as violate local electrical codes. 

 

In the event of an emergency, turn the power switch to the “off” 

position and disconnect the power cord form the AC power supply to 

properly disable the UPS 

 

Do not allow any liquids or any foreign object to enter the UPS. Do 

not place beverages or any other liquid-containing vessels on or near 

the unit. 

 

This unit intended for installation in a controlled environment 

(temperature controlled, indoor area free of conductive contaminants). 

Avoid installing the UPS in locations where there is standing or 

running water, or excessive humidity. 

 

Do not plug the UPS input into its own output. 

 

Do not attach a power strip or surge suppressor to the UPS. 

 

Do not attach non-computer-related items, such as medical 

equipment, life-support equipment, microwave ovens, or vacuum 

cleaners to UPS 

 

To reduce the risk of overheating the UPS, do not cover the UPS’ 

cooling vents and avoid exposing the unit to direct sunlight or 

installing the unit near heat emitting appliances such as space heaters 

or furnaces. 

 

Summary of Contents for vesta pro 1000 vac

Page 1: ......

Page 2: ......

Page 3: ... position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in lo...

Page 4: ...arts on the top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number of the sealed lead acid batteries This pluggable type A eq...

Page 5: ...System Description Front Panel 1 LCD Back Light 2 Power ON OFF Switch Back Panel 1 Communication Port 2 Cooling Fan 3 AC Output 4 Modem Phone Line Surge Protection 5 Circuit Breaker 6 AC Input ...

Page 6: ...all the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factory...

Page 7: ...back of the UPS maximum of three devices 5 Modem Phoneline Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown ...

Page 8: ...unit press the power switch again When Swith ON The LED lighting 7 LCD Display Specification The LED will always turns on when UPS works including in off charging mode and fault mode When LCD start to work it will display all information for 3s a When in normal mode it will display as below ...

Page 9: ...ery mode it will display as below And the mark will flicker every 1second Note If I P V 20V input voltage will display 000 d When in off charging mode it will display as below Note the output voltage always is displayed as 000 in off charging mode e When in fault mode it will display as below FAULT ...

Page 10: ...character and the reason of fault only ...

Page 11: ... 100 7 Battery capacity definition Battery LEVEL Battery bar Indication Battery voltage 11V 11V Battery voltage 11 5V 11 5V Battery voltage 12 5V Battery voltage 12 5V 8 When over load the mark will flicker every 1second 9 When battery low the mark will flicker every 1second ...

Page 12: ...failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPSs Installation procedure 1 Go to the website http www ups software download com index htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 0...

Page 13: ...Verify that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 10 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Communication lost between UPS and...

Page 14: ...ANSFER TIME Typical 4 8ms INDICATOR LCD Display Models The LCD will always turn on when UPS work Including in off charging mode and fault mode AUDIBLE ALARM Battery Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0 5 second Battery Replace Sounding every 2 seconds Fault Continuously sounding PROTECTION Full Protection Discharge Overcharge Short Circuit and ...

Reviews: