![DirectOut Technologies EXBOX.AES User Manual Download Page 37](http://html1.mh-extra.com/html/directout-technologies/exbox-aes/exbox-aes_user-manual_2507546037.webp)
page 37 of 60
EXBOX.AES Manual - Version 2.0
CHAPTER 4: Operation
Embedder / De-Embedder
The local RS 232 port can both be used to embed
serial data into the MADI output signal and to
de-embed serial data from the MADI input signal. The
serial data is tunnelled by using the user bits of audio
channel 1 to 9.
RS 232
DSUB-9 socket*
Serial data I/O - connect here for
embedding or de-embedding
RS 232 data.
RS 232
TX
LED (yellow) indicates
outgoing serial data at the
RS 232 output
LED ON
=
serial data is sent
RS 232
RX
LED (yellow) indicates
incoming serial data at the
RS 232 input
LED ON
=
serial data is received