2.  IIggnniittiioonn.. Turn the ignition on, then back off: (The H1/9 YELLOW wire must

be connected.)

3.  SSeelleecctt   aa   M

Meennuu.. Press and HOLD the Valet/Program switch: (The

Valet/Program switch must be plugged into the blue port.) After three seconds
the siren will chirp once indicating entry to the Basic Features Menu #1. If this
is the menu you wish to access, release the button and go on to Step 4. If the
button is not released, you will jump to the Advanced Features Menu #2 and
the siren will chirp twice. Once you have selected the desired menu, release the
Valet/Program button and then proceed to Step 4.

4. SSeelleecctt   aa   FFeeaattuurree..   Press and release the Valet/Program switch the number of

times corresponding to the feature you wish to change. For example, to access
the third feature, press and release the switch three times. Then press the switch
once more and HOLD it. The siren will chirp the number of times equal to
the step you have accessed.

5. PPrrooggrraam

m  tthhee  FFeeaattuurree..  While HOLDING the Valet/Program switch, you can

toggle the feature on and off using the remote transmitter. Pressing 
will select the one chirp setting. Pressing 

will select the two chirp

setting. (See 

System Features Menus

section of this guide.) 

NOTE: The Valet pulse count feature (2-5) and the Channel three timed
output (2-9) have five possible settings each. Pressing 

will toggle through

all the two-chirp settings.

6.  R

Reelleeaassee  tthhee  V

Vaalleett//PPrrooggrraam

m  SSw

wiittcchh..

Once a feature is programmed:

Other features can be programmed within the same menu.

Another menu can be selected.

The learn routine can be exited if programming is complete. 

Summary of Contents for Viper 350HV

Page 1: ...ded for installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in severe damage to a vehicle s electrical system a...

Page 2: ...are all Trademarks or Registered Trademarks of Directed Electronics Inc The Bitwriter p n 998T requires chip version 1 4 or newer to program this unit w ww ww w d di ir re ec ct te ec ch hs s c co om...

Page 3: ...ei iv ve er r L Le ea ar rn n R Ro ou ut ti in ne e 2 21 1 T Tr ra an ns sm mi it tt te er r C Co on nf fi ig gu ur ra at ti io on ns s 2 23 3 Standard Configuration 23 Expanded Configuration 23 D Di...

Page 4: ...eases as soon as the system is disarmed The orange wire is pre wired to control the 8618 starter kill relay It can supply up to 500 mA of current NOTE If using the H1 1 ORANGE wire to activate an add...

Page 5: ...Toyota Lexus BMW some Mitsubishi some Mazda and other models NOTE For parking light systems that draw 10 amps or more the jumper must be switched to a light flash output see the Programming Jumpers se...

Page 6: ...c co on nd d t ti im me ed d output will send a signal for 30 seconds when channel three is pressed This output can be shut off during the 30 second period by pressing Channel 3 again This output can...

Page 7: ...f H1 6 BLUE instant trigger input This input will respond to a negative input with an instant trigger It is ideal for hood and trunk pins and will report on Zone 1 It can also be used with Directed si...

Page 8: ...ptable ground points It is recommended that all security components be grounded at the same location H1 9 YELLOW ignition input Connect this wire to the 12 volts ignition wire This wire is pre wired t...

Page 9: ...ose This fuse protects the module itself H1 12 RED WHITE 200 mA channel 2 output When the system receives the code controlling channel 2 for longer than 1 5 seconds the RED WHITE will supply an output...

Page 10: ...ht LED operates at 2 volt DC and plugs into the two pin WHITE port Make sure the LED wires are not shorted to ground as the LED will be damaged Multiple LED s can be used but they must be wired in ser...

Page 11: ...functions For more infor mation please refer to the guide packaged with the programmer This port can also be used to interface with Directed Video components for on screen security system programming...

Page 12: ...ensor does not work well when mounted firmly to metal we do not recommend screwing down the control module The full trigger of the on board shock sensor reports Zone 2 See Table of Zones section of th...

Page 13: ...g Jumper Light Flash Jumper This jumper is used to determine the light flash output In the position the on board relay is enabled and the unit will output 12V on the WHITE wire H1 2 In the position th...

Page 14: ...e number of steps they have been broken up into two menus It is possible to access and change any of the feature settings using the Valet Program switch However this process can be greatly simplified...

Page 15: ...es corresponding to the feature you wish to change For example to access the third feature press and release the switch three times Then press the switch once more and HOLD it The siren will chirp the...

Page 16: ...hen press it once more and HOLD it The siren would chirp seven times to confirm access to the seventh feature To select another menu 1 Press and HOLD the Valet Program switch 2 After three seconds the...

Page 17: ...lse Double unlock pulse 2 9 Single lock pulse Double lock pulse 2 10 Channel 3 Validity Channel 3 latched latched reset with ignition 30 second timed second unlock output 2 11 Comfort Closure On 20 se...

Page 18: ...isplay separate steps for ignition lock and ignition unlock They can be programmed on or off independently 1 4 ACTIVE PASSIVE LOCKING If passive arming is selected in step 1 1 then the system can be p...

Page 19: ...ve and the sensors are bypassed The door triggers will remain active If programmed to the Vehicle Recovery System VRS setting VRS will be activated 1 10 CODE HOPPING ON OFF The system uses a mathemati...

Page 20: ...trigger is programmed off the full siren output will occur the moment the door is opened 2 5 VALET PULSE COUNT ONE TO FIVE PULSES The system can be programmed to count the number presses of the valet...

Page 21: ...e windows when the system is armed A 20 second output starts 200mS after the last lock pulse The Comfort Closure output will be canceled if the unlock button is pressed If programmed the lock output w...

Page 22: ...6 are used to assign the arm disarm and panic functions to separate buttons on the remote control Teaching a button to Channel 5 or Channel 1 erases some information about that remote from memory and...

Page 23: ...Auto Learn functions in the Transmitter Receiver Learn Routine Standard Configuration When programmed for standard configuration the transmitter buttons are assigned to the following functions operate...

Page 24: ...cannot be accessed from a standard configuration transmitter Diagnostics The system s microprocessor monitors and reports all active and violated zones when arming and disarming LED flashes indicate t...

Page 25: ...k pins 2 On board shock sensor Heavy impact detected by the on board shock sensor 3 Two stage progresses from Door switch circuit H1 5 GREEN or H1 7 VIOLET warning to full alarm 4 Multiplexed Input BL...

Page 26: ...urity Arming Multi Level Security arming allows the operator to select which inputs and sensors are active during a particular arming cycle For a full description of Multi Level Security Arming operat...

Page 27: ...tion key on and off to clear the NPC from memory and then retest the shock sensor For a detailed description of NPC see Owner s Guide Door input does not immediately trigger full alarm Instead I hear...

Page 28: ...cating the sensor can often solve this problem If the LED indicates that the door caused the trigger you may have programmed the progressive door trigger off See Feature 2 4 in the Feature Description...

Page 29: ...2005 Directed Electronics Inc all rights reserved 29 Wiring Quick Reference Guide...

Reviews: