10
© 2000 Directed Electronics, Inc. Vista, CA
(-) Light Flash Output
NOTE:
For parking light circuits that draw 10 amps or more, the internal jumper must be switched
to a (-) light flash output. (See the Internal Programming Jumper section of this guide.)
P/N 8617
or a standard automotive SPDT relay must be used on the H1/2 light flash output harness wire.
Sending a negative pulse to this wire will initiate the remote start sequence. This wire can be wired to an optional
momentary switch to activate the remote start system.
Connect this wire to the optional domelight supervision relay as shown below:
IMPORTANT!
This output is only intended to drive a relay. It cannot be connected directly to the
domelight circuit because the output cannot support the current draw of one or more light bulbs.
H1/4 BLACK /WHITE (-) 200 mA domelight supervision output
H1/3 WHITE/BLUE (-) activation input