13
© 2011 Directed Electronics. All rights reserved.
Menu 2 - Convenience
Menu
Item
Feature
Opt. 1
Opt. 2
Opt. 3
Opt.4
Opt. 5+
1
One-time Bypass
No Bypass
Bypass
2
Override Pulse Count
1
2
3
4
5
3
Door Open Error chirp*
On
Off
4
Ign-controlled Dome light
On
Off
5
OEM Alarm Disarm w/Aux/
trunk
On
Off
6
OEM Alarm Disarm Output
With Unlock
Before Unlock
Remote Start
Only
7
OEM Alarm Disarm Pulses
1
2
8
Aux 1 Output type
Validity
Latch
Latch/reset/
ign
Timed
Off (5)/2nd
Unlock (6)
9
Aux 1 Linking
No Linking
Link to Lock
Link to Unlock
Link to Lock/
Unlock
Link to Remote
Start only
10
Aux 2 Output type
Validity
Latch
Latch reset/ign Timed
Off (5)/2nd
unlock (6)
11
Aux 2 Linking
No Linking
Link to Lock
Link to Unlock
Link to Lock/
Unlock
Link to Remote
Start only
12
Aux 3 Output type
Validity
Latch
Latch reset/ign Timed
Off (5)/2nd
unlock (6)
13
Aux 3 Linking
No Linking
Link to Lock
Link to Unlock
Link to Lock/
Unlock
Smart Key
Control (Link to
Remote Start
Off)*
14
Aux 4 Output Type
Validity
Latch
Latch reset/ign Timed
Off (5)/2nd
Unlock (6)
15
Aux 4 Linking
No linking
Link to Lock
Link to Unlock
Link to Lock/
Unlock
Link to Remote
Start Only
16
Aux/Trunk Output type
Validity
Off
2nd unlock
*
The Green H2/6 or the Violet H2/12 wire must be connected to enable this feature.
1. One-time Bypass
1. Off: One-Time Bypass is not available
2. On: the One-Time Bypass feature will defeat Passive Locking once and, if Locked by remote control,
will defeat Comfort Closure and Aux outputs linked to Locking
2. Override Pulse Count
•
1-5: sets the number of presses (1-5) on the Control Button required to override the alarm system
3. Door Open Error chirp
1. On: if the door trigger is active when locking, the horn will emit a honk and a message will be sent
to the 2way remote control as an alert
2. Off: an active door trigger when locking will not create an alert output
4. Ign-controlled Dome light
1. On: the dome light output will activate when the ignition is turned off
2. Off: the dome light output will not activate when the ignition is turned off
5. OEM Alarm Disarm w/Aux/Trunk (H2/4 wire)
1. On: the OEM Alarm Disarm wire will pulse as programmed when the Aux/Trunk output is activated
2. Off: the OEM Alarm Disarm wire will not pulse when the Aux/Trunk output is activated
6. OEM Alarm Disarm Output (H2/4 wire)
1. With Unlock: the OEM Alarm Disarm wire will pulse as programmed at the same time as the unlock
(Blue) wire