If the bypassed sensor tries to trigger the system while it is being
bypassed, the 60-minute bypass period will start over. This en-
sures that a sensor that continually triggers will remain bypassed.
Doors are covered by NPC differently; if the alarm is triggered
by an open door for three full cycles, the doors will be bypassed
until the trigger ceases.
Arming and disarming the system does not reset this function!. The
only ways to reset a bypassed zone are for it to not trigger for 60
minutes, or to turn on the ignition. If testing your system, it is impor-
tant to remember that the NPC programming can cause zones to
be bypassed and appear to stop working. If fve chirps are heard
when disarming, NPC has been engaged. If you wish to clear the
NPC memory, turn the ignition key on.
NPC is programmable. See Programming Options section of this
guide.