PP8 Plus
20
IN50001 Rev. C 04/30/2008
Cable Inspection Guide
Maximum Allowable Cable Necking
Nom. Cable Diameters Max. Reduction in Diameter
Up to 5/16”
1/64”
3/8” to 1/2”
1/32”
9/16” to 3/4”
3/64”
7/8” to 1-1/8”
1/16”
1-1/4” to 1-1/2”
3/32”
Typical
Good
Cable
Cable
With
Broken
Wires
Cable With Severe Corrosion
Cable With Necking
Daily Inspection & Maintenance
1. Cleanliness: Cables, Columns, Runways and other lift parts should be kept free of
corrosive agents, solvents, and road salts. If such agents are spilled or splashed on any lift
component, immediately rinse thoroughly with water and wipe down with a clean rag. Spray
wire rope cables as required with Penetrating Oil and wipe down.
Failure to keep lift free of corrosive agents and solvents will lead to reduced component
service life, cable failure, etc., which could result in property damage and/or personal injury.
2. Fasteners: Check all the attaching bolts and nuts for tightness.