INSTRUCTIONS FOR USE DA 270, DA 370, DA 280, DA 380
UM_EN_DA270_DA280_DA370_DA380_m2015_2019-04_ver1.9 15 / 67
Current time and date
12.AUG 12:12
Time and date can be set in user menu
Alarm
It serves to warn the dentist. It has the function of timer.
The time is adjustable. Press the button to display menu with available times. One of them marked with U can
be set in the user menu. By pressing the button with desired time the time starts to count down to zero value
by 1 second. By repeated pressing of the button during countdown the timer function is cancelled. When the time at
countdown reaches 00:00, an audible signal sounds.
Light
It has three basic level of intensity:
Switched off
Lowered intensity of illumination
for work with photocomposites
Standard intensity
Press the button to alternate between the individual levels of illuminance.
Bowl rotation
– to working position, programming.
Press and hold the button for more than 1 second, the bowl will rotate until the button has been released and the
rotation time is saved into the memory automatically. Press the button for less than 1 second to shift the bowl to
programmed position. If the bowl is shifted when the button is pressed, it returns to its starting position. To interrupt
the bowl running, press the button for less than 1 second. (Valid only for the bowl with powered drive).
Bowl flushing
Press and hold the button for more than 2 seconds
– the bowl is being flushed until the button has been released
and the flushing time is saved in the memory automatically. To start the flushing for the time saved in the memory,
press the button briefly. To stop the flushing during the flushing time, press the button briefly; the time saved in
the memory is not changed. The flushing starts automatically also after the bowl has returned to zero position. Automatic
starting of bowl flushing can be turned on/off in the user menu.
Cup filling
Press and hold the button for more than 2 seconds
– the cup is being filled until the button has been released
and the filling time is saved in the memory automatically. To start the filling for the time saved in the memory,
press the button briefly. To stop the filling during the filling time, press the button briefly; the time saved in the
memory is not changed.
Turning the negatoscope on/off
Press the button to increase brightness of the display backlight to 100%, place the negative and fix it with the
magnetic clip furnished. To cancel the function, press the button again and the brightness will return to previous
level. The negatoscope can be turned on when an instrument is taken.
If a picture is selected from inserted and recognized USB key by means of USB menu, then the said picture is displayed
instead of white background.
Bell
Press and hold the button to switch the relay of the bell in the spittoon block.
User
Displayed information about the current user. Selection of four users is available, i.e. data for four users is
stored in the memory. By pressing the button a pop-up menu is displayed with potential users.
To select the user, press the respective button. User name can be edited in the user menu. After the desired item has
been pressed the display is reset and the parameters are set for the selected user.