SIP Server Address (the IP address of the Elastix Server,
‘
172.16.33.58
’
in this example)
SIP Server Port (5060 in this example)
Is Register (Select No, as it is IP Trunking instead of SIP registration)
Step 3.
Click Save on the bottom of the interface.
Step 4.
On the navigation tree on the right, click System Configuration
Port Parameter, and
configure authentication information on the interface.
SIP User ID: the username set in Step 3 of the configuration on Elastix Server.
Authenticate ID: Same as SIP User ID by default
Authenticate Password: the secret set in Step 3 of the configuration on Elastix Server.
To VOIP Hotline: the inbound number that is dialed automatically by the DWG2000-1G when
‘
Auto Call
’
is selected in the Operation
Tel-> IP Operation interface (make reference to 6.5.2)
To PSTN Hotline: the outbound number that is dialed automatically by the DWG2000-1G when
‘
Auto Call
’
is selected in the Operation
IP-> Tel Operation interface (make reference to 6.5.1)
Step 5.
In the navigation tree, click Routing Configuration
IP->Tel Routing, and modify the default
IP ->Tel route.