![DINSEO DIX TIG GO 1906.M HF Operation Manual Download Page 23](http://html1.mh-extra.com/html/dinseo/dix-tig-go-1906-m-hf/dix-tig-go-1906-m-hf_operation-manual_2505866023.webp)
23
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T7) down for about
1 second
.
3D - SYN PULSE + SWITCH
Press the PULSE key (T3) until the requited
pulsation is active (SYN LED on).
Press the WELDING MODE SELECTION key
(T6) until the SWITCH welding mode is active
(SWITCH LED on).
Press the WELDING PARAMETERS SELEC-
TION Key (T7) a number of times to set the
following (in addition to the WELDING PARA-
METERS defined as being “BASIC”):
L10 L18
L21
T7
L10
-
L20
1
st
LEVEL PEAK CURRENT I
1p
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
WARNING: When the SYN PULSE function is active, the 1
st
level
PEAK CURRENT ( I
1p
) is regulated to achieve a synergy with the
values for the other 1
st
level parameters ( I
1b
, f ).
L18
2
nd
LEVEL PEAK CURRENT I
2p
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
WARNING: When the SYN PULSE function is active, the 2
nd
level
PEAK CURRENT ( I
2p
) is regulated to achieve a synergy with the
values for the other 2
nd
level parameters ( I
2b
, f ).
If you want to do a test weld, during the test the LED for the
parameter selected flashes and the DISPLAY shows the value for
the parameter you are setting.
To exit the setting phase, hold the WELDING PARAMETERS
SELECTION key (T7) down for about
1 second
.
NOTE: During the welding process if LED I
p
and LED I
1
stay
switched on on the DISPLAY, the 1
st
level current at which you
are welding is displayed.
NOTE: During the welding process if LED I
2
and LED I
p
stay
switched on on the DISPLAY, the 2
nd
level current at which you
are welding is displayed.
SPECIAL CONFIGURATION (SPE)
During TIG welding with HF ignition, the units allow you to further
modify the WELDING PARAMETERS, thereby providing a more
skilled welder and a more versatile welding power source.
Activation will only take place after the welding power source
configuration is changed from STANDARD (Std) to SPECIAL
(SPE), which must be done as follows:
1) When the welding power source is off, push and hold the
“PRG” PROGRAM key down (T2).
2) Start the welding power source by turning the power supply
switch to position
I
.
3) The DISPLAY (D) shows the following message:
Std
(welder
configured in STANDARD mode).
4) Turn the ENCODER Key (E) until the DISPLAY (D) shows
the following message:
SPE
(welder configured in SPECIAL
mode).
PULSE
SYN
FAST
SLOW
T3
T6
PULSE
SYN
FAST
SLOW
D
E
T2
5) Press the “PRG” PROGRAM key (T2) to confirm.
The
WELDING PARAMETERS
included, that can be programmed
and changed (by turning the ENCODER knob) in the
SPECIAL
(SPE)
configuration, along with those in the STANDARD con-
figuration, can be set by pushing the WELDING PARAMETER
SELECTION button (T7) successively:
L8
L17
L21
T7
L8
IGNITION CURRENT
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
WARNING: This can only be programmed when the TIG with HF
ignition welding process is used.
WARNING: If the value for this parameter is too low, ignition pro-
blems may arise.
L17
IGNITION welding CURRENT
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
WARNING: Only programmable for the welding process: TIG with
HF ignition and 2 TIME welding mode active.
L21
FINAL welding CURRENT
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
WARNING: Only programmable for the welding process: TIG with
HF ignition and 2 TIME welding mode active.
To exit the setting phase, hold the WELDING PARAMETERS
SELECTION key (T7) down for about
1 second
.
WARNING: These WELDING PARAMETERS are only to be acti-
vated by qualified personnel, or those trained by technicians.
Summary of Contents for DIX TIG GO 1906.M HF
Page 5: ...5 FIG A ...
Page 10: ...10 Wiring diagram DIX TIG GO 1906 M HF ...
Page 11: ...11 2101WA31 ...
Page 12: ...12 Wiring diagram DIX TIG GO 2506 M HF ...
Page 13: ...13 2101WB24 ...