7
AC recovery
(
6
)
Energy-saving switch
1) "ON"
When energy-saving switch is switched to
"ON" position, the device controls engine
speed based on the load connected, thus very
good fuel consumption and low noise can be
obtained.
2) "OFF"
When the energy-saving switch is set to the "OFF" position, the engine will
run at rated speed, regardless of whether being connected to a load.
Tip:
When using following devices, such as air compressor and submersible
pump, the energy-saving switch must be in "OFF" position, because it
requires great startup current.
(
7
)
Fuel tank cap
Remove fuel cap by unscrewing it counterclockwise.
(
8
)
AC recovery
When the output is overloaded, the generator will protect automatically to
output no voltage. Reduce the load, press the AC recovery switch, and the
generator will resume output.
(
9
)
Grounding terminal
Grounding terminal shall be connected to grounding wire to prevent electric
shock. When an electrical equipment is grounded, the generator must be
grounded.