background image

 

28

 

1 4 )

 

After the failure occurs, the buyer failed to maintain original condition of 

the damage or handled it by self without obtained the consent the seller 

or repairer, to make it impossible to make a technical identification of the 

cause of failure.  

1 5 )

 

The  user  has  no  Three  Guarantees  Certificate  or  valid  invoice,  or  the 

model on the Three Guarantees Certificate does not match actual model, 

or there is any sign of alteration (except that it can prove that the product 

is within the warranty).  

1 6 )

 

Gasoline engines used in contest are not covered by the warranty.  

Disclaimer

 

 

1 )

 

The user is responsible for all kinds of indirect costs caused due to the 

repair.  

2 )

 

The Company shall not be responsible for any inconvenience or loss 

caused due to that the machine is unable to be used (such as the loss 

from suspension of business or business loss, etc.).  

3 )

 

The  Company  shall  not  be  responsible  for  any  loss  caused  by  the 

earthquake, typhoon, flood, fire and other force majeure factors.  

Precautions

   

The "Three Guarantees Certificate" in the "User's Manual" is in three pages, 

of  which  Page _ shall be  filled  in  by the  user  when  purchasing  the product, 

which will be collected by the dealer and returned to the Company.  

 

 

 

 

 

 

 

 

Summary of Contents for DK3300i

Page 1: ...INVERTER GENERATOR User s Manual Kindly Remind Please read this User s Manual carefully before using to operate it under the premise of ensuring the safety and environmental protection...

Page 2: ...Due to the revision and other changes contents of this Manual may be slightly different from actual situation The Company is entitled to revise it at any time and the revised version will be developed...

Page 3: ...rol Functions 5 IV Preparations 8 V Starting up the Generator 10 VI Shutting Down the Generator 10 VII Using the Generator 11 VIII Service and Maintenance 16 IX Storage and Transport 22 X Troubleshoot...

Page 4: ...rning there is one of four words DANGER WARNING ATTENTION and CAREFUL Details are as follows DANGER Failure to follow the instruction will result in being in peril of your life or extremely serious in...

Page 5: ...2 I Safety Instructions Before operating the generator it will help you avoid accidents to read and understand the Manual and familiarize yourself with the safe operation procedures of the generator...

Page 6: ...Names of Components Lifting handle Knob Leftenclosure Fuel tank cap Control panel Startup handle Spark plug cover plate Side shield of muffler Right enclosure Air filter cover plate Oil cover plate Mu...

Page 7: ...el Idle switch Oil alarm indicator Overload indicator AC output indicator DC cigarette lighter socket AC resume switch AC socket DC socket USB socket DC protection Earthing terminal Three in one combi...

Page 8: ...choke switch 2 Oil indicator red When the oil in the crankcase drops below safety line oil protection system will automatically shut down the engine and oil alarm indicator lights up the engine can be...

Page 9: ...electrical equipment with high starting current such as compressors submersible pump etc the overload indicator may start to light up for a few seconds at the beginning but this is not the failure men...

Page 10: ...ollowing devices such as air compressor and submersible pump the energy saving switch must be in OFF position because it requires great startup current 7 Fuel tank cap Remove fuel cap by unscrewing it...

Page 11: ...must be used as leaded gasoline can seriously damage internal parts of the generator Remove fuel tank cap and add gasoline to red horizontal indicating line oil level Fuel tank capacity 4L 2 Oil No o...

Page 12: ...arefully Tip The condition of the generator shall be inspected before using every time Pre operation inspection Fuel Check fuel level in fuel tank of the generator and fuel it if necessary Oil Check o...

Page 13: ...status eration Choke valve Tip When hot engine is started up it is unnecessary to close the choke valve but turn the combination switch to RUN 5 First gently pull startup handle until guy cable is hoo...

Page 14: ...bout 2 Every 30 of increase in relative humidity of air will reduce the power of generator by about 1 5 Every 300 m rising of ASL will reduce the power the generator by about 4 5 2 Generator wiring Wh...

Page 15: ...TTENTION Make sure that all electrical equipment including wires and plugs are in good condition before connecting to the generator Make sure that all loads driven by the generator are within rated lo...

Page 16: ...l equipment start from large to small according to the size of each electrical equipment 3 Generator grounding In order to prevent any damage to the generator caused by electric shock or improper elec...

Page 17: ...erator is started up connect the battery to the generator Before charging make sure that DC protector has been switched on Start up the generator Connect red conductor of the battery to positive termi...

Page 18: ...and never connect or disconnect the connection to the battery during charging The spark generated will ignite gas around the battery Battery electrolyte contains sulfuric acid which is toxic and with...

Page 19: ...ower amount shall not exceed rated output power When total power exceeds rated power overload indicator will light up VIII Service and Maintenance Good maintenance and service is the best guarantee fo...

Page 20: ...f ecessary Cylinder head piston Remove carbon deposit Displacement 225cc every 125 hours displacement 225cc every 250 hours These items shall be replaced if necessary These items shall be maintained b...

Page 21: ...sness and even death 1 Spark plug inspection Spark plug is an important part of the generator which must be inspected regularly Remove decorative cover and spark plug cap of the generator Insert the s...

Page 22: ...oil WARNING Do not drain the oil immediately after turning off the generator Oil temperature is very high when operating take care to avoid scalding 1 Place the generator on a horizontal plane surfac...

Page 23: ...lean foam cleaner element with cleaning solvent and blow it dry 5 Drip a few drops of oil to foam filter element and squeeze off excess oil The foam cleaner element shall be wet but there shall not be...

Page 24: ...el filter screen WARNING Be sure not to open fuel tank of the generator in a place where smoking or with flame 1 Remove fuel tank cap and fuel tank filter screen 2 Clean fuel tank filter screen with g...

Page 25: ...in the carburetor into special fuel tank 6 Turn three in one switch to OFF 7 Tighten fuel drain bolt 8 Assemble right enclosure back and tighten bolts 9 After the engine is completely cooled switch o...

Page 26: ...tch on engine switch running 2 Bad spark 3 The spark plug is stained with carbon deposit and moisture Remove carbon deposit and wipe spark plug dry 4 Bad ignition system Enquiry your agency shop for s...

Page 27: ...el tank volume L 4L 3 7L Fuel type and grade Vehicle use unleaded gasoline Lubricating oil capacity 0 35 0 45 Lubricating oil model SAE 10W 30 SAE 10W 30 Lubrication mode Splash lubrication Splash lub...

Page 28: ...nel part Brown_ _ Brown AC outlet _Brown_ AC indicator Overload indicator DC socket USB _socket Flameout switch Oil warning indicator Ignition coil Spark plug Stepper motor Ignition winding Secondary...

Page 29: ...r Normal wearing components various plugs switches pulling cords oil filter elements air cleaner elements fuel filter elements filters oil seals water seals piston rings spark plugs carbon brushes fus...

Page 30: ...maximum engine speed etc 5 The product is damaged caused due to the failure of using genuine accessories supplied by the Company 6 The product is damaged caused due to the failure of using oil or gaso...

Page 31: ...asoline engines used in contest are not covered by the warranty Disclaimer 1 The user is responsible for all kinds of indirect costs caused due to the repair 2 The Company shall not be responsible for...

Page 32: ...Signature of repair personne Signature of the customer 2 Service life Time of returning for repair Receiving time Signature of repair personne Signature of the customer 3 Service life Time of returnin...

Page 33: ...by the authorized maintenance station and Page 3 is shall be kept by the user 2 In principle the user s contact telephone No is given priority to fixed line phone No If the user has both fixed line an...

Page 34: ...y the authorized maintenance station and Page 3 is shall be kept by the user 2 In principle the user s contact telephone No is given priority to fixed line phone No If the user has both fixed line and...

Page 35: ...kept by the authorized maintenance station and Page 3 is shall be kept by the user 2 In principle the user s contact telephone No is given priority to fixed line phone No If the user has both fixed li...