8
6.5 TOTALISATION OF THE WEIGHT
The scale can be set to accumulate manually the weight on the scale by pressing the
PRINT/M+
key (see step “AU”,
chapter 7.1).
The weight displayed will be stored in memory when the
PRINT/M+
key is pressed and the weight is stable.
The display will show "ACC 1" while the weight will be printed, then the total in memory for 2 seconds before returning
to normal.
Remove the weight, allowing the scale to return to zero and put a second weight on. Press the
PRINT/M+
key, the
display will show " ACC 2" and then the new total.
Continue until all weights have been added.
To view and print the totals in memory press
PRINT/M+
key when current scale in zero status (Zero indicator on)
To clear the accumulated total weight, press the
PCS
key when show total values.
Scale automatically exit form the visualization of the total values after few seconds.
NOTE:
-
The totalisation functions with a minimum weight of 20d.
-
The maximum number of totalisations is 999 while the maximum total value which may be accumulated is
999999.
Once reached these limits, one should clear the total; by pressing
PRINT/M+
the message “AdErr” will appear on
the display.
-
The total values will be cleared when it’s turned off.
6.5.1 MANUAL OR AUTOMATIC TOTALIZATION
The operation of accumulation, normally done manually with key
PRINT/M+
, can be done automatically when the
weight is stable. In regards to the choice of the totalisation execution mode, see step “AU”, section 7.1.
6.6 COUNTING PIECES
Through the reference function it’s possible to use the scale as a piece counter.
COUNTING PROCEDURE
The operations to be carried out are the following:
1)
Place the empty container on the scale and press
TARE
to tare it.
2)
Check that the zero is on the display and put the quantity of pieces chosen for the SAMPLE on the scale and
press
PCS
key
.
3)
The display suggests a REFERENCE QUANTITY. The possible options are: 10, 20, 50, 100, and 200.
4)
Press
TARE
the number of times needed to reach the desired sample size.
5)
Press
ZERO
; the display will indicate "- - - - - -" and the indicator will calculate the
A
verage
P
iece Weight (
APW
).
After a few instants the display will indicate the quantity selected put on the platform.
6)
Add the rest of the items to count in the container and whose value will appear on the display.
7)
Unload the scale, the APW will remain stored in memory for the next counting of similar pieces, without having to
repeat the REFERENCE operation.
8)
By pressing the
MODE
key one switches from the display of the number of pieces to the display of the average
piece weight and of the net weight.
9)
Per cancel or to carry out a new reference operation
, press the
PCS
key and repeat the operations as
describe in point
1).