Dini Argeo HLD Series Operating Manual Download Page 7

 

8

6.5 TOTALISATION OF THE WEIGHT 

 
The scale can be set to accumulate manually the weight on the scale by pressing the

 PRINT/M+

 key (see step “AU”, 

chapter 7.1). 
 
The weight displayed will be stored in memory when the 

PRINT/M+

 key is pressed and the weight is stable. 

 
The display will show "ACC 1" while the weight will be printed, then the total in memory for 2 seconds before returning 
to normal. 
 
Remove the weight, allowing the scale to return to zero and put a second weight on. Press the 

PRINT/M+

 key, the 

display will show " ACC 2" and then the new total. 
 
Continue until all weights have been added. 
 
To view and print the totals in memory press 

PRINT/M+

 key when current scale in zero status (Zero indicator on) 

To clear the accumulated total weight, press the 

PCS

 key when show total values. 

Scale automatically exit form the visualization of the total values after few seconds. 

 

NOTE: 

The totalisation functions with a minimum weight of 20d. 

The  maximum  number  of  totalisations  is  999  while  the  maximum  total  value  which  may  be  accumulated  is 
999999. 
Once reached these limits, one should clear the total; by pressing 

PRINT/M+

 the message “AdErr” will appear on 

the display. 

The total values will be cleared when it’s turned off. 

 
 
6.5.1 MANUAL OR AUTOMATIC TOTALIZATION 

The  operation  of  accumulation,  normally  done  manually  with  key 

PRINT/M+

,  can  be  done  automatically  when  the 

weight is stable. In regards to the choice of the totalisation execution mode, see step “AU”, section 7.1. 

 
6.6 COUNTING PIECES   

Through the reference function it’s possible to use the scale as a piece counter. 

 
COUNTING PROCEDURE 

The operations to be carried out are the following: 

1)

  Place the empty container on the scale and press 

TARE

 to tare it.   

2)

  Check that the zero is on the display and put the quantity of pieces chosen for the SAMPLE on the scale and 

press

 PCS 

key

.

 

3)

  The display suggests a REFERENCE QUANTITY. The possible options are: 10, 20, 50, 100, and 200. 

4)

  Press 

TARE

 the number of times needed to reach the desired sample size.   

5)

  Press 

ZERO

; the display will indicate "- - - - - -" and the indicator will calculate the 

A

verage 

P

iece Weight (

APW

). 

After a few instants the display will indicate the quantity selected put on the platform. 

6)

  Add the rest of the items to count in the container and whose value will appear on the display.   

7)

  Unload the scale, the APW will remain stored in memory for the next counting of similar pieces, without having to 

repeat the REFERENCE operation.   

8)

  By pressing the 

MODE

 

key one switches from the display of the number of pieces to the display of the average 

piece weight and of the net weight. 

9)

 

Per cancel or to carry out a new reference operation

, press the 

PCS 

key and repeat the operations as 

describe in point 

1). 

 

 

Summary of Contents for HLD Series

Page 1: ...RWAAGE BALANCE POUR LABORATOIRES BILANCIA DA LABORATORIO HLD OPERATING MANUAL Industrial Weighing Systems 9 Richmond St Picton Ontario Canada K0K 2T0 www iwsystems ca e mail info iwsystems ca HLD_V1 0...

Page 2: ...ATION OF THE WEIGHT 8 6 5 1 MANUAL OR AUTOMATIC TOTALIZATION 8 6 6 COUNTING PIECES 8 6 7 SAMPLE WEIGHT PERCENTILE 9 6 8 UNIT OF MEASURE CONVERSION 9 6 8 1 SECONDARY UNITS OF MEASURE 9 7 SET UP ENVIRON...

Page 3: ...y are not in use 2 MAIN TECHNICAL SPECIFICATIONS Model Plate dimensions mm Capacity g Standard Division g HR Division g Linearity g Internal sensitivity g Min APW recommended g HLD150 80mm 150 0 02 0...

Page 4: ...is advisable to completely recharge the battery 12 hours with the first installation of the instrument TO POWER the instrument through the 240 Vac mains put the AC DC power plug in the appropriate so...

Page 5: ...matic tare A secondary function of incrementing the active digit or selecting a value or parameter when in setting mode If pressed for an instant it allows linking a weight to the 100 percentile see s...

Page 6: ...orm a value for its weight will be displayed Press the TARE key to tare the scale when the stable is light The weight that was displayed is stored as the tare value and that value is subtracted from t...

Page 7: ...N The operation of accumulation normally done manually with key PRINT M can be done automatically when the weight is stable In regards to the choice of the totalisation execution mode see step AU sect...

Page 8: ...t name Conversion g 1 g gram 2 g gram weight x 10 high resolution 3 ct net carat 0 2g 4 lb lb 453 59237g 5 oz ounce 28 349523125g 6 d dram 1 7718451g 7 ozt troy ounce 31 1034768g 8 dwt penny weight 1...

Page 9: ...ion 6 8 enabling on or disabling oFF the suggested secondary units of measure 1 The display proposes the first secondary unit of measure to be enabled or disabled 2 Press MODE to change the options an...

Page 10: ...password To enter the menu press the PCS M and TARE keys one after the other The display shows the first parameter P1 Lin IN CASE THE ZONE OF USE IS DIFFERENT FROM THE CALIBRATION ZONE ONE SHOULD 1 Se...

Page 11: ...POINTS By pressing ZERO the instrument shows the A D converter points relative to the weight on the scale Press PRINT M to exit the step P4 AZ ZERO TRACKING By pressing ZERO one sets the divisions num...

Page 12: ...ccumulating the weight the data format is the following When the totals are recalled from the storage the data format is the following Counting Mode In the counting operations when the PRINT M key is...

Page 13: ...t from the scale if it s exceeding The load cell or the electronics could be damaged RECYCLING INSTRUCTION The crossed out wheeled bin on the product means that at the product end of life it must be t...