Dini Argeo HLD Series Operating Manual Download Page 1

 

LABORATORY SCALE 

LABORWAAGE 

BALANCE POUR LABORATOIRES 

BILANCIA DA LABORATORIO 

 

 
 
 
 
 
 
 
 

HLD

 

 
 
 
 
 
 
 

 

OPERATING MANUAL 

Industrial Weighing Systems

9 Richmond St, Picton, Ontario, Canada, K0K 2T0 

www.iwsystems.ca   e-mail  [email protected]

 

 
 
 
 
 

HLD_V1.003_11.06_EN_DE_FR_IT 

Summary of Contents for HLD Series

Page 1: ...RWAAGE BALANCE POUR LABORATOIRES BILANCIA DA LABORATORIO HLD OPERATING MANUAL Industrial Weighing Systems 9 Richmond St Picton Ontario Canada K0K 2T0 www iwsystems ca e mail info iwsystems ca HLD_V1 0...

Page 2: ...ATION OF THE WEIGHT 8 6 5 1 MANUAL OR AUTOMATIC TOTALIZATION 8 6 6 COUNTING PIECES 8 6 7 SAMPLE WEIGHT PERCENTILE 9 6 8 UNIT OF MEASURE CONVERSION 9 6 8 1 SECONDARY UNITS OF MEASURE 9 7 SET UP ENVIRON...

Page 3: ...y are not in use 2 MAIN TECHNICAL SPECIFICATIONS Model Plate dimensions mm Capacity g Standard Division g HR Division g Linearity g Internal sensitivity g Min APW recommended g HLD150 80mm 150 0 02 0...

Page 4: ...is advisable to completely recharge the battery 12 hours with the first installation of the instrument TO POWER the instrument through the 240 Vac mains put the AC DC power plug in the appropriate so...

Page 5: ...matic tare A secondary function of incrementing the active digit or selecting a value or parameter when in setting mode If pressed for an instant it allows linking a weight to the 100 percentile see s...

Page 6: ...orm a value for its weight will be displayed Press the TARE key to tare the scale when the stable is light The weight that was displayed is stored as the tare value and that value is subtracted from t...

Page 7: ...N The operation of accumulation normally done manually with key PRINT M can be done automatically when the weight is stable In regards to the choice of the totalisation execution mode see step AU sect...

Page 8: ...t name Conversion g 1 g gram 2 g gram weight x 10 high resolution 3 ct net carat 0 2g 4 lb lb 453 59237g 5 oz ounce 28 349523125g 6 d dram 1 7718451g 7 ozt troy ounce 31 1034768g 8 dwt penny weight 1...

Page 9: ...ion 6 8 enabling on or disabling oFF the suggested secondary units of measure 1 The display proposes the first secondary unit of measure to be enabled or disabled 2 Press MODE to change the options an...

Page 10: ...password To enter the menu press the PCS M and TARE keys one after the other The display shows the first parameter P1 Lin IN CASE THE ZONE OF USE IS DIFFERENT FROM THE CALIBRATION ZONE ONE SHOULD 1 Se...

Page 11: ...POINTS By pressing ZERO the instrument shows the A D converter points relative to the weight on the scale Press PRINT M to exit the step P4 AZ ZERO TRACKING By pressing ZERO one sets the divisions num...

Page 12: ...ccumulating the weight the data format is the following When the totals are recalled from the storage the data format is the following Counting Mode In the counting operations when the PRINT M key is...

Page 13: ...t from the scale if it s exceeding The load cell or the electronics could be damaged RECYCLING INSTRUCTION The crossed out wheeled bin on the product means that at the product end of life it must be t...