Dini Argeo DFWLKI3GD Manual Download Page 4

DFWLKI3GD  

 

4 di 9 

 

 

All the peripheral units (for instance printers, converters, etc.), which are not marked ATEX, should be installed  
only in a zone which is not ATEX classified. 

 

 

Be very careful when using the instrument; any sparks could cause an explosion. 

 

 

The DFTL remote control IS NOT ATEX3GD certified therefore it can not be used with the indicator. 

 

 

Avoid direct sunlight.

 

 

 

If the indicator is powered through the BP6ATEX3GD battery, it must not be powered through another voltage 
because the battery must not be recharged in the hazardous zone.

 

 
Warning: 

- Read carefully this document and apply the his technical specifications. 
- This manual has been made as carefully and exactly as possible; in any case, your suggestions are always welcome. 
 

 
 

 

2.  DESCRIPTION of the SYSTEM  

 

 

The "DFWLKI3GD”, “ATEX3GD" version, electronic weighing terminal is device for hazardous areas having presence of 

gas, designed and made according to the ATEX 94/9/CE directive, group II category 3GD according to the EN60079-0, 
EN60079-15, EN61241-0 and EN61241-1 norms with the “limited breathing” protection mode (Ex and nR) for the gas and 
with the limitation for the maximum superficial temperature of the case (tD and IP) for the dust. 
 

 

Summary of Contents for DFWLKI3GD

Page 1: ...DFWLKI3GD 1 di 9 WEIGH INDICATOR DFWLKI3GD ATEX3GD VERSION FOR UTILIZATION IN EXPLOSION RISK AREAS ANNEX ...

Page 2: ...NDEX 1 WARNINGS 3 2 DESCRIPTION of the SYSTEM 4 3 MARKINGS 5 4 INSTRUCTIONS FOR INSTALLATION IN DANGEROUS AREA 5 4 1 BP6ATEX3GD EXTERNAL BATTERY OPTIONAL 7 4 1 1 BATTERY REMOVING CHARGING 8 DECLARATION OF CE CONFORMITY 9 ...

Page 3: ...of protection see EN60079 15 Do not tamper with or alter with the instrument s seals cable passings i locking screws tightening In the case of installation or maintenance must be respect the IP65 protection degree and the limited breathing protection mode by closing all the holes with caps and or cable glands for inserting cables in the weight indicator case close well the cap of all the cable gla...

Page 4: ...ery must not be recharged in the hazardous zone Warning Read carefully this document and apply the his technical specifications This manual has been made as carefully and exactly as possible in any case your suggestions are always welcome 2 DESCRIPTION of the SYSTEM The DFWLKI3GD ATEX3GD version electronic weighing terminal is device for hazardous areas having presence of gas designed and made acc...

Page 5: ...case NOTE The equipment also has IP65 protection Hazardous zones Category according to the 94 9 CE directive Gases hazes or vapours Zone 0 1G Gases hazes or vapours Zone 1 1 G or 2G Gases hazes or vapours Zone 2 1 G 2G or 3G Powders Zone 20 1D Powders Zone 21 1 D or 2D Powders Zone 22 1D 2D or 3D 4 INSTRUCTIONS FOR INSTALLATION IN DANGEROUS AREA The equipment must be installed and maintained accor...

Page 6: ...the internal power adapter with the appropriate bracket lock the fairlead cap of the PG cable gland close the indicator making sure that the wires do not get stuck with the front panel s seal and the case tighten the locking screws N B Make sure that the metallic box is closed well before using the indicator To connect the cable coming from the platform or from the load cell s unscrew the indicato...

Page 7: ...DFWLKI3GD 7 di 9 4 1 BP6ATEX3GD EXTERNAL BATTERY OPTIONAL The indicator may be powered trough an external battery optional whose external dimensions are shown in figure ...

Page 8: ...HE BATTERY BEFORE INSTALLING IT IN THE INSTRUMENT THE BATTERY CHARGER MUST ALWAYS BE USED IN A SAFE AREA THE BATTERY CHARGER MUST ONLY BY POWERED BY THE SUPPLIED MAINS ADAPTER AVOID ACCUMULATIONS OF DUST CLEAN ONLY WITH DAMP CLOTH AND OR ANTISTATIC PRODUCTS CHECK THE STATUS OF THE INDICATOR BATTERY CONNECTOR CONNECT THE BATTERY TO THE GROUND USING THE APPROPRIATE ANTI ROTATION AND ANTI LOOSENING P...

Page 9: ...C 2004 108 CE Directive 2006 95 EU Directive ATEX 94 9 CE Directive 2009 23 CE Directive The conformity is confirmed by the observance of the following norms EN 60079 0 2006 EN 60079 15 2005 EN 61241 0 2007 EN 61241 1 2006 EN 1127 1 2007 EN 13463 1 2009 EN 61000 6 2 2005 EN 61000 6 4 2007 EN 61326 1 2006 EN 55011 2007 EN 61010 1 2001 EN 45501 1992 Only with M mark Markings II 3G Ex nR IIC T6 X II ...