1.  WARNINGS 

 

 

The use of the instrument in hazardous areas require a special attention and special precautions during the use and  

Maintenance. 

 

 

Avoid accumulations of dust. 

 

 

ATTENTION! BE CAREFUL OF ELECTROSTATIC CHARGES; ONLY USE WET CLOTHES OR ANTISTATIC 
PRODUCTS  FOR CLEANING 

 

 

The    instrument    complies    for    the    use    in    zones    with    specific    characteristics:    do    not    install    and    use    the  
instrument  in environments different from the foreseen ones. 

 

 

The installation, maintenance and repair of the instrument, must be made by qualified and authorized personnel. 

 

 

The maintenance must be made after removing the voltage/power supply of the instrument. 

 

 

Only spare parts approved by Dini Argeo must be used. 

 

 

Do not paint. 

 

 

The ATEX safety of the weighing system is guaranteed 

only

 if the system is installed, used and taken care of following  

the instructions given in this manual and in the technical manual (

TECH.MAN.REF.

). 

 

 

Avoid accumulations of electrostatic charges; therefore, when using the instrument in a hazardous zone, the appropriate  

work clothing must be used by the operator or the maintenance person. 

 

 

Do not cover the instrument with coverings made by materials which could have electrostatic charge. 

 

 

The safety of the instrument depends on the IP65 protection degree and on the limited breathing case (nR type 

 

of protection, see EN60079-15).   

Do not tamper with or alter with the instrument’s seals (cable passings, i, locking screws tightening).   
In  the  case  of  installation  or  maintenance  must  be  respect  the  IP65  protection  degree  and  the  “limited  
breathing” protection mode by closing all the holes with caps and/or cable glands for inserting cables in the  
weight indicator case: close well the cap of all the cable glands with the relative appropriate cable section, the  

cap of all the wires, the locking screws tightening of the indicator and the various instrument connectors (cell,  
etc.),  using the wrenches having the relative measurement (see the “Instructions for installation in hazardous  
area” section). 

 

 

It  is  forbidden  to  modify  or  repair  the  instrument  with  components  not  conforming  to  the  CE  declaration;  this  
action compromises  the  safety  of  the  instrument  (

with  a  subsequent  loss  of  the  Ex approval

)  and  the  

nullification  of  the product warranty. 

 

 

It is forbidden to connect the instrument to modules not provided for by the CE declaration; this action compromises the 
safety of the instrument (with a subsequent loss of the Ex approval). Contact Dini Argeo srl for further information. 

 

 

It is forbidden to connect the instrument to modules not provided for by the CE declaration; this action compromises the  
safety of the instrument (

with a subsequent loss of the Ex approval

). Contact Dini Argeo srl for further information. 

 

 

All the cables must be installed and protected in accordance with the standard norms for electrical equipment.  

 

Summary of Contents for DFWLKI3GD

Page 1: ...DFWLKI3GD 1 di 9 WEIGH INDICATOR DFWLKI3GD ATEX3GD VERSION FOR UTILIZATION IN EXPLOSION RISK AREAS ANNEX ...

Page 2: ...NDEX 1 WARNINGS 3 2 DESCRIPTION of the SYSTEM 4 3 MARKINGS 5 4 INSTRUCTIONS FOR INSTALLATION IN DANGEROUS AREA 5 4 1 BP6ATEX3GD EXTERNAL BATTERY OPTIONAL 7 4 1 1 BATTERY REMOVING CHARGING 8 DECLARATION OF CE CONFORMITY 9 ...

Page 3: ...of protection see EN60079 15 Do not tamper with or alter with the instrument s seals cable passings i locking screws tightening In the case of installation or maintenance must be respect the IP65 protection degree and the limited breathing protection mode by closing all the holes with caps and or cable glands for inserting cables in the weight indicator case close well the cap of all the cable gla...

Page 4: ...ery must not be recharged in the hazardous zone Warning Read carefully this document and apply the his technical specifications This manual has been made as carefully and exactly as possible in any case your suggestions are always welcome 2 DESCRIPTION of the SYSTEM The DFWLKI3GD ATEX3GD version electronic weighing terminal is device for hazardous areas having presence of gas designed and made acc...

Page 5: ...case NOTE The equipment also has IP65 protection Hazardous zones Category according to the 94 9 CE directive Gases hazes or vapours Zone 0 1G Gases hazes or vapours Zone 1 1 G or 2G Gases hazes or vapours Zone 2 1 G 2G or 3G Powders Zone 20 1D Powders Zone 21 1 D or 2D Powders Zone 22 1D 2D or 3D 4 INSTRUCTIONS FOR INSTALLATION IN DANGEROUS AREA The equipment must be installed and maintained accor...

Page 6: ...the internal power adapter with the appropriate bracket lock the fairlead cap of the PG cable gland close the indicator making sure that the wires do not get stuck with the front panel s seal and the case tighten the locking screws N B Make sure that the metallic box is closed well before using the indicator To connect the cable coming from the platform or from the load cell s unscrew the indicato...

Page 7: ...DFWLKI3GD 7 di 9 4 1 BP6ATEX3GD EXTERNAL BATTERY OPTIONAL The indicator may be powered trough an external battery optional whose external dimensions are shown in figure ...

Page 8: ...HE BATTERY BEFORE INSTALLING IT IN THE INSTRUMENT THE BATTERY CHARGER MUST ALWAYS BE USED IN A SAFE AREA THE BATTERY CHARGER MUST ONLY BY POWERED BY THE SUPPLIED MAINS ADAPTER AVOID ACCUMULATIONS OF DUST CLEAN ONLY WITH DAMP CLOTH AND OR ANTISTATIC PRODUCTS CHECK THE STATUS OF THE INDICATOR BATTERY CONNECTOR CONNECT THE BATTERY TO THE GROUND USING THE APPROPRIATE ANTI ROTATION AND ANTI LOOSENING P...

Page 9: ...C 2004 108 CE Directive 2006 95 EU Directive ATEX 94 9 CE Directive 2009 23 CE Directive The conformity is confirmed by the observance of the following norms EN 60079 0 2006 EN 60079 15 2005 EN 61241 0 2007 EN 61241 1 2006 EN 1127 1 2007 EN 13463 1 2009 EN 61000 6 2 2005 EN 61000 6 4 2007 EN 61326 1 2006 EN 55011 2007 EN 61010 1 2001 EN 45501 1992 Only with M mark Markings II 3G Ex nR IIC T6 X II ...

Reviews: