45
4x0770
Sensor 2 internal code
4 bytes, signed,
read-only
……
……
……
4x0798
Internal code of sensor 16
4 bytes, signed,
read-only
4x0800
Internal code of sensor 17 (new for 21 / 05
/ 30)
4 bytes, signed,
read-only
……
……
……
4x0892
Internal code of sensor 63
4 bytes, signed,
read-only
4x1024
Empty scale code of sensor 1
4 bytes, signed,
read/write
4x1026
Empty scale code of sensor 2
4 bytes, signed,
read/write
……
……
……
4x1054
Empty scale code of sensor 16
4 bytes, signed,
read/write
4x1056
Empty scale code for sensor 17 (new for 21
/ 05 / 30)
4 bytes, signed,
read/write
……
……
……
4x1148
Empty scale code of sensor 63
4 bytes, signed,
read/write
4x1152
Weight of sensor 1 (new for 21 / 05 / 30)
4 bytes, signed,
read/write
……
……
……
4x1276
Weight of sensor 63
4 bytes, signed,
read/write
Appendix Table 1: Modbus RTU function code
Note 1: if the register address is orange, it means that it has been adjusted in
2016. Please check it again before use
Note 2: the maximum number of block read bytes is 120
Note: The register (4x0212) is the panel key number, and writing a number into
this register indicates that a key is pressed, which can be a physical key or an
internal function key. See the following table for details:
serial
number
Schematic
value
Actual
written
value
Corresponding function