OPERATOR
’S MANUAL
with Maintenance Information
Maintenance
49
B-4
Check the Oil Level in the Drive Hubs
Dingli requires that this procedure be
performed every 250 hours or quarterly,
whichever comes
Failure to maintain proper drive hub oil levels
may cause the machine to perform poorly and
continued use may cause component
damage.
1 Before draining oil it is mandatory to rotate
the planetary gear reduction in order to
move the oil plug in filling position, then
loosen the oil plug and wait until the
internal pressure is completely released.
2 Remove the plug located and check the oil
level.
⊙
Result: The oil level should be even with the
bottom of the plug hole.
3 If necessary, remove the plug and add oil
until the oil level.
4 Apply pipe thread sealant to the plug(s),
and then install the plug(s) in the drive
hub.
5 Repeat this procedure for each drive hub.
B-5
Test the Key Switch
Dingli requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
Proper key switch action and response is
essential to safe machine operation. Failure of
the key switch to activate the appropriate
control panel could cause a hazardous
operating situation.
1 Turn the ground red Emergency Stop
button clockwise to the on position. Pull
out the platform red Emergency Stop
button to the on position.
2 Turn the key switch to ground controls.
3 Check any machine function from the
platform controls.
⊙
Result: The machine functions should not
operate.
4 Turn the key switch to platform controls.
5 Check any machine function from the
ground controls.
⊙
Result: The machine functions should not
operate.
6 Turn the key switch to the off position.
⊙
Result: No machine functions should
operate.