OPERATOR’S MANUAL
with Maintenance Information
Safety Rules
2
Intended Use
This machine is intended to be used only to lift
personnel, along with their tools and materials
to an aerial work site.
Safety Sign Maintenance
Replace any missing or damaged safety signs.
Keep operator safety in mind at all times. Use
mild soap and water to clean safety signs. Do
not use solvent-based cleaners because they
may damage the safety sign material.
Electrocution Hazard
This machine is not electrically insulated and
will not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power
lines and apparatus in accordance with
applicable governmental regulations and the
following chart.
Allow for platform movement, electrical line
sway or sag and beware of strong or gusty
winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the
ground or in the platform must not touch or
operate the machine until energized power
lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for
welding.
Tip-over Hazard
Occupants, equipment and materials must not
exceed the maximum platform capacity or the
maximum capacity of the platform extension.
Indoor/outdoor switch must turn to the outdoor
position while using machine outdoor .if not
the wind forces may make it unstable.
Maximum capacity JCPT03
Maximum capacity JCPT04
Maximum occupants
(Indoor use)
1
Platform allowable maximum load
240 kg
Extension deck allowable maximum load 100kg
Maximum occupants
(outdoor use)
1
Voltage
Phase to Phase
Minimum Safe
Approach Distance
Platform Height ≤2.5m
Platform allowable maximum load
240 kg
Extension deck allowable maximum load 100kg
Work Area Safety
Do not raise the platform unless the machine
is on a firm, level surface.
Do not drive over 0.5 km/h with the platform
raised.
Meters
0 to 300V
Avoid Contact
300V to 50KV
3.05
50KV to 200KV
4.60
200KV to 350KV
6.10
350KV to 500KV
7.62
500KV to 750KV
10.67
750KV to 1000KV
13.72