Dinex TSBH2 Operating & Maintenance Manual Download Page 5

5. Remove the blower wheel (pay attention to rotation 

direction).

6. Unscrew the screws on the blower unit and remove

the unit.

7. Replace blower unit.

8. Reconnect electrical wiring.

9. Reassemble access panel to the unit.

Di n ex Inte rn at i o n a l , I n c. ( “ Di n ex”) wa rra nts that its DES
Eq u i p m e nt (“Eq u i p m e nt”) shall be free from defe cts in
m ate rials and wo rkmanship for a pe ri od of one (1) ye a r
f rom the date of delive ry to the initial end-user (“End-
Us e r”) (the “Wa rra nty Pe ri od” ) . Di n ex shall be notified of all
Eq u i p m e nt claimed to be defe ct i ve and cove red by this
wa rra nty. The End-User shall include in this notification the
s e rial number and a co py of the Bill of Lading (show i n g
d e l i ve ry date) for the Eq u i p m e nt . If Di n ex’s inve s t i g at i o n
establishes the ex i s te n ce of the alleged defe ct s, then Di n ex
s h a l l , at Di n ex’s choice and ex pe n s e, repair or re p l a ce the
a f fe cted Eq u i p m e nt (provided that the costs of labor on
such repairs shall only be included for pro per wa rra nty
claims asserted in writing within 1 year of delive ry date )
and reimburse End-User for the reasonable shipping co s t s
for re t u rning the Eq u i p m e nt to Di n ex , if any.

This warranty does not apply to defects in any Equipment
caused by: (1) normal wear and tear; (2) failure to comply
with any Dinex-provided operation or maintenance
instructions; (3) alteration or modification(s) by parties
other than Dinex or (4) misuse, neglect, accident, Acts of
God or other causes beyond the control of Dinex after
delivery of the Equipment by Dinex to its authorized
distributor.

Repaired or replacement Equipment under this warranty
shall be warranted for the unexpired portion of the origi-
nal Warranty Period applicable thereto plus the period
from notice to Dinex of such defect until completion of
repair or return to the point of original delivery to Buyer.

THIS WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, WHETHER ARISING BY LAW, CUSTOM,
CONDUCT OR USAGE OF TRADE, AND THE RIGHTS AND
REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND
PROVIDED IN LIEU OF ANY OTHER RIGHTS AND
REMEDIES. DINEX SHALL HAVE NO LIABILITY OTHER
THAN AS PROVIDED IN THIS WARRANTY, WHETHER
CLAIMED IN CONTRACT, EQUITY, TORT OR OTHERWISE,
FOR OR RESULTING FROM DEFECTS IN MATERIALS OR
WORKMANSHIP OR OTHERWISE.

IN NO EVENT SHALL DINEX BE LIABLE FOR ANY
SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH
THE EQUIPMENT, REGARDLESS WHETHER SUCH
LIABILITY SHALL BE CLAIMED IN CONTRACT, TORT,
EQUITY OR OTHERWISE.

Page 5

DINEX    Warranty

®

INFO:

Defective parts must be replaced according to

the spare parts list.

THERMOSTAT REPLACEMENT

WARNING:

Turn the master switch to the “0” position and

remove plug from receptacle.

1. Remove the four screws on the access panel and remove

the panel.

2. The Hi-limit thermostat is located in the lower central

area. Remove the wires and screws, then replace the 
Hi-limit thermostat.

3. The thermostat is located on the left-hand side, just

below the blower motor. Remove the wires and screws.

4. Remove the eight screws on the heater unit and remove

the unit.

5. Remove the capillary tube sensors and replace the 

thermostat.

6. Remount the access plate.

HEATER REPLACEMENT 

WARNING:

Turn the master switch to the “0” position and

remove plug from receptacle. To avoid burns allow the unit
to cool down.

1. Remove the four screws on the access panel and remove

the panel.

2. Remove the wires of the master switch, the air exhaust 

fan and the Hi-limit control.

3. Unscrew the eight screws on the heater and remove the 

heater.

4 . Un s c rew the four nuts on the heating unit of the heating 

d ev i ce and re m ove the ve nt i l ation panel.

5. The heating spiral can now easily be removed by

unscrewing the screws and nuts.

IMPORTANT:

Make sure not to bend the motor shaft or

the blades of the blower wheel while mounting the new
heating element.

BLOWER REPLACEMENT 

1. Un s c rew the four scre ws on the access panel and re m ove

the panel.

2. Detach electrical wiring.

3. Unscrew the eight screws on the heater unit.

4. Un s c rew the four nuts on the heating unit of the heating 

d ev i ce and re m ove the ve nt i l ation panel.

!

!

!

!

Replacement Parts

Summary of Contents for TSBH2

Page 1: ...Operating Instructions 2 Maintenance 4 Troubleshooting 4 Replacement Parts 5 Dinex Warranty 5 Parts Diagram 6 Electrical Diagram 7 Model TSBH2 For Service Information call 1 888 673 4639 Please provi...

Page 2: ...uipment should be performed by persons qualified or licensed to install electrical Equipment only It is the responsibility of the installer to comply with all local codes 1 Carefully remove any packin...

Page 3: ...fingers or hand injuries make sure the level of the upper base is 2 5cm higher than the upper edge of the housing See Level Adjustment No 2 for Spring Adjustment 2 Check to be sure that the guide bas...

Page 4: ...r of the dispenser should be cleaned as required at least once every three months 2 Open silo lid and unload dishes CAUTION Bases may be hot Use thermal protection gloves for removal 3 A damp cloth ma...

Page 5: ...OF TRADE AND THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND PROVIDED IN LIEU OF ANY OTHER RIGHTS AND REMEDIES DINEX SHALL HAVE NO LIABILITY OTHER THAN AS PROVIDED IN THIS WARRANTY WHETHER...

Page 6: ...dule 2 014121403 2 Frame Supporting 3 014118208 2 Guide Basket 4 014004105 24 Spring 5 Gram 5 014004106 8 Spring 10 Gram 6 4142275 1 Handle Push 7 014000129 2 Caster 5 With Brake 8 014000128 2 Caster...

Page 7: ...nce Number Part Number Description 1 014001054 Plug 20 Amp 240 Volt 2 014001501 Cord 8 14 3 AWG 3 019014970 Switch Main ON OFF 4 014001209 Thermostat 68 338 F 5 014001211 Thermostat Limit 6 014001110...

Page 8: ...DINEX INTERNATIONAL INC 628 2 HEBRON AVENUE GLASTONBURY CT 06033 1 800 523 9752 WWW DINEX COM Page 8...

Reviews: