Dinex DuraTherm 2011208 Operating & Maintenance Manual Download Page 7

DuraTherm

7

  ERROR CONDITIONS

Error Codes will be indicated by a message 
on the LCD Info Center. If there is more 
than one error condition, the display will 
alternate between the error messages. It will 
continuously repeat this cycle until the errors 
are reset. Error messages may be reset by 
pressing SELECT.

If the error persists, turn the charger off, unplug 
the power cord, wait 5 seconds, and plug it in 
again. If the error still persists, turn the charger 
off and call the Dinex

®

 Service Department at 

1-888-673-4639.

Message: 

 Error! RFID Communications 
problem. Possible bad base. 1/2

Condition:  RFID read/write problem.
Check: 

 Possible bad electronics chip on 
the base, or RF antenna/reader 
problems. If isolated to one or 
more bases, set them aside and 
call service about those bases. If 
error issued with many bases, call 
service about the charger.

Message: 

Error! Incompatible base. 3

Condition:  Base draws too much current.
Check: 

 Object being heated is not a 
Dinex

®

 base or internal charger 

problem. 

Message: 

 Error! Unit overheat! Check fan 
operation. Allow to cool. 4

Condition:  Internal unit temperature too hot.
Check: 

 Fan stalled, restricted air flow, or 
ambient operating temperature too 
hot. Possible internal electronics 
fault. Verify grease filters are not 
blocked and unrestricted airflow 
about the bottom of the unit. Listen 
for fan operation. If error persists, 
call Dinex

®

 service.

Message: 

Error! Incoming voltage too high. 6

Condition:   Line voltage measures greater 

than 110% of unit rated voltage.

Check: 

 Line voltage spikes, possible 
voltage sensing electronics 
fault. Have maintenance verify 
line voltage. Recalibrate to 
your line conditions (for trained 
maintenance personnel only):

1.   Measure voltage across two phases of 

power with a voltmeter (typically about 
208V)

2.   Set unit to OFF position – with DINEX in the 

display.

3.   Press and hold the DOWN arrow for 7 

seconds.

4.   Release, and within 2 seconds, press 

POWER once. The CALIBRATION screen 
should display.

5.   Using arrow keys, move caret to Set V 

Offset. Press SELECT.

6.   Using UP/DOWN arrow keys, dial in the 

measured phase voltage. Press SELECT.

7.   Please do not use the reset logs selections, 

this will clear valuable stored information 
should your unit require additional service.

8.  Select EXIT or cycle the POWER button.

Message: 

 Critical Error! Unit requires service. 
Call Dinex (888) 673-4639. 7

Condition:   Inverter drawing power when 

commanded off.

Check: 

 Possible internal electronics fault. 
Unplug, wait 5 seconds, and 
replug unit. If error persists, call 
Dinex

®

 service.

Message: 

 Error! Check incoming voltage! 
If problem persists, Call Dinex 
Service (888) 673-4639. 8

Condition:   Poor power quality.
Check: 

 Major line voltage sags (severe 
brown out) or internal electronics 
fault. Have maintenance verify line 

Summary of Contents for DuraTherm 2011208

Page 1: ...el number Serial number from bottom of unit Table of Contents Introduction 2 Freight Damage Claims 2 Applications and Use 2 Safety 2 Installation 3 Operation Instructions 4 User Interface 4 Manager Op...

Page 2: ...en 15 days after delivery was made Be sure to retain all packing materials and cartons ATTENTION Use of this symbol identifies a potentially hazardous situation which if not avoided may result in dama...

Page 3: ...nit specifies the operating voltage current frequency phase and maximum wattage of the charger Plugging or wiring the charger into less voltage than the charger is rated may significantly decrease the...

Page 4: ...y should not be connected to circuits sharing compressors or other heavy current draw devices i e plate heaters steam tables etc 3 Do not move the DuraTherm Charger when it is electrically connected 4...

Page 5: ...completely filled the charger will display Base Ready and will beep indicating that base is at full charge A DuraTherm base will usually charge completely in 15 seconds A SmartTherm base will usually...

Page 6: ...Safety relevant parts should be replaced with original factory parts only Any defective parts must be removed and replaced by a qualified service technician authorized by Dinex Should you require serv...

Page 7: ...restricted airflow about the bottom of the unit Listen for fan operation If error persists call Dinex service Message Error Incoming voltage too high 6 Condition Line voltage measures greater than 110...

Page 8: ...ired it Check Set base aside for reuse after one or two hours MAINTENANCE DURATHERM CHARGER CLEANING INSTRUCTIONS 1 Unplug the charger before cleaning Do not submerge the charger in water Do not splas...

Page 9: ...inex warrants that the Warranted Products will be free from defects in title material and workmanship under normal use and service and will perform substantially in accordance with Dinex s written tec...

Page 10: ...OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL EXPRESSED IMPLIED OR STATUTORY EXCEPT AS PROVIDED HEREIN NO EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILIT...

Page 11: ...that may be delivered with the Warranted Product In addition these warranties do not cover i Any defect or deficiency including failure to conform to Product Specifications that results in whole or in...

Page 12: ...DuraTherm 12 12...

Page 13: ...DuraTherm 2016 Carlisle FoodService Products Oklahoma City OK 73131 www carlislefsp com 800 654 8210...

Reviews: