4.   The “Set Language”, “Ignore Warnings”, 

and “Set LCD Contrast” options will bring 
up sub-menus where you may select the 
desired mode. “Set Languages” allows 
you to choose between displaying English, 
Spanish, or French. “Ignore Warnings” 
allows you to suppress the display of 
certain informational warning messages 
(for example, you may suppress the display 
of “Low Voltage” warnings during times of 
heavy electrical demand where voltage on 
power lines may sag).

5.   Choose “Exit” to back out of the displayed 

menu.

6.   At any time, you may also press the POWER 

key to cycle the unit back into normal 
operation.

 INFORMATIONAL 

 WARNING

An informational warning messages may 
appear in the course of operation. Make note 
of and correct the condition as soon as is 
practical. Press the SELECT key to continue 
normal operation.

1.  

Warning!

 Low voltage condition exists. 

Performance may suffer. Press SELECT to 
continue. 

 

 This indicates that the unit senses the line 
voltage has dropped where charge times 
may be adversely affected. The unit will 
pause operation until SELECT is pressed. 
No harm will result if you continue to 
operate the unit. If these warnings become 
excessive (for example, during periods 
of high electrical demand), they may be 
suppressed from the OPTIONS menu.

 TROUBLESHOOTING

!     IMPORTANT:

 Safety-relevant parts should be 

replaced with original factory parts only. Any 
defective parts must  be removed and replaced 
by a qualified service technician authorized by 
Dinex

®

. Should you require service please call 

the Dinex

®

 Hotline at 1-888-673-4639. In order 

for the warranty to remain valid, work must be 
authorized by Dinex

®

 prior to being performed.

The Dinex

®

 DuraTherm

 Charger is a very 

intelligent device. Built in diagnostics can 
help you to determine the cause of most 
problems. The following section explains how 
to determine if you are experiencing a problem 
and what can be done to correct the problem. 
This information can be very helpful if you are 
calling our Customer Service department to 
report any operational difficulties.

1.   Errors are displayed in easy to understand 

text on the LCD Screen.

2.   If an error occurs, press SELECT to clear 

the error and try again. Or remove the base 
from the charger and turn the charger OFF 
and back ON again.

3.   If an error persists, remove the base from 

the charger, turn the power off and unplug 
the charger, wait 5 seconds and then plug 
the charger back in and turn the charger on 
by pressing the “POWER” button.

4.   When the display reads “Waiting For 

Base”, put the base back on the charger to 
continue charging. Make sure that the base 
is properly positioned on the charger.

5.   If the base still doesn’t heat, set it aside and 

take it out of service. If other bases exhibit 
similar conditions note the error code and 
call Dinex

®

 Service.

Summary of Contents for DuraTherm 2011208

Page 1: ...el number Serial number from bottom of unit Table of Contents Introduction 2 Freight Damage Claims 2 Applications and Use 2 Safety 2 Installation 3 Operation Instructions 4 User Interface 4 Manager Op...

Page 2: ...en 15 days after delivery was made Be sure to retain all packing materials and cartons ATTENTION Use of this symbol identifies a potentially hazardous situation which if not avoided may result in dama...

Page 3: ...nit specifies the operating voltage current frequency phase and maximum wattage of the charger Plugging or wiring the charger into less voltage than the charger is rated may significantly decrease the...

Page 4: ...y should not be connected to circuits sharing compressors or other heavy current draw devices i e plate heaters steam tables etc 3 Do not move the DuraTherm Charger when it is electrically connected 4...

Page 5: ...completely filled the charger will display Base Ready and will beep indicating that base is at full charge A DuraTherm base will usually charge completely in 15 seconds A SmartTherm base will usually...

Page 6: ...Safety relevant parts should be replaced with original factory parts only Any defective parts must be removed and replaced by a qualified service technician authorized by Dinex Should you require serv...

Page 7: ...restricted airflow about the bottom of the unit Listen for fan operation If error persists call Dinex service Message Error Incoming voltage too high 6 Condition Line voltage measures greater than 110...

Page 8: ...ired it Check Set base aside for reuse after one or two hours MAINTENANCE DURATHERM CHARGER CLEANING INSTRUCTIONS 1 Unplug the charger before cleaning Do not submerge the charger in water Do not splas...

Page 9: ...inex warrants that the Warranted Products will be free from defects in title material and workmanship under normal use and service and will perform substantially in accordance with Dinex s written tec...

Page 10: ...OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL EXPRESSED IMPLIED OR STATUTORY EXCEPT AS PROVIDED HEREIN NO EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILIT...

Page 11: ...that may be delivered with the Warranted Product In addition these warranties do not cover i Any defect or deficiency including failure to conform to Product Specifications that results in whole or in...

Page 12: ...DuraTherm 12 12...

Page 13: ...DuraTherm 2016 Carlisle FoodService Products Oklahoma City OK 73131 www carlislefsp com 800 654 8210...

Reviews: