FLD-32
©
Dinel, s.r.o.
6
FASTENING USING SELF-ADHESIVE LAYER
This technique may be used for flat or slightly curved surfaces with a diameter larger than 300 mm.
1.
One protective film is removed from the adhesive layer and attached to the bottom of
the sensor.
2. The target area should be cleaned and degreased.
3.
Remove the second protective film and apply slight pressure to the sensor to attach it to
the desired location.
When replacing or removing the sensor, the sensor should be detached from the wall of the
tank carefully. If the original self-adhesive layer is destroyed, it needs to be removed from the
sensor and a new one should be used (delivered as accessories).
32
48
min. ø 300
sensor
tank wall
self-adhesive layer
cable
Fastening the FLD-32 using self-adhesive layer
fastening bands
with ø 180 - 300 mm
FASTENING USING ATTACHMENT BANDS
This technique is recommended for curved surfaces with a diameter of 180 - 300 mm. Use two
bands for fastening (each has one end modified).
1.
The modified end of the band is threaded from the inside through the fastening eyelet
and glued over.
2. The same technique is used to attach the band at the second fastening eyelet.
3.
The sensor is placed at the desired location on the tank, wrapping the bands around the
tank, tightening them and gluing over.
The sensor must be fastened well otherwise the function of the sensor may be unstable.
Fastening FLD-32 using attachment bands