background image

Copy and Paste Time profiles

It is possible to copy the complete time profile from one day and paste it to another 

day. This will copy all four program periods and associated time and temperatures. To 

copy and paste a day profile:

•  From the day selection screen, use the arrow keys to highlight the day you wish 

to copy.

• Hold the 

ADV

 key for 2 seconds, ‘COPY’ will flash on screen to show it has copied,

• Use the arrow key to highlight the day to which you wish to copy the profile.

•   Hold  the 

ENTER

 key for 2 seconds, ‘PSTE’ will flash on the screen and the appliance 

will beep to signify the timers have been pasted successfully.

•  If required the same profile can then be copied to other days using the same ‘Paste’ 

procedure.

1.

   Hold 

ADV

 for 2 seconds on 

Monday (1)

2.

   Press 

UP

 until Thursday 

(4) is flashing

3.

   Hold 

ENTER

 to paste timers 

onto selected day

Flashing icon
Double Flash

22

Summary of Contents for WFE3BE

Page 1: ...08 53943 0 ISSUE 1 WFE Wall Fan Convector Model WFE3BE WFE3SE INSTRUCTION MANUAL Installation and Operating This product is supplied and operated with a Bluetooth Remote Control handset ...

Page 2: ... heater carries a warning Do Not Cover to alert the user to the risk of overheating that exists if the heater is accidentally covered Keep combustible materials such as drapes and other furnishings clear from the front of the heater Do not use heater to dry your laundry NEVER cover or obstruct in any way the air inlet slots at the front of the heater or the heat outlet slots in the base of the hea...

Page 3: ...ent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility DO NOT use where excessive dust or moisture is present For further information please contact our guard supplier direct on Tel No 01603 667957 or in the case of difficulty or for further advice c...

Page 4: ...electricity Consumption At nominal heat output elmax 0 00 0 00 At minimum heat output elmin 0 00 0 00 In standby mode elSB 0 0005 0 0005 Type of heat output room temperature control Electronic room temperature control plus week timer Yes With open window detection Yes With adaptive start control Yes This product complies with Lot20 of the Energy Efficiency Directive 2015 1188 Energy Related Produc...

Page 5: ... with integral thermal cut out Installation Fixed directly to the wall through the back panel Safety Eelectrical reset self hold cut out IP Rating No Rating Battery Backup None However all programmed timer profiles will be retained during short term power losses In order to ensure their correct operation it is necessary to restore the time and date settings this happens automatically once paired w...

Page 6: ...be provided adjacent to the final position of the appliance In this instance such a termination can be a double pole switch with a contact separation of at least 3mm in all poles The heater must not be located immediately below a fixed socket outlet Procedure Release the front cover from the unit by undoing the two screws under the bottom edge Carefully remove the cover by pulling bottom front for...

Page 7: ...Fig 1 Fig 2 shelf 571mm 510mm 150mm min 6mm 8mm 10mm 350mm 280 mm A 350mm 35mm 571 mm 120 mm 350 mm 350mm MIN 7 ...

Page 8: ...dard 13A socket If the latter Connect Green and Yellow wire to plug terminal marked E or Green or Green and Yellow Connect Blue wire to plug terminal marked N or Black Connect Brown wire to plug terminal marked L or Red Refit cover first hooking top over the back of the unit and then securing the bottom by refitting the two screws under the bottom edge The appliance is now ready for use and the el...

Page 9: ...9 ...

Page 10: ...te the appliance When paired with the remote control various operational modes and features can be accessed IMPORTANT NOTE The remote control is required to operate the appliance It is important that the remote control remains near the appliance at all times Remote Control 1 Display Screen 2 Menu Button 3 Back Button 4 Advance Button 5 Up and Down Arrows 6 Enter Button 1 3 6 2 4 5 10 ...

Page 11: ...ave been successfully fitted the remote control will immediately start scanning for a product to control At this stage it is necessary to complete the pairing process see Remote Pairing Instructions Remote control cradle The remote control is supplied with a wall mounting cradle If desired mount the cradle in a suitable location The cradle can be mounted using suitable screws and the appropriate w...

Page 12: ...lease ensure that no other products are broadcasting within the vicinity to prevent pairing to the incorrect product 3 The remote will search for devices for 1 minute If no product can be found the remote will display NO PROD before returning to a sleep state If this happens please repeat steps 1 and 2 4 If connection is successful the product will emit a second beep and the remote screen will sho...

Page 13: ...e remote will automatically move to the date setting 1 After confirming the last time digit Day will blink three times and then change to a two digit number with the first digit blinking This two digit number represents the day of the month 2 Use the arrow key to set the first digit of the date and confirm using the ENTER button 3 The second digit will then blink and can be set as per step 2 4 Aft...

Page 14: ...14 ...

Page 15: ...4 5 Arrow keys used to navigate through the menus and adjust the room temperature set point 6 ADV use depends on the active mode and settings typically used to advance the program in timer mode or to initiate a runback period in Manual PIN mode Advanced button functions Shortcut keys Comfort Off Press and hold for 2 seconds Temp Settings Press and hold for 2 seconds Heating Settings Press and hold...

Page 16: ...here are also a number of advanced control options and features available Runback Mode This is an additional feature available to manual mode with this mode active the manual mode will operate for a determined time period and then revert to Comfort Off mode Setback Mode This is an additional feature available to timer mode with this mode active the appliance will control the room to a pre set temp...

Page 17: ...erwise OFF will be displayed Active mode display the active mode of operation is displayed at the bottom of the screen Sleep mode when the remote is left inactive the remote display will sleep turning the screen off Briefly hold ENTER to wake the remote back up The remote control will enter sleep mode if left idol for the following intervals Home Screen Sleep after 10 seconds Menu Screens Sleep af...

Page 18: ...sired icon and confirm selection using the ENTER key Depending on the mode selected you may be prompted for further action see relevant section relating to this mode The heater is fitted with an adjustable electronic thermostat enabling the room temperature to be controlled in all the operational modes The minimum controllable room temperature available is 7 C and the maximum temperature is 30 C A...

Page 19: ...d hold the ADV button for 2 seconds The remote will enter the heat selection screen Use the arrow keys to navigate to the desired setting and confirm using the ENTER key The remote will return to the home screen and all heating modes will function with the selected heat output NOTE The HI temperature setting will modulate the heat output to optimise the efficiency of the product As the room temper...

Page 20: ...ey from the home screen Use the arrow keys to highlight the Schedule Icon Press ENTER to enter Timer Settings Ensure On is highlighted and Press ENTER again to activate timer mode The active settings and target set temperature will be displayed on the home screen Timer Mode NOTE If Adaptive Start is enabled the heater may operate outside the programmed heating period This is normal and is required...

Page 21: ... is confirmed the remote will automatically enter the set point setting screen Use the arrow keys to set the desired set point temperature confirm using the ENTER key The Off time should then be set using the same method as the On period You will then be returned to the Period setting screen with the next period highlighted The previous Period has been successfully set and is confirmed by a beep f...

Page 22: ...ey for 2 seconds COPY will flash on screen to show it has copied Use the arrow key to highlight the day to which you wish to copy the profile Hold the ENTER key for 2 seconds PSTE will flash on the screen and the appliance will beep to signify the timers have been pasted successfully If required the same profile can then be copied to other days using the same Paste procedure 1 Hold ADV for 2 secon...

Page 23: ...e within the Heater s Temperature Range Frost Protection Default 7 C Can be changed from the Home Screen to any value however once the temperature is changed the unit will revert to a standard Manual mode Comfort Off Heating OFF no temperature control Activating a Continuous Heat Mode Manual Mode Comfort On This mode ignores the User Timer and maintains the displayed temperature To activate manual...

Page 24: ...int reached 7 C NOTE If the temperature is raised in Frost Protect the product will automatically enter Manual Mode Comfort Off When activated this appliance will provide no room temperature control No active mode will be visible on the screen but the remote will display the current time and day indicating the appliance is in comfort off mode The remote screen will still revert to sleep mode To ac...

Page 25: ...o have the heating on If the remote displays OFF Schedule Icon or no target temperature and heat is required press the ADV button If the remote displays ON and heat is not required press the ADV button and the heater will stop heating until the beginning of the next ON period Pre action State Action Impact Heating On Timer Mode Advance activated Heating On period switched to Heating Off until the ...

Page 26: ... desired the additional runback duration periods can be accessed by pressing the ADV button There will be four runback time durations available to select from Continue pressing Advance until the desired runback time has been reached When satisfied with the selection press ENTER to confirm Once active the set point will change to the pre set value that has been selected during the runback setup The...

Page 27: ...on The advanced menu options are Runback Setback Adaptive Start PIN lock Runback Settings This menu is used to activate the runback function and also setup the main function parameters see Runback in Advanced mode Functions for description of this mode To activate and setup Runback mode Hold down ADV and MENU buttons for 2 seconds rb will be highlighted on the screen Press ENTER to enter the Runba...

Page 28: ... select the desired Runback temperature Press ENTER to activate the Runback timer and return to the home screen Maximum Runback Duration Selectable Runback options Period 1 Period 2 Period 3 Period 4 0 30 0 15 0 20 0 25 0 30 1 00 0 15 0 30 0 45 1 00 1 30 0 15 0 30 1 00 1 30 2 00 default 0 30 1 00 1 30 2 00 4 00 1 00 2 00 3 00 4 00 6 00 1 30 3 00 4 30 6 00 8 00 2 00 4 00 6 00 8 00 NOTE When activat...

Page 29: ...and for heat Heating On To activate and setup setback mode Hold the ADV and MENU buttons for 2 seconds Use the arrow keys to highlight Sb and confirm using the ENTER key Use the arrow keys to select Setback ON or OFF Selecting OFF will return you to the home screen with Setback deactivated If ON icon is selected you will be required to set a Setback temperature Use the arrow keys to select the des...

Page 30: ...r mode home screen NOTE This is a continuously learning function and will be affected daily by changes in the heater s environment The heater will take into account the starting temperature of the room so pre heating should remain accurate NOTE It is important that if multiple heaters are installed in one room that all heaters have the Adaptive Start AS function enabled If this is not the case hea...

Page 31: ...the appliance will continue to control to the pre set comfort on temperature Runback mode is not available Frost protect All functionality will be disabled the appliance will continue to provide frost protection Runback mode is not available Comfort Off All functionality will be disabled the appliance will remain in Comfort off mode with no heat or temperature control Runback mode if active can be...

Page 32: ...first digit Press ENTER to confirm Repeat until all four digits have been entered then press ENTER to confirm If the correct PIN has been entered the device will be unlocked and you will be returned to the home screen If incorrect the word Inc will flash for 1 second Pin will be displayed for 1 second then the screen will return to the PIN locked home screen Screen is displayed for 1 second before...

Page 33: ...croll through the information pages Once all the information screens have been viewed the remote will return to the home screen Alternatively if idol for 5 seconds the screen will return to the home screen You may exit this screen at any time by pressing BACK UI Software version Not assigned Remote Software Version UI ID NAME Service Settings Temperature Settings To choose whether the remote displ...

Page 34: ...the Bluetooth remote Hold down Up and Down buttons at the same time for 5 seconds to enter Fr Factory Reset options Use the arrow keys to toggle factory reset Heater h or Remote r and press ENTER to confirm your option Use the arrow keys to toggle Factory reset YES y or NO n and press ENTER to confirm your option 34 ...

Page 35: ...ct However the time and date settings on the handset will have been lost and must be reset for time profiles to function correctly IMPORTANT Battery should be disposed of in an appropriate manner Cleaning General Cleaning External appearance can be maintained by wiping occasionally with a damp cloth for stain removal a weak soap solution can be applied then wipe dry The filter should be cleaned by...

Page 36: ...sh attachment of a vacuum cleaner Care should be taken not to damage the blades Filter The filter see C Fig 4 can be removed completely for cleaning but generally provided this is cleaned frequently as detailed above this should not be necessary Where removal of filter is required for cleaning the filter retaining wires see A Fig 4 can be removed allowing the mesh see B Fig 4 and the filter to be ...

Page 37: ...seful life it should not be disposed of with household waste Please recycle where facilities exist Check with a Local Authority or retailer for recycling advice in your country Batteries should be disposed of or recycled in accordance with WEEE Directive 2012 19 EU Packaging should be recycled where possible Fig 4 37 ...

Page 38: ...uct its serial number and a description of the fault which has occurred You can find the model number and serial number for your Dimplex product on the heaters side Once we receive your information and proof of purchase we will contact you to make the necessary arrangements If your Dimplex product is not covered by this Dimplex Warranty there may be a charge to repair your product However we will ...

Page 39: ...e original receipt as proof of purchase and if required by Dimplex proof of delivery If you are unable to provide this documentation you will be required to pay for any repair work required Any repair work under the Dimplex Warranty will be carried out by Dimplex or its authorised dealer s and any parts that are replaced will become the property of Dimplex Any repairs performed under the Dimplex W...

Page 40: ... co uk Glen Dimplex Heating and Ventilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF Glen Dimplex All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex ...