Power Output

35°C

45°C

55°C

65°C

35°C

45°C

55°C

65°C

3

1631

2734

3844

4959

3

1480

2502

3520

4546

2

1079

1803

2530

3260

2

1020

1713

2406

3102

1

641

1069

1499

1929

1

625

1044

1464

1885

3

1299

2177

3061

3951

3

1199

2024

2850

3682

2

838

1403

1968

2536

2

802

1346

1892

2439

1

493

823

1154

1484

1

484

808

1133

1459

3

1120

1878

2641

3408

3

1044

1760

2479

3202

2

719

1201

1686

2172

2

691

1160

1629

2100

1

415

693

971

1249

1

408

683

957

1231

3

759

1273

1790

2050

3

719

1210

1705

2203

2

479

801

1124

1448

2

465

780

1095

1412

1

251

419

588

756

1

249

416

582

749

35°C

45°C

55°C

65°C

35°C

45°C

55°C

65°C

3

1059

1832

2648

3498

3

852

1431

2020

2559

2

820

1408

2021

2655

2

695

1167

1647

2109

1

558

948

1346

1750

1

506

848

1175

1542

3

900

1558

2256

2984

3

752

1269

1798

2263

2

671

1151

1651

2167

2

591

995

1355

1793

1

442

749

1063

1378

1

411

691

955

1251

3

806

1394

2016

2668

3

689

1164

1557

2070

2

591

1010

1447

1894

2

530

894

1215

1606

1

379

641

907

1174

1

357

599

828

1083

3

587

1012

1460

1926

3

530

902

1190

1580

2

413

704

1005

1309

2

387

655

884

1163

1

237

399

564

728

1

231

387

534

694

35°C

45°C

55°C

65°C

35/30°C

45/40°C

55/47°C

65/50°C

3

551

918

1284

1649

3

1495

2856

3925

4628

2

487

812

1136

1460

2

893

1760

2424

2879

1

394

657

920

1183

1

522

1008

1395

1636

3

511

852

1193

1535

3

1078

2172

2982

3492

SRX120

SRX120

SRX180

SRX180

SRX140

SRX140

SRX80

SRX80

SRX180

SRX180

SRX140

SRX140

SRX120

SRX120

SRX80

SRX80

SRX180

SRX180

Q =  450 l/h

Q =  300 l/h

Q =  150 l/h

Q =  100 l/h

2

436

728

1020

1313

2

631

1329

1828

2154

1

338

564

791

1019

1

344

752

1039

1176

3

480

802

1124

1446

3

870

1826

2506

2924

2

402

672

943

1215

2

561

1119

1541

1770

1

302

504

707

912

1

331

621

856

1017

3

392

655

921

1191

3

573

1165

1595

1777

2

312

522

734

950

2

358

695

956

1137

1

207

345

486

627

1

201

375

516

607

Q

SRX120

SRX80

SRX80

SRX140

SRX140

Q =  50 l/h

SRX120

7

Summary of Contents for SRX 080M

Page 1: ...The product complies with the European Safety Standards EN60335 1 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC DE EN srx_en de_ba 12 10 A ...

Page 2: ... 30 125 MIN 590 MIN 535 150 MIN 150 MIN 235 MIN 100 MIN a d b c J A E B F C G D H K 1 2 3 4 82 A B C D SRX 080 503 324 396 386 SRX 120 670 492 564 564 SRX 140 740 562 634 624 SRX 180 911 732 804 794 50 15 150 50 220 ...

Page 3: ...P N L1 P N L1 5 6 ...

Page 4: ... 1063 1378 1 411 691 955 1251 3 806 1394 2016 2668 3 689 1164 1557 2070 2 591 1010 1447 1894 2 530 894 1215 1606 1 379 641 907 1174 1 357 599 828 1083 3 587 1012 1460 1926 3 530 902 1190 1580 2 413 704 1005 1309 2 387 655 884 1163 1 237 399 564 728 1 231 387 534 694 35 C 45 C 55 C 65 C 35 30 C 45 40 C 55 47 C 65 50 C 3 551 918 1284 1649 3 1495 2856 3925 4628 2 487 812 1136 1460 2 893 1760 2424 287...

Page 5: ...Casing cover b Control panel c Air outlet guard d 1 m connection cable Fan convectors may only be used in central heating systems with a closed control circuit The heating system must be operated as a dual pipe system The devices must be of a sufficient rating such that they can compensate for heat losses in the room Technical data SRX 80 SRX 120 SRX 140 SRX 180 Heat output kW at flow temperature ...

Page 6: ...e forwarded to any downstream devices via the control conductor see fig 6 on the right The control conductor does not have to be in phase with the supply connection If the control conductor is not used it must be properly insulated WARNING if you switch over to controlled operation the mains voltage is on this conductor WARNING do not ground the control conductor When taking out of service e g for...

Page 7: ...w temperature higher on heating system Insufficient water flow rate through device Adjust flow rate hydraulic balance To do this close ther mostat valves on the other heaters Dirt on heat exchanger Clean heat exchanger see Maintenance section Cleaning outer surfaces The heater must be switched off and cooled for cleaning The surfaces of the heater can be cleaned by wiping with a soft damp cloth an...

Page 8: ...erden Das Gerät saugt auf der Unterseite Luft an Diese wird im Wärmetauscher erwärmt und nach oben ausgeblasen Abb 1 a Gehäuseabdeckung b Bedienfeld c Luftaustrittsgitter d Anschlussleitung 1 m Die Gebläsekonvektoren dürfen nur in Zentralheizungsanlagen mit geschlossenem Regelkreis verwendet werden Die Heizungsanlage muss als Zweirohrsystem ausgeführt sein Die Geräte müssen ausreichend dimensionie...

Page 9: ...tete Geräte weitergegeben Betrieb mit Programmierkassette Die Steuersignale der im Pilotgerät eingesteckten Programmier kassette werden über den Steuerleiter an eventuell nachge schaltete Geräte weitergegeben siehe Abb 6 rechts Der Steuerleiter muss nicht phasengleich zum Netzanschluss sein Wird der Steuerleiter nicht verwendet muss dieser fachge recht isoliert werden ACHTUNG beim Umschalten auf g...

Page 10: ...reichender Wasserdurchfluss durch das Gerät Durchflussmenge einstellen hydraulischer Abgleich Hier für die Thermostatventile an den weiteren Heizkörpern zu drehen Schmutzablagerungen am Wärmetauscher Wärmetauscher reinigen siehe Abschnitt Wartung Außenflächen reinigen Zur Reinigung muss das Heizgerät ausgeschaltet und abgekühlt sein Die Oberflächen des Heizgerätes können durch Abwischen mit einem ...