Function

Compared with traditional storage heaters the amount 

of energy released from the outer case of the heater 

is signifi cantly reduced, resulting in lower surface 

temperatures. This allows more effi cient running 

because the Quantum is heating the room only when 

you want it to.

The stored energy is primarily released by using a low 

speed fan to ‘push’ the heat from the stored core and 

into the room. Running the timed programs or adjusting 

the temperature thermostat will prompt the heater to run 

the fan automatically if it is required. 

N

OTE

D

UE

 

TO

 

THE

 

LOW

 

ENERGY

 

LOSSES

 

FROM

 

THE

 

CASING

 

OF

 

THE

 

HEATER

 

THE

 

SURFACE

 

TEMPERATURE

 

MAY

 

APPEAR

 

TO

 

BE

 

LOW

BUT

 

THIS

 

IS

 

NORMAL

.

N

OTE

O

CCASIONAL

 

CLICKING

 

SOUNDS

 

DURING

 

OPERATION

 

ARE

 

DUE

 

TO

 

TEMPERATURE

 

CHANGES

 

IN

 

THE

 

STORAGE

 

CORE

.

Summary of Contents for QM070 QM100 QM125 QM150

Page 1: ...ntum Heater Models QM070 QM100 QM125 QM150 Boost Output 230 240V 567 630W 792 880W 1017 1130W 1242 1380W Storage Element Rating 230 240V 1435 1560W 2042 2220W 2540 2760W 3024 3300W Rated Charge Period...

Page 2: ...ly switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the applian...

Page 3: ...2 of the front of the heater and 75mm 3 of each side Curtains must not come to within 75mm 3 of the top of the heater DO NOT SIT OR STAND ON THE HEATER DO NOT PLACE OBJECTS IN CONTACT WITH THE HEATER...

Page 4: ...d heat from the outer casing means that more energy is available when warmth is required This makes more ef cient use of the stored energy as you can turn off the heater when you are out or do not nee...

Page 5: ...e stored energy is primarily released by using a low speed fan to push the heat from the stored core and into the room Running the timed programs or adjusting the temperature thermostat will prompt th...

Page 6: ...button 4 Advance button 5 Selector Dial 1 2 3 4 5 The minimum room temperature setting is 16 C The maximum temperature setting available is 26 C A temperature of approximately 20 C represents a normal...

Page 7: ...and activates the fan which will remain ON until the next OFF period is due or OFF until the next ON period is due By repeatedly pressing ADVANCE enables the boost element to maintain the temperature...

Page 8: ...ay after a period of 20 seconds of inactivity Press the Menu button 1 Select Date Time by pressing the Selector Dial 2 Rotate Selector Dial to select the correct day and press centre of dial to select...

Page 9: ...y which can be altered if desired 06 00 until 08 30 17 00 until 22 00 2 Home All Day pre programmed has the following preset times Monday to Sunday which can be altered if desired 06 30 until 09 30 11...

Page 10: ...o update it Once the rst day has been set up it is possible to copy these settings to successive days or all days by again choosing Modify selecting the day with the correct settings and either choosi...

Page 11: ...supplemental heating boost element controlled by the electronic thermostat is provided in case additional room heating is required This will operate only by selecting Advance and then selecting Boost...

Page 12: ...mation menu three choices are available SP Range enables adjustment of the set temperature range available Minimum temperature can be adjusted down to 7 C and maximum temperature adjusted up to 30 C F...

Page 13: ...appearance of the heater it need only be wiped over occasionally with a dry duster During the summer months or at other times when the appliance is not in use and is completely cold the opportunity s...

Page 14: ...14...

Page 15: ...15...

Page 16: ...ory service ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY Your product is guaranteed for two years from the date of purchase Within this period we undertake to repair this product free of charge...

Reviews: