background image

 

OPErATION

2

www.dimplex.com

Proceed to the wiring instructions.

6. 

supply Wiring and Heater Installation

  

WArNINg: 

Wiring procedures and connections should 

be in accordance with the National Electric Code (NEC & 

CEC) and local codes.

Insert approximately 6” (15.2 cm) of supply wire into 

1. 

recess box through the desired knockout. Wire should be 

rated for a minimum of 75°C (167°F)
Connect power supply to terminals provided marked L1 

2. 

and L2. Ground wire should be secured to green wire 

provided inside of the heater assembly. 

  

WArNINg: 

All units are factory prewired for operation 

with the built-in thermostat. 

THIS HEATER IS nOT TO BE 

USED WITH A REGULAR WALL THERMOSTAT

.

Do a final and complete check of all wiring.

3. 

Attach heater by hanging heater on upper tabs then se

-

4. 

curing at the bottom using the supplied screw.

Insert the air filter through the bottom slot, until it clicks 

5. 

into place.

  

WArNINg: 

TO PREVEnT THE RISk OF FIRE OR 

InjURy, DO nOT OPERATE THE HEATER UnLESS IT 

IS FULLy ASSEMBLED.

Figure 2

Securing Tabs

Retaining Screw

Washable Filter

  

WArNINg: 

This heater is factory prewired for operation 

with the built-in thermostat. 

THIS HEATER IS nOT TO BE 

USED WITH A REGULAR WALL THERMOSTAT

.

 CAUTION: 

This heater must be properly installed before 

it is used.

!

 NOTE: 

Prior to energizing remove all construction dirt 

(plaster, sawdust, etc.) from interior and exterior of heater.
The PCH is a Precision Comfort Heater, which maintains a 

constant room temperature through the continuous addition 

of heat by the blowing of air into the room based on the 

setting of the thermostat. The PCH operates such that once 

the room reaches the set point, the fan and heater 

will 

continuously run 

at a low level, to maintain the desired 

room temperature. If the temperature in the room rises, 

i.e. sun coming through a window, the fan will slow further 

and the temperature of the heater will reduce so that the 

temperature of the room will continue to be the same. 

!

 NOTE: 

The element retains heat after shutdown, there 

is a built in cool down period of 2 ½ minutes before the fan 

shuts off completely.

  

WArNINg:

 Should the Over Temp light come on, discon

-

nect power to the heater and call a licensed electrician. 

DO nOT USE HEATER UnTIL THE CAUSE OF THE 

PROBLEM IS DETERMInED AnD FIXED. 

Dimplex heaters are designed and tested for safe and 

trouble-free operation. All Dimplex heaters are protected 

against overheating by a built-in thermal cutout. Free airflow 

throughout the heater is extremely important for the most 

efficient operation of the heater. Restricted airflow may cause 

the thermal overload protector to cycle the heater “On and 

OFF”. A cycling heater will not supply sufficient heat to the 

room.

!

 NOTE: 

The unit is designed so that the fan and heater 

will run continuously. During normal operation the fan should 

be running at a low speed to maintain the room temperature.

manual Controls

(See Figure 3 for display reference)
When power is first supplied to the PCH the Setpoint 

Temperature will flash in the temperature display area. At any 

time either the 

 or 

 

button can be pressed to have the 

temperature setpoint displayed again.

A. setting/Temperature Display 

 

The PCH is designed to control the temperature of a room 

anywhere from 32-86°F (0-30°C).  By pressing the 

 or 

 

will increase or decrease the desired temperature for the 

room to be heated by 0.5° (in either °C or °F).
After 5 seconds the Setpoint Temperature will switch to 

display the ambient temperature of the room.

!

 NOTE: 

Pressing the

 

 and 

 at the same time will toggle 

between °C and °F.

B. Comfort setting

 

The Comfort Setting icon will be displayed when the heater 

is in normal operation based on the Setpoint Temperature for 

the room.

!

 NOTE:

 Either the   or 

 icon will always be visible, 

dependent on the setting being used.

M

L1

L2

R

G

Cutout

Over 

Temperature 

Light

Control 

Board

Display 

Board

Motor

Heater

Temperature 

Sensor

Wiring

Reviews: