In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.
© 2014 Dimplex North America Limited
1367 Industrial Road Cambridge ON Canada N1R 7G8
1-888-346-7539 www.dimplex.com
Warranty
The Manufacturer warrants the linear convector and
components of the enclosed product against any defect
in material or workmanship for a period of two years from
the date of purchase, with the exception of the elements
which are warranted to be free from defect in material and
workmanship for five years. In full satisfaction of any claims
under this Warranty the Manufacturer will repair or replace
without charge, in its factory or in the field as it alone may
decide, any parts which in its opinion are defective.
The Manufacturer shall not be responsible for any
transportation or shipping costs in relation to such repair
or replacement except as specifically assumed by it.
Misuse of this product or repairs by persons other than
the Manufacturer’s authorized personnel without the
Manufacturer’s written approval, will void this Warranty.
This Warranty is in lieu of all other warranties or conditions
whether expressed or implied including but not limited to
those of merchantability or fitness for purpose and shall
constitute the sole remedy of the Purchaser and the sole
liability of the Manufacturer in respect of the sale of the
product, whether in the nature of breach or breach of
fundamental term, or of negligence or otherwise.
The Manufacturer shall not be liable for any special, indirect
or consequential damages or for any damages resulting from
removal or replacement of a heater subject to warranty claim
without the Manufacturer’s authorization.
This Warranty is transferable by the original consumer
purchaser of the product. Any claims under this Warranty
must be submitted in writing to the Service Manager, Dimplex
North America Ltd., 1367 Industrial Rd., Cambridge, Ontario
N1R 7G8, Canada.
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0441050100RP
Blower Blade . . . . . . . . . . . . . . . . . . . . . . . . . 5300270100RP
Blower Motor . . . . . . . . . . . . . . . . . . . . . . . . . 2000410100RP
Power Board . . . . . . . . . . . . . . . . . . . . . . . . . 3000980100RP
Display Board . . . . . . . . . . . . . . . . . . . . . . . . 3001040100RP
2000W Element . . . . . . . . . . . . . . . . . . . . . . . 2203550200RP
Front Grille . . . . . . . . . . . . . . . . . . . . . . . . . . . 1024710100RP
Spacer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1026500100RP
Optional Accessories
Surface Mount Box . . . . . . . . . . . . . . . . . . . . . . . . .PCHSBW
CONNEX
TM
Controllers
Single Controller . . . . . . . . . . . . . . . . . . . . . . . DPCRWS
Multi-zone Controller . . . . . . . . . . . . . . . . . . . . CX-MPC
Replacement Parts
WARNING:
Always disconnect power at the circuit
breaker to the unit prior to performing any maintenance or
service operation.
CAUTION:
Allow adequate time for the element and body
casing to cool before attempting to work on the heater.
It is suggested that the heater be inspected regularly, for
cleanliness of the air filter and fan exhaust grille, to ensure
optimal performance is maintained. Both the filter and grille
can be cleaned by:
• Vacuuming off all dust and dirt or,
• Washing the filter in warm, soapy water and al-
lowing to dry thoroughly before reinstalling.
Once cleaning is complete replace the grille and filter, and
restore power.
!
NOTE:
NEVER operate the heater without the filter and
front grille in place.
At least at yearly intervals the wire connection condition
should be inspected to ensure full electrical continuity and
optimal performance is maintained.
WARNING:
The user can perform cleaning ONLY. All
other servicing should be performed by qualified service
personnel.
Maintenance
To Disable:
Within 5 seconds press
–
, then
✚
, then
–
,
then
✚
. The icon will disappear.
!
NOTE:
The PCH can be locked in either the Comfort or
Economy Setting. Ensure that the desired icons are present
when locking is complete.
Boost Function
The PCH is also equipped with a “Boost Function” which al-
lows the user to run the unit at full heat, for a predetermined
amount of time, to quickly heat up a cold room/space. The
Boost can be set for a maximum of 20 minutes, in 5 minute
increments.
To enable Boost:
1. Press and hold
✚
for 5 seconds. The area where the
temperature normally displays will begin to toggle be-
tween the display of “HI” and “20”.
!
NOTE:
The “20” indicates the time (in minutes) remaining
in Boost function. The timer is updated as the time counts
down 19, 18, 17, etc.
2. The length of time that Boost is enabled for can be
adjusted by pressing the
✚
or
–
buttons. Every time the
✚
or
–
button is pressed the timer will be adjusted by 5
minutes and will cycle back to 20 minutes.
3. When the timer times out the heater will return to the
programmed settings.
!
NOTE:
At any time you can hold down the
–
button for 5
seconds and exit the Boost function.