background image

 Operation

Figure 4

C

E F

G

H

I

A - Setting/Temperature Display

B - Comfort Setting Icon

C - Economy Setting Icon 

D - Set Back Temperature Setting

E - Synchronized Icon

F - Lock Icon

G - Decrease Button

H - Increase Button

I - Menu Button

A

D

B

  

WARNING: 

This heater is factory prewired for operation 

with the built-in thermostat. THIS HEATER IS NOT TO BE 

USED WITH A REGULAR WALL THERMOSTAT.

 CAUTION: 

This heater must be properly installed before 

it is used.
The PCH is a Precision Comfort Heater, which maintains a 

constant room temperature through the continuous addition 

of heat by the blowing of air into the room based on the set-

ting of the thermostat. The PCH operates such that once the 

room reaches the set point, the fan and heater 

will continu-

ously run 

at a low level, to maintain the desired room tem-

perature. If the temperature in the room rises, i.e. sun coming 

through a window, the fan will slow further and the temper-

ature of the heater will reduce so that the temperature of the 

room will continue to be the same. 

!

 NOTE: 

The element retains heat after shutdown, there 

is a built in cool down period of 2 ½ minutes before the fan 

shuts off completely.

  

WARNING:

 Should the Over Temp light come on, discon-

nect power to the heater and call a licensed electrician. 

DO NOT USE HEATER UNTIL THE CAUSE OF THE 

PROBLEM IS DETERMINED AND FIXED. 

Manual Controls

(See Figure 4 for display reference)
When power is first supplied to the PCH the Setpoint Tem-

perature will flash in the temperature display area. At any 

time either the 

 or 

 

button can be pressed to have the 

temperature setpoint displayed again.

A. Setting/Temperature Display 

 

The PCH is designed to control the temperature of a room 

anywhere from 32-86°F (0-30°C).  By pressing the 

 or 

 

will increase or decrease the desired temperature for the 

room to be heated by 0.5° (in either °C or °F).
After 5 seconds the Setpoint Temperature will switch to dis-

play the ambient temperature of the room.

!

 NOTE: 

Pressing the

 

 and 

 at the same time will toggle 

between °C and °F.

3

B. Comfort Setting

 

The Comfort Setting icon will be displayed when the heater 

is in normal operation based on the Setpoint Temperature for 

the room.

!

 NOTE:

 Either the   or   icon will always be visible, de-

pendent on the setting being used.

C. Economy Setting

 

The Economy Setting can be used to change the Setpoint 

Temperature for a user determined period of time. By press-

ing the 

V

 the Economy Setting will be enabled - signified by 

the icon flashing. After the Set Back Temperature has been 

set, the icon will become solid after three seconds and the 

Set Back Temperature will be enabled.
To return back to the Comfort Setting press the 

V

 button. The 

 icon will disappear and the   icon will appear. 

D. Set Back Temperature Setting

 

The Set Back Temperature Setting is used during periods 

when the Economy setting feature is active. This temperature 

adjustment can be set by pressing the 

V

 followed by the 

 

or 

E. Synchronized Icon

 

The PCH features CONNEX

TM

, a wireless technology that 

works with Dimplex single and multi-zone CONNEX

TM

 con-

trollers to provide simple whole home connectivity and com-

fort. CONNEX

TM

 controllers are available to control one or 

multiple Precision Comfort Heaters within a 50’ (15 m) radius. 

In order for the controller to have this function the PCH and 

the controller will need to be synchronized. To do this:
1.  On the PCH heater press and hold the 

V

 button for 3 

seconds, both the 

 and   icons will begin to flash.

2.  Press the 

 , 

 and then 

V

, on the PCH heater.

3.  Within 10 seconds press any button once on the CON-

NEX

TM

 Controller.

!

 NOTE:

 There is a 3 second delay between pressing the 

last button on the controller and the PCH heater.

!

 NOTE:

 To desynchronize a PCH heater from the synchro-

nized CONNEX

TM

 Controller; on either the PCH heater or the 

controller:

1. Press and hold the

 V

 for 3 seconds.

2. Press the 

V

 and then 

.

Nothing will need to be done to the other component.
Dimplex single and multi-zone CONNEX

TM

 controllers are 

sold separately and are available for purchase from your 

authorized Dimplex dealer.
To find your local Dimplex dealer, visit www.dimplex.com.

F. Lock Icon

 

The PCH has a Lock feature to prevent settings from acci-

dentally being changed.
1.  Press and hold the 

V

 for 3 seconds. Both the 

 and   

Icons will begin to flash.

2.  To Enable: 

Within 5 seconds press 

, then 

, then 

then 

. The   icon will appear