LIH 26TE
12 Device Information
1
Type and order code
LIH 26TE
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
IP21
2.2
Installation Location
Indoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
°C / °C
Up to 75 / above 18
Air
°C
-25 to +35
3.2
Temperature spread
of heating water
at A2 / W35
8.4
5.0
3.3
Heat output / COP
at A-7 / W35
1
kW / ---
1. This data indicates the size and capacity of the system according to EN 255 and EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters,
such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following
meaning: 2 °C external air temperature and 55 °C heating water flow temperature.
13.0 / 2.8
12.9 / 2.6
at A2 / W35
1
kW / ---
15.9 / 3.2
15.7 / 3.0
at A-7 / W75
1
kW / ---
18.1 / 1.8
18.0 / 1.7
at A7 / W35
1
kW / ---
19.8 / 3.8
19.5 / 3.6
at A10 / W35
1
kW / ---
20.4 / 3.9
20.2 / 3.7
3.4
Sound power level device / outdoors
dB(A)
62 / 68
3.5
Sound pressure level at a distance of 1 m (indoors)
dB(A)
58
3.6
Heating water flow
with an internal pressure differential of
m³/h / Pa
1.8 / 3700
2.7 / 8200
3.7
Air flow rate
with an external static pressure differential of
m³/h / Pa
9000 / 0
m³/h / Pa
8000 / 25
3.8
Refrigerant / total filling weight
type / kg
R404A / 3.7
R134a / 3.1
3.9
Lubricant; total filling weight (R404A)
type / litres (R404A)
Polyolester / 1.9
type / litres (R134a)
Polyolester / 1.77
4
Dimensions, connections and weight
4.1
Device dimensions
H x W x L cm
171 x 75 x 103
4.2
Device connections to heating system
Inch
G 1 1/4" external
4.3
Air duct inlet and outlet (min. internal dimensions)
L x W cm
72.5 x 72.5
4.4
Weight of the transportable unit(s) incl. packing
kg
389
5
Electrical connection
5.1
Nominal voltage; fuse protection
V / A
400 / 25 T
5.2
Nominal power consumption
1
A2 W35
kW
5.0
5.16
5.3
Starting current with soft starter
A
30
5.4
Nominal current A2 W35 / cos
A / ---
9.0 / 0.8
9.3 / 0.8
6
Complies with the European safety regulations
2
2. See CE declaration of conformity
7
Additional model features
7.1
Defrosting
Automatic
Type of defrosting
Reverse cycle
Defrosting tray included
Yes (heated)
7.2
Heating water in device protected against icing
3
3. The heat circulating pump and the heat pump manager must always be ready for operation.
Yes
7.3
Performance levels
2
7.4
Controller internal/external
Internal
Summary of Contents for LIH 26TE
Page 2: ......
Page 26: ...EN 11 452160 66 15 FD 9310 www dimplex de English LIH 26TE ...
Page 53: ...www dimplex de 452160 66 15 FD 9310 A XIV Anhang Appendix Annexes LIH 26TE ...
Page 54: ...A XV 452160 66 15 FD 9310 www dimplex de Anhang Appendix Annexes LIH 26TE ...
Page 55: ...www dimplex de 452160 66 15 FD 9310 A XVI Anhang Appendix Annexes LIH 26TE ...