www.dimplex.de
EN-27
Englis
h
13.4
13.4 LIA 14IM
Item
Unit
Outdoor Unit
Model code
LIAV 14IM
Performance Test Condition
EUROVENT
Heating Capacity
kW
14.00
BTU/h
47800
kJ/h
50400
Heating Capacity / COP
in acc.to EN 14511
A7/W35
kW / ---
14.00/4.50
A2/W35
kW / ---
12.40/3.32
A-7/W35
kW / ---
10.70/2.62
A-7/W55
kW / ---
8.50/1.79
A-15/W35
kW / ---
9.50/2.35
COP
W/W
4.50
BTU/hW
15.4
Noise Level distance 1,0 m, hight 1,5 m, A7/W35, 50 Hz
dB(A)
51
Power Level dB
68
Air Flow
m³/min (ft³/min)
84.0 (2970)
Refrigeration Control Device
Expansion Valve
Refrigerant Oil
cm³
FV50S (1200)
Refrigerant (R410A)
kg (oz)
2.95k (104.1)
Dimension
Height
mm (inch)
1340 (52-3/4)
Width
mm (inch)
900 (35-7/16)
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
106 (234)
Pipe Diameter
Liquid
mm (inch)
9.52 (3/8)
Gas
mm (inch)
15.88 (5/8)
Standard Length
m (ft)
7 (23.0)
Pipe Length Range
m (ft)
3 (9.8) ~ 40 (131.2)
I/D&O/D Hight Difference
m (ft)
30 (98.4)
Additional Gas Amount
g/m (oz/ft)
50 (0.5)
Refrigeration Charge Less
m (ft)
30 (98.4)
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Rated Output
kW
3.00
Fan
Type
Propeller Fan
Material
PP
Motor Type
Induction (8-poles)
Input Power
W
--
Output Power
W
60
Fan Speed
rpm
540 (Top Fan) 580 (Bottom Fan)
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 51 x 18
Size (W x H x L)
mm
881.5 x 1295.4 x 44
Power Source (Phase, Voltage, Cycle)
Ø
Single
V
230
Hz
50
Input Power
kW
3.11
Maximum Input Power for Heat Pump System
kW
5.52
Maximum Input Power for Internal Heater
(Internal Tank Heater)
kW
6.00 (9.00)
Starting Current
A
14.1
Running Current
A
14.1
Maximum Current for Heat Pump System
A
25.0
Maximum Current for Internal Heater
(Internal Tank Heater)
A
26 (39)
Power Factor
%
96
Power Factor means total figure of compressor and outdoor fan motor.
Power Cord
Number of core
--
Length
m (ft)
--
Thermostat
Electronic Control
Protection Device
Electronic Control
Summary of Contents for LIA 12IM
Page 2: ......