EN-4 452161.66.02 · FD 9601
www.dimplex.de
English
LI 9TES
3 Scope of Delivery
3.1 Basic Device
The heat pump contains the components listed below.
The refrigerant circuit is hermetically sealed. It contains the
Kyoto protocol approved refrigerant R410A with a GWP value of
2088. It is CFC-free, does not deplete ozone and is non-flamma-
ble.
1)
Evaporator
2)
Ventilator
3)
Compressor
4)
Switch box
5)
Expansion valve
6)
Filter dryer
7)
Liquifier
3.2 Switch Box
ATTENTION!
Before opening the device, ensure that all circuits are isolated from the
power supply.
The switch box is located in the heat pump. It can be swung out
after removing the lower front cover and loosening the fastening
screw located in the upper right-hand corner.
The switch box contains the supply connection terminals, as well
the power contactors, the soft starter unit and the heat pump
manager.
The heat pump manager is a convenient electronic regulation
and control device. It controls and monitors the entire heating
system on the basis of the external temperature, including hot
water preparation and safety systems.
The customer must install the external temperature sensor,
which is included in the scope of supply of the heat pump man-
ager together with the necessary fixing accessories.
The enclosed operating instructions describe the function and
use of the heat pump manager.
3.3 Accessories Pack
Contents:
2
Sealing rings for duct connection
2
Fixing brackets
2
10-mm dowels
2
8 x 80 screws
4
M4 x 8 screws
Summary of Contents for LI 9TES
Page 2: ......
Page 34: ...EN 16 452161 66 02 FD 9601 www dimplex de English LI 9TES ...
Page 50: ...FR 16 452161 66 02 FD 9601 www dimplex de Français LI 9TES ...
Page 66: ...A XVI 452161 66 02 FD 9601 www dimplex de Anhang Appendix Annexes LI 9TES ...
Page 67: ...www dimplex de 452161 66 02 FD 9601 A XVII Anhang Appendix Annexes LI 9TES ...