Luft/Wasser-
Wärmepumpe für 
Innenaufstellung

LI 9TES

Air-to-Water 
Heat Pump for 
Indoor Installation

Pompe à chaleur 
air-eau pour 
installation 
intérieure

Montage- und 
Gebrauchsanweisung

Deutsch

English

Français

Instructions d’installation 
et d’utilisation

Installation and
Operating Instructions

Bestell-Nr. / Order no. / N

o

 de commande : 452161.66.02

FD 9601

Summary of Contents for LI 9TES

Page 1: ...p for Indoor Installation Pompe à chaleur air eau pour installation intérieure Montage und Gebrauchsanweisung Deutsch English Français Instructions d installation et d utilisation Installation and Operating Instructions Bestell Nr Order no No de commande 452161 66 02 FD 9601 ...

Page 2: ......

Page 3: ... 6 6 3 Schall DE 6 7 Montage DE 7 7 1 Allgemein DE 7 7 2 Luftanschluss DE 7 7 3 Heizungsseitiger Anschluss DE 9 7 4 Temperaturfühler DE 10 7 5 Elektrischer Anschluss DE 11 8 Inbetriebnahme DE 12 8 1 Allgemein DE 12 8 2 Vorbereitung DE 12 8 3 Vorgehensweise DE 12 9 Reinigung Pflege DE 13 9 1 Pflege DE 13 9 2 Reinigung Heizungsseite DE 13 9 3 Reinigung Luftseite DE 13 10 Störungen Fehlersuche DE 13 ...

Page 4: ...gehender Gebrauch gilt als nicht bestimmungsgemäß Dazu zählt auch die Beachtung der zugehörigen Projektierungsunter lagen Änderungen oder Umbauten am Gerät sind zu unterlas sen 1 3 Gesetzliche Vorschriften und Richtlinien Diese Wärmepumpe ist gemäß Artikel 1 Abschnitt 2 k der EG Richtlinie 2006 42 EC Maschinenrichtlinie für den Gebrauch im häuslichen Umfeld bestimmt und unterliegt damit den Anford...

Page 5: ...en monoenergetischen und bivalenten Betrieb bis 20 C Luftaußentemperatur geeignet Im Dauerlauf ist eine Temperatur des Heizwasserrücklaufs von mehr als 18 C einzuhalten um ein einwandfreies Abtauen des Verdampfers zu gewährleisten Die Wärmepumpe ist nicht ausgelegt für den erhöhten Wärme bedarf während der Bauaustrocknung deshalb muss der zusätz liche Wärmebedarf mit speziellen bauseitigen Geräten...

Page 6: ...Frontabdeckung und dem Lösen der sich rechts oben befindenden Befestigungsschraube kann der Schaltkasten herausgeklappt werden Im Schaltkasten befinden sich die Netzanschlussklemmen sowie die Leistungsschütze die Sanftanlauf Einheit und der Wärmepumpenmanager Der Wärmepumpenmanager ist ein komfortables elektronisches Regel und Steuergerät Er steuert und überwacht die gesamte Heizungsanlage in Abhä...

Page 7: ...ch den vorhandenen Zusatzwärmetauscher werden für die Erfassung der Wärmemenge zwei Wärmemengenzähler benö tigt Sensoren im Vor und Rücklauf der Wärmetauscherleitungen und ein Elektronikmodul erfassen die gemessenen Werte und übertragen ein Signal an den Wärmepumpenmanager der ab hängig von der aktuellen Betriebsart der Wärmepumpe Heizen Warmwasser Schwimmbad die Wärmemenge in kWh aufsum miert und...

Page 8: ...t sein dass Wartungsarbeiten problemlos durchgeführt werden kön nen Dies ist gewährleistet wenn ein Abstand von je 1 m an der Frontseite und links der Wärmepumpe eingehalten wird Die Sei tenteile dürfen nicht durch Anschlussleitungen verdeckt sein Das Gerät sollte nie in Räumen mit hoher Luftfeuchtigkeit aufge stellt werden Bei Luftfeuchtigkeiten von über 50 und Außen temperaturen unter 0 C kann a...

Page 9: ... berührt lediglich der Dichtgummi die Wärmepumpe Da durch ist zum einen eine leichte Montage und Demontage der Wärmepumpe gewährleistet zum anderen wird eine gute Kör perschallentkopplung erreicht Ansonsten ist darauf zu achten dass der Mauerdurchbruch auf der Innenseite zwingend mit einer Kälteisolierung verkleidet wird um eine Auskühlung bzw Durchfeuchtung des Mauerwerks zu verhindern Das beilie...

Page 10: ...nd Federring an vier Ecken des Ventilators lösen 5 Ventilator etwa eine Düsenlänge ins Gerät ziehen und nach vorne aus dem Gerät herausnehmen Verdampfer vor Be schädigung schützen 6 Dichtstopfen aus hinterer Kabelverschraubung der Konden satwanne entnehmen und in vordere Verschraubung einset zen 7 Ventilator auf gleiche Weise wieder von links ins Gerät schieben und nach hinten auf vorhandene Schra...

Page 11: ...er minimal zulässige pH Wert von 7 5 minimal zulässiger Wert für Kupfer nicht unterschritten wird Eine Unterschreitung kann zur Zerstörung der Wärmepumpe führen Mindestheizwasserdurchsatz Der Mindestheizwasserdurchsatz der Wärmepumpe ist in jedem Betriebszustand der Heizungsanlage sicherzustellen Dieses kann z B durch Installation eines doppelt differenzdrucklosen Verteilers oder eines Überströmve...

Page 12: ...ind Die Anlegefühler können als Rohranlegefühler montiert oder in die Tauchhülse des Kompaktverteilers eingesetzt werden Montage als Rohranlagefühler Heizungsrohr von Lack Rost und Zunder säubern Gereinigte Fläche mit Wärmeleitpaste bestreichen dünn auftragen Fühler mit Schlauchschelle befestigen gut festziehen lose Fühler führen zu Fehlfunktionen und thermisch isolieren 7 4 4 Verteilsystem Hydrau...

Page 13: ...ichert werden Die Versorgungsleitung L N PE 230 V 50 Hz für den WPM muss an Dauerspannung liegen und ist aus diesem Grund vor dem EVU Sperrschütz abzugreifen bzw an den Haushaltsstrom anzuschließen da sonst während der EVU Sperre wichtige Schutzfunktionen außer Betrieb sind 3 Das EVU Sperrschütz K22 mit 3 Hauptkontakten 1 3 5 2 4 6 und einem Hilfskontakt Schließer 13 14 ist entspre chend der Wärme...

Page 14: ... ist so weit zu öffnen dass sich bei der aktu ellen Wärmequellentemperatur die in der nachstehenden Ta belle angegebene maximale Temperaturspreizung zwischen Heizungsvor und Rücklauf ergibt Die Temperaturspreizung ist möglichst nahe an der Wärmepumpe zu messen Bei monoener getischen Anlagen ist der Heizstab während der Inbetriebnahme zu deaktivieren Bei Heizwassertemperaturen kleiner 7 C ist eine ...

Page 15: ...äurehaltiges Reinigungsmittel in den Heizungsanlagenkreislauf gelangt empfehlen wir das Spülgerät direkt an den Vor und Rücklauf des Verflüssigers der Wärme pumpe anzuschließen Danach muss mit geeigneten neutralisierenden Mitteln gründlich nachgespült werden um Beschädigungen durch eventuell im System verbliebene Reinigungsmittelreste zu verhindern Die Säuren sind mit Vorsicht anzuwenden und es si...

Page 16: ...x B x T mm 1250 x 750 x 680 5 2 Gewicht der Transporteinheit en inkl Verpackung kg 181 5 3 Geräteanschlüsse für Heizung Zoll R 1 5 4 Luftkanalanschluss Ansaugseite mm 440 x 440 Luftkanalanschluss Ausblasseite mm 440 x 440 5 5 Kältemittel Gesamt Füllgewicht Typ kg R410A 1 9 5 6 Schmiermittel Gesamt Füllmenge Typ Liter Polyolester POE 1 2 5 7 Volumen Heizwasser im Gerät Liter 3 2 6 Elektrischer Ansc...

Page 17: ...uziert werden Umverdrahtung des Lüfters von Dreieck auf Stern 3 Der angegebene Schalldruckpegel entspricht dem Betriebsgeräusch der Wärmepumpe im Heizbetrieb bei 35 C Vorlauftemperatur Der angegebene Schalldruckpegel stellt den Freifeldpegel dar Je nach Aufstellunsort kann der Messwert um bis zu 16 dB A abweichen 4 Beachten Sie daß der Platzbedarf für Rohranschluss Bedienung und Wartung größer ist...

Page 18: ...ieferer bezogene Teile und Geräte Anlagenmängel die auf nicht vom Lieferer bezogene Teile zurückzu führen sind fallen nicht unter den Garantieanspruch Bei endgültig fehlgeschlagener Nachbesserung wird der Hersteller entweder kostenfreien Ersatz liefern oder den Minderwert vergüten Im Falle einer Ersatzlieferung behalten wir uns die Geltendmachung einer angemessenen Nutzungsanrechnung für die bishe...

Page 19: ...Pipe EN 6 6 3 Sound EN 6 7 Installation EN 7 7 1 General Information EN 7 7 2 Air Connection EN 7 7 3 Heating System Connection EN 9 7 4 Temperature sensor EN 10 7 5 Electrical connection EN 11 8 Start UP EN 12 8 1 General Information EN 12 8 2 Preparation EN 12 8 3 Procedure EN 12 9 Maintenance Cleaning EN 13 9 1 Maintenance EN 13 9 2 Cleaning the Heating System EN 13 9 3 Cleaning the Air System ...

Page 20: ... Any other use beyond that intended by the manufacturer is prohibited This requires the user to abide by the relevant project planning documents Please refrain from tampering with or alter ing the device 1 3 Legal Regulations and Directives This heat pump is designed for use in a domestic environment according to Article 1 Paragraph 2 k of EC directive 2006 42 EC machinery directive and is thus su...

Page 21: ...an external temperature of 20 C Proper defrosting of the evaporator is guaranteed by maintaining a heating water return flow temperature of more than 18 C dur ing continuous operation The heat pump is not designed for the increased heat consump tion required when a building is being dried out The additional heat consumption should be met using special devices provided by the customer If a building...

Page 22: ...front cover and loosening the fastening screw located in the upper right hand corner The switch box contains the supply connection terminals as well the power contactors the soft starter unit and the heat pump manager The heat pump manager is a convenient electronic regulation and control device It controls and monitors the entire heating system on the basis of the external temperature including h...

Page 23: ...r two thermal en ergy meters are required for measuring the quantity of thermal energy Sensors in the flow and return of the heat exchanger pipes and an electronics module acquire the measured values and transmit a signal to the heat pump manager which depending on the cur rent operating mode of the heat pump heating DHW swimming pool totals the thermal energy in kWh and displays them in the opera...

Page 24: ...ied out without being hindered This can be ensured by maintaining a clearance of 1 m in front and to the left of the heat pump The side panel assemblies must not be covered by connecting pipes Never install the device in rooms subject to high humidity Con densation can form on the heat pump and air circuit if the humid ity exceeds 50 and the external temperature is below 0 C Neither frost nor temp...

Page 25: ...nto the heat pump Only the rubber seal comes into direct contact with the heat pump when the system is installed correctly This guarantees easy as sembly and disassembly of the heat pump and also ensures that solid borne sound is well insulated It must also be ensured that the interior side of the wall opening is lined with thermal insulation to prevent the wall from becoming cold and to prevent m...

Page 26: ...box nozzle panel and condensate drain 4 Loosen the nut and washers on the four corners of the fan 5 Pull the fan one nozzle length into the device and pull it out through the front of the device Protect evaporators from damage 6 Remove the sealing plugs from the rear condensate tray cable gland and insert them into the front screw joints 7 Insert the fan back into the device from the left and onto...

Page 27: ...7 5 minimum permissible value for copper is complied with Failure to comply with this value can result in the heat pump being destroyed Minimum heating water flow rate The minimum heating water flow rate through the heat pump must be assured in all operating states of the heating system This can be accomplished for example by installing either a dual differential pressureless manifold or an overfl...

Page 28: ... installed The strap on sensors can be fitted as pipe mounted sensors or installed in the immersion sleeve of the compact manifold Mounting as a pipe mounted sensor Remove paint rust and scale from heating pipe Coat the cleaned surface with heat transfer compound apply sparingly Attach the sensor with a hose clip tighten firmly as loose sensors can cause malfunctions and thermally insulate 7 4 4 H...

Page 29: ...oltage must be ensured according to the type plate The L N PE 230 V 50 Hz supply cable for the heat pump manager must have a constant voltage For this reason it should be tapped upstream from the utility blocking contactor or be connected to the household current as important protection functions may otherwise be lost during a utility block 3 The utility blocking contactor K22 with 3 main contacts...

Page 30: ...g At least one heating circuit must remain open e g bathroom The overflow valve should be opened far enough to produce the maximum temperature spread between the heating flow and re turn flow listed in the following table for the current heat source temperature The temperature spread should be measured as close as possible to the heat pump The heating element of mono energy systems should be disco...

Page 31: ...osite to the normal flow direction To prevent acidic cleaning agents from entering the heating sys tem circuit we recommend connecting the flushing device di rectly to the flow and return flow of the liquifier of the heat pump It is important that the system be thoroughly flushed using appro priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in t...

Page 32: ...ght of the transportable unit s incl packaging kg 181 5 3 Device connections for heating system Inches R 1 5 4 Air duct connection air intake side mm 440 x 440 Air duct connection air outlet side mm 440 x 440 5 5 Refrigerant total filling weight type kg R410A 1 9 5 6 Lubricant total filling quantity type litres Polyolester POE 1 2 5 7 Volume of heating water in device litres 3 2 6 Electrical conne...

Page 33: ... sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 C The specified sound pressure level represents the free sound area level The measured value can deviate by up to 16 dB A depending on the installation location 4 Please note that additional space is required for pipe connections operation and maintenance 5 These data indica...

Page 34: ...EN 16 452161 66 02 FD 9601 www dimplex de English LI 9TES ...

Page 35: ...2 Ecoulement des condensats FR 6 6 3 Bruit FR 7 7 Installation FR 7 7 1 Remarques d ordre général FR 7 7 2 Prise d air FR 7 7 3 Raccordement côté chauffage FR 9 7 4 Sonde de température FR 10 7 5 Branchements électriques FR 11 8 Mise en service FR 12 8 1 Remarques d ordre général FR 12 8 2 Préparation FR 12 8 3 Procédures à suivre FR 12 9 Nettoyage entretien FR 13 9 1 Entretien FR 13 9 2 Nettoyage...

Page 36: ... est considérée comme non conforme La documentation accompagnant les projets doit également être prise en compte Toute modification ou transfor mation sur l appareil est à proscrire 1 3 Dispositions légales et directives Cette pompe à chaleur est conçue pour une utilisation dans un environnement domestique selon l article 1 paragraphe 2 k de la directive CE 2006 42 CE directive relative aux machin...

Page 37: ...ns nouvelles La pompe à chaleur convient pour un fonctionnement en mode mono énergétique et bivalent jusqu à des températures extérieures de 20 C Une température du retour de l eau de chauffage de plus de 18 C doit être maintenue en fonctionnement continu pour ga rantir un dégivrage optimal de l évaporateur La pompe à chaleur n est pas conçue pour le besoin en chaleur élevé requis pour le séchage ...

Page 38: ... et dévissé la vis de fixation se trouvant en haut à droite Dans le boîtier électrique se trouvent les bornes de connexion au secteur ainsi que les contacteurs de puissance l unité de démar rage progressif et le gestionnaire de pompe à chaleur Le gestionnaire de pompe à chaleur est un appareil de com mande et de régulation électronique facile à utiliser Il commande et surveille toute l installatio...

Page 39: ...échangeur thermique Des capteurs situés dans les circuits de départ et de retour des conduites de l échangeur thermique et un module électronique saisissent les données mesurées et transmettent un message au gestionnaire de pompe à chaleur qui en fonction du mode ac tuel de la pompe à chaleur chauffage eau chaude sanitaire eau de piscine additionne la quantité de chaleur en kWh et affiche le résul...

Page 40: ... d absorption acoustique com plémentaires seront éventuellement nécessaires Si l installation se fait sur un réservoir tampon sous jacent il est obligatoire que la pompe à chaleur repose sur toute sa surface La pompe à cha leur doit être installée de telle façon que les travaux d entretien puissent s effectuer sans problèmes Ce qui est le cas si on ob serve respectivement un écartement d un mètre ...

Page 41: ...sés comme accessoires sont résistants à l humidité et ouverts à la diffusion L embout d étanchéité est utilisé pour étancher les conduits d air sur la pompe à chaleur Les conduits d air par eux mêmes ne sont pas vissés directement sur la pompe à chaleur Lorsque l installation est mise en place prête à fonctionner seul le joint d étanchéité en caoutchouc touche la pompe à chaleur De cette manière d...

Page 42: ...s aux quatre coins du ventilateur 5 Tirer le ventilateur vers l intérieur de l appareil sur environ une longueur de buse puis le sortir par l avant de l appareil Si besoin est protéger l évaporateur de tout endommage ment 6 Retirer le bouchon d étanchéité du presse étoupe arrière de la cuve de condensats et le placer dans le presse étoupe avant 7 Replacer le ventilateur dans l appareil par la gauc...

Page 43: ...éminéralisée à ce que le seuil inférieur admis pour la valeur pH minimale de 7 5 valeur minimale admise pour le cuivre ne soit pas dépassé Un tel dépassement peut entraîner la destruction de la pompe à chaleur Débit d eau de chauffage minimum Le débit minimum d eau de chauffage doit être garanti dans la pompe à chaleur quel que soit l état de fonctionnement de l ins tallation de chauffage C est to...

Page 44: ...applique peuvent être montées sur les tuyauteries ou insérées dans le doigt de gant du distributeur compact Montage sur les tuyauteries Nettoyer les tuyaux de chauffage des restes de peinture éliminer la rouille et les taches d oxydation Enduire les surfaces nettoyées de pâte thermoconductrice appliquer en fine couche La sonde doit être fixée avec un collier pour flexibles serrer à fond des sondes...

Page 45: ...ssance à 4 kW ou 2 kW les ponts en cuivre doivent être retirés conformément au schéma électrique Pour des informations plus détaillées voir les schémas élec triques en annexe Chap 3 2 à la page VII 2 La ligne d alimentation électrique à 3 fils du gestionnaire de pompe à chaleur régulateur de chauffage N1 est amenée à la pompe à chaleur La tension de commande doit être sécurisée conformément à la p...

Page 46: ...ous vous conseillons de procéder de la manière suivante Fermez tous les circuits de chauffage pouvant l être en phase de fonctionnement selon l utilisation qu il en est faite ceci ayant pour but d obtenir le débit d eau le plus défavorable En règle gé nérale ce sont les circuits de chauffage des locaux donnant sur le côté sud et ouest Au moins un des circuits de chauffage doit rester ouvert par ex...

Page 47: ...t Pour éviter l infiltration de nettoyant contenant de l acide dans le circuit de l installation de chauffage nous vous recommandons de raccorder l appareil de nettoyage directement sur le départ et le retour du condenseur de la pompe à chaleur Il faut ensuite soigneusement rincer à l aide de produits neutrali sants adéquats afin d éviter tous dommages provoqués par d éventuels restes de produits ...

Page 48: ... 181 5 3 Raccordements de l appareil de chauffage pouces filet 1 5 4 Raccordement à la gaine d air côté aspiration mm 440 x 440 Raccordement à la gaine d air côté évacuation mm 440 x 440 5 5 Fluide frigorigène poids total au remplissage type kg R410A 1 9 5 6 Lubrifiant capacité totale type litres Polyolester POE 1 2 5 7 Volume d eau de chauffage dans l appareil litres 3 2 6 Branchements électrique...

Page 49: ...a n entraîne toutefois pas de réduction du COP ou de perte de puissance 3 Le niveau de pression sonore indiqué correspond au bruit de fonctionnement de la pompe à chaleur en mode chauffage à une température départ de 35 C Le niveau de pression sonore indiqué est celui d une propagation de champ libre Selon le lieu d installation la valeur mesurée peut varier de 16 dB A max 4 Noter que la place néc...

Page 50: ...FR 16 452161 66 02 FD 9601 www dimplex de Français LI 9TES ...

Page 51: ...bindungsschemen Hydraulic integration diagrams Schéma d intégration hydrauliques A XI 4 1 Monoenergetische Anlage mit einem Heizkreis Mono energy system with one heating circuits Installation mono énergétique avec un circuits de chauffage A XI 4 2 Monoenergetische Anlage mit zwei Heizkreisen und Warmwasserbereitung Mono energy system with two heating circuits and domestic hot water preparation Ins...

Page 52: ...ORZ LQVLGH PP HDWLQJ ZDWHU IORZ HDW SXPS RXWOHW H WHUQDO WKUHDG HDWLQJ ZDWHU UHWXUQ IORZ HDW SXPS LQOHW H WHUQDO WKUHDG OHFWULF OLQHV LQWHUQDO WKUHDG 0 FRXOHPHQW GX FRQGHQVDW LQW PP OOHU HDX GH FKDXIIDJH 6RUWLH GH OD 3 LOHWDJH H WpULHXU 5HWRXU HDX GH FKDXIIDJH QWUpH GDQV OD 3 LOHWDJH H WpULHXU LJQHV pOHFWULTXHV ILOHWDJH LQWpULHXU 0 RQGHQVDWDEODXI QQHQ PP RQGHQVDWH RXWIORZ LQVLGH PP FRXOHPHQW GX FR...

Page 53: ...RU RQGXLW G DpUDWLRQ GLVSRQLEOH HQ DFFHVVRLUH 8PODXIHQGH EVFKUlJXQJ EDXVHLWV XU EGLFKWXQJ GHU 6WR NDQWH XQG 9HUEHVVHUXQJ GHU XIWI KUXQJ RQWLQXRXV FKDPIHU WR EH SURYLGHG E WKH FXVWRPHU WR VHDO WKH ERUGHU DQG WR IDFLOLWDWH DLU FLUFXODWLRQ KDQIUHLQ SpULSKpULTXH j IRXUQLU SDU OH FOLHQW DVVXUDQW O pWDQFKpLWp GX ERUG HW DPpOLRUDQW OD FRQGXLWH GH O DLU HL LQVDW HLQHV lPPVWUHLIHQV RGHU 6WHOOI HQ XQWHU GHU...

Page 54: ...re in C Température de sortie de l eau en C Lufteintrittstemperatur in C Air inlet temperature in C Température d entrée d air en C Leistungsaufnahme in kW incl Pumpenleistungsanteil Power consumption in kW incl power input to pump Consommation de puissance en kW y compris part de consommation de la pompe Druckverlust in Pa Pressure loss in Pa Perte de pression en Pa Lufteintrittstemperatur in C A...

Page 55: ...llt dei minimale Heizwassertemperatur die Mindest Rücklauftemperatur dar For air to water heat pumps the minimum heating water temperature is the minimum return temperatur Sur les pompes à chaleur air eau la température minimale d eau de chauffage correspond à la température retoue minimale Wämequelleneintrittstemperatur C Heat source temperature inlet C Température d entrée de la source de chaleu...

Page 56: ...A VI 452161 66 02 FD 9601 www dimplex de Anhang Appendix Annexes LI 9TES 3 Stromlaufpläne Circuit Diagrams Schémas électriques 3 1 Steuerung Control Commande ...

Page 57: ...www dimplex de 452161 66 02 FD 9601 A VII Anhang Appendix Annexes LI 9TES 3 2 Last Load Charge ...

Page 58: ...A VIII 452161 66 02 FD 9601 www dimplex de Anhang Appendix Annexes LI 9TES 3 3 Anschlussplan Circuit Diagram Schéma électrique ...

Page 59: ...eingänge Analogue inputs Entrées analogiques J4 Analogausgänge Analogue outputs Sorties analogiques J5 Digitaleingänge Digital inputs Entrées numériques J6 Analogausgänge Analogue outputs Sorties analogiques J7 8 Digitaleingänge Digital inputs Entrées numériques J9 frei free libre J10 Bedienfeld Operating panel Panneau de commande J11 frei free libre J12 J18 230 V AC Ausgänge für die Ansteuerung d...

Page 60: ...onents must be connected supplied by the customer Les pièces sont à raccorder à fournir par le client ____ werkseitig verdrahtet wired ready for use câblé en usine bauseits nach Bedarf anzuschließen to be connected by the customer as required à raccorder par le client si besoin ACHTUNG An den Steckklemmen J1 bis J11 J24 bis J26 und der Klemmleiste X3 liegt Kleinspannung an Auf keinen Fall darf hie...

Page 61: ...aulische Einbindungsschemen Hydraulic integration diagrams Schéma d intégration hydrauliques 4 1 Monoenergetische Anlage mit einem Heizkreis Mono energy system with one heating circuits Installation mono énergétique avec un circuits de chauffage 9 1 5 1 7 1 1 0 0 0 1 1 1 1 1 5 7 7 ...

Page 62: ... zwei Heizkreisen und Warmwasserbereitung Mono energy system with two heating circuits and domestic hot water preparation Installation mono énergétique avec deux circuits de chauffage et production d eau chaude sanitaire 9 1 5 1 1 1 1 0 1 5 1 1 1 1 0 0 0 7 1 1 0 0 00 97 7 0 1 1 1 1 7 7 0 1 5 7 1 1 0 1 5 7 ...

Page 63: ...Heizkreisen und Warmwasserbereitung Bivalent system with two heating circuits and domestic hot water preparation Installation bivalente avec deux circuits de chauffage et production d eau chaude sanitaire 9 1 5 1 1 1 1 0 1 5 1 1 1 1 0 0 0 7 1 1 0 0 00 97 00 1 1 1 0 0 0 7 0 1 1 1 1 7 7 0 0 1 5 7 1 1 0 1 5 7 ...

Page 64: ...cher Buffer tank connected in series Ballon tampon en série Warmwasserspeicher Hot water cylinder Ballon d eau chaude sanitaire E9 Flanschheizung Warmwasser Flange heater hot water Cartouche chauffante ECS E10 1 Tauchheizkörper Immersion heater Résistance immergée E10 2 Öl Gaskessel Oil gas boiler Chaudière fuel gaz M13 Heizungsumwälzpumpe Hauptkreis Heat circulating pump for main circuit Circulat...

Page 65: ...g Wärmepumpen Designation Heat pumps Désignation Pompes à chaleur Typ LI 9TES Type s Type s EG Richtlinien Niederspannungsrichtlinie 2006 95 EG EMV Richtlinie 2004 108 EG Druckgeräterichtlinie 97 23 EG EC Directives Low voltage directive 2006 95 EC EMC directive 2004 108 EC Pressure equipment directive 97 23 EC Directives CEE Directive Basse Tension 2006 95 CE Directive CEM 2004 108 CE Directive É...

Page 66: ...A XVI 452161 66 02 FD 9601 www dimplex de Anhang Appendix Annexes LI 9TES ...

Page 67: ...www dimplex de 452161 66 02 FD 9601 A XVII Anhang Appendix Annexes LI 9TES ...

Page 68: ...tschland GmbH Geschäftsbereich Dimplex Am Goldenen Feld 18 D 95326 Kulmbach Irrtümer und Änderungen vorbehalten Subject to alterations and errors Sous réserve d erreurs et modifications 49 0 9221 709 565 www dimplex de ...