SETTING 3 – SPACE HEATING SETTINGS
HEAT
█
, H20, Lo
Press
S E L E C T
Press
▲▼
Set Temperature
55 °c
Press
S E T
to Store
Setting 4 Press
▼
SETTING 2 – SPACE HEATING SETTINGS
HEAT
█
, out, Hi
Press
S E L E C T
Press
▲▼
Set Temperature
15 °c
Press
S E T
to Store
Setting 3 Press
▼
SETTING 1 – SPACE HEATING SETTINGS
HEAT
█
, out, Lo
Press
S E L E C T
Press
▲▼
Set Temperature
0 °c
Press
S E T
to Store
Settings
Menu
– Parameter
Sets the low ambient air temperature to be used in
conjunction with higher water flow temperature required for
weather compensation.
0°C
– Sets the low ambient air temperature which
corresponds with the higher water flow temperature entered
in SETTING 3 BELOW.
Sets the high ambient air temperature to be used in
conjunction with lower water flow temperature required for
weather compensation.
15°C
– Sets high the ambient air temperature which
corresponds with the lower water flow temperature entered
in SETTING 4 BELOW.
Sets the high water flow temperature to be used in
conjunction with low ambient air temperature required for
weather compensation.
55°C
– Sets the high water flow temperature which
corresponds with the low ambient air temperature entered
in SETTING 1 ABOVE.
15
Summary of Contents for LA MI
Page 1: ...LA MI Settings Function Programming Overview 8 60381 0 1 ...
Page 3: ...Setting The Time 3 ...
Page 6: ...Pre Configuration 6 ...
Page 13: ...System Settings Menu Setting Parameters 13 ...
Page 18: ...Heat Pump On Running 18 ...
Page 20: ...Operating Mode Heater Enable Selection 20 ...
Page 25: ...LA MI Advanced Settings Timer Programming Overview 25 ...
Page 34: ...Completed 34 ...