OPTION 14 – STERILISATION CONTINUE TIME
StrL, oPr.
Press
SELECT
Press
▲▼
Set Duration
1 : 0 0
Press
S E T
to Store
Press
C A N C E L
to Escape
OPTION 13 – STERILISATION TEMPERATURE
StrL, boi.
Press
SELECT
Press
▲▼
Set Temperature
6 0°C
Press
S E T
to Store
Option 14 Press
▼
Pre
Configuration
– Hydraulic
Design
Sets the thermal disinfection temperature the immersion
heater will raise the hot water cylinder too.
6 0 °c
- the cylinder will be raised to 60C using the cylinder
immersion at 23.30 on Friday.
Sets the duration the hot water cylinder will be maintained at
the disinfection temperature for.
1 : 0 0
– the cylinder will be maintained at 60°C for 1h