E-8
English
11
11 Equipment Data
Equipment data for air-to-water heat pumps for heating
1
Type and commercial description
LA 11MS
LA 16MS
2
Model
2.1
Enclosure type acc. to EN 60 529 for compact unit or heating element
IP 24
IP 24
2.2
Installation site
outdoors
outdoors
3
Performance data
3.1
Operating temperature limits:
Heating water supply / return
1
°C / °C
1. See operating limits diagram
max. 55 / min. 18
max. 55 / min. 18
Air
°C
-20 to +35
-20 to +35
3.2
Heating water temperature difference at A2 / W35
7.8
7.8
3.3
Heating capacity / coeff. of perform. at A-7 / W35
2
kW / ---
2. These data characterize the size and performance of the system. For economic and energetic reasons, additional factors such as defrosting behaviour, bivalence point and control
need to be taken into consideration. Abbreviations have the following meaning, e.g. A2 / W55: outside temperature 2 °C and heating water supply temperature 55 °C.
7.6 / 2.9
9.8 / 2.6
at A2 / W35
kW / ---
9.1 / 3.4
12.7 / 3.2
at A2 / W50
kW / ---
9.0 / 2.5
12.2 / 2.4
at A7 / W35
kW / ---
10.9 / 4.1
15.4 / 3.7
at A10 / W35
kW / ---
12.0 / 4.6
16.1 / 3.8
3.4
Sound power level 4)
dB(A)
63
64
3.5
Sound pressure level at a distance of 10m (discharge end) dB(A)
33
34
3.6
Heating water flow rate at internal pressure difference
m³/h / Pa
1.0 / 3000
1.4 / 4500
3.7
Air flow rate
m³/h / Pa
2500
4000
3.8
Refrigerant; total charge weight
type / kg
R404A / 2.5
R404A / 3.1
4
Dimensions, connections and weight
4.1
Equipment dimensions
H x W x L cm
136 x 136 x 85
157 x 155 x 85
4.2
Equipment connections for heating
inches
G 1'' ext. thread
G 1'' ext. thread
4.3
Weight of transport unit(s) incl. packaging
kg
219
264
5
Electrical connection
5.1
Nominal voltage; fusing
V / A
230 / 25
230 / 32
5.2
A2 W35
kW
2.65
3.95
5.3
Starting current with soft starter
A
38
45
5.4
Nominal current A2 W35 / cos
ϕ
A / ---
14.4 / 0.8
21.5
6
Complies with european safety regulations
3
3. See EC Declaration of Conformity
7
Other design characteristics
7.1
Defrosting
automatic
automatic
Type of defrosting
cycle reversal
cycle reversal
Defrost pan available
yes (heated)
yes (heated)
7.2
Heating water inside unit protected against freezing
4
4. The heating circulating pump and the controller of the heat pump must be on standby at all times.
yes
yes
7.3
Performance settings
1
1
7.4
Controller internal / external
external
external
Summary of Contents for LA 11MS