![Dimplex IL095 Installation And User Manual Download Page 3](http://html1.mh-extra.com/html/dimplex/il095/il095_installation-and-user-manual_2505456003.webp)
3
WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY
QUALIFIED PERSON.
WARNING: DO NOT INSTALL THIS UNIT WHERE IT MAY BE SUBJECTED TO FREEZING
CONDITIONS.
BEFORE YOU START
Check that the mains electric is capable of supplying the required current.
See the rating plate for current requirements.
Check the pressure of the main water supply.
To operate correctly, the unit requires the following running pressures.
Check the rating plate to see which applies:-
Dynamic Water Pressure
Basin
Shower
Model
Minimum
Maximum
Minimum
Maximum
Up to
9.5kW
10 psi (0.7 bar)
(69 kPa)
150 psi (10.3 bar)
(1035 kPa)
15 psi (1.1 bar)
(103 kPa)
150 psi (10.3 bar)
(1035 kPa)
Up to
10.8kW
15 psi (1.1 bar)
(103 kPa)
150 psi (10.3 bar)
(1035 kPa)
20 psi (1.4 bar)
(138 kPa)
150 psi (10.3 bar)
(1035 kPa)
Up to
12.0kW
20 psi (1.4 bar)
(138 kPa)
150 psi (10.3 bar)
(1035 kPa)
25 psi (1.8 bar)
(172 kPa)
150 psi (10.3 bar)
(1035 kPa)
FIXING THE UNIT TO THE WALL
Deciding the position
•
If being used in a public place, position the unit out of reach to discourage vandalism.
•
Fit the unit onto a flat piece of wall, well away from any potential splashes of water or spray.
•
Position the unit either upright or lengthways (diagram 1), whichever is most convenient for
plumbing and wiring.
Remember to keep the lengths of hot water pipe to a minimum in order to save energy.
•
If the unit is to supply a basin, you can fit it either above or below the basin.
HOW TO INSTALL YOUR
IL095