WHAT TO DO IF THINGS GO WRONG (2) 

 

PROFESSIONAL SERVICE 

 

If the previous “Self Help” checks fail to restore the performance, you should seek professional help. 

 

The person who installed the shower is probably the best one to investigate and correct it and is 

certainly the person to contact if you have had a problem in the guarantee period. 

 

The following additional checklist is provided for the benefit of the qualified service person. 

 

WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR                                           

BEFORE REMOVING THE COVER TO MAKE CHECKS 

 

Symptom 

Cause 

What to do 

Little or no water flows 

- neon light off 

The water pressure is very low 

Use a pump to boost the supply from 

a storage tank  

Cold water only 

- neon light off  

The main water is connected to 

the OUTLET of the unit 

 

The water pressure is too low 
 

 

The thermal cut-out has 
triggered 
 

 
 

 

The flow switch is not working 

Reconnect the main supply to the 

INLET (marked in blue) 

 

Use a pump to boost the supply from 
a storage tank. 

 

Reset it by opening the unit and 
pushing the button on the cut-out 
(diagram 11). Before you do this you 

must remove the cause of the 
problem 

 

Contact Dimplex 

Water too cold 
- neon light on 

The power select screw is set to 
“LO” 

 

One element is not working 
 

 
 
 
 

 

 

The Power Supply Voltage has 
dropped. 

Change the power select screw to 
"HI” (diagram 7). 

 

Switch off the electricity supply and 
check the resistance of the elements. 

You should get the following readings. 
Loading (kW)    Resistance (Ohms) 
9.5

 

                 12.0                                 

10.8                     10.6                                     

12.0                      9.6 

 

The heater should only draw the 
following currents: 
40 amps for the 9.5kW model                   

45 amps for the 10.8kW model             
50 amps for the 12.0kW model 

Water flow too low or 
temperature too high 

The service valve is fitted to the 
OUTLET 

 

There are constrictions in the 
plumbing 

Fit the service valve to the INLET of 
the unit 

 

Check the plumbing. Only use PTFE 
tape for making pipe joints 

Water goes from hot to 

cold 

The service valve is fitted to the 

OUTLET 

Fit the service valve to the INLET of 

the unit 

 
 

 
 

 

Summary of Contents for IL095

Page 1: ...th the user after installation and demonstration It should be kept in a safe place as you may need to refer to it for general instructions or future maintenance DIMPLEX IL095 INSTANT INLINE UNVENTED W...

Page 2: ...dations All wiring and installation must be supervised by a suitably qualified person THIS APPLIANCE MUST BE EARTHED The installation must be in accordance with the current edition of BS 7671 the IEE...

Page 3: ...5 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa Up to 10 8kW 15 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa 20 psi 1 4 bar 138 kPa 150 psi 10 3 bar 1035 kPa Up to 12 0kW 20 psi 1 4 bar 138 kPa 150 p...

Page 4: ...rommet from the backplate diagram 3 Feed the cable through the grommet before you fix the unit to the wall Fixing to the wall Undo the retaining nuts and take the front cover off the unit Hold the bac...

Page 5: ...les Connecting the unit to the pipes The inlet and outlet are clearly marked on the unit They each have a 15mm straight shank connections The unit comes with a service valve diagram 5 which should be...

Page 6: ...the 10 8kW unit 50 amps for the 12 0kW unit Wire the unit using 10mm cable and a suitable Fuse MCB 45 amps Fuse MCB for the 10 8kW unit 50 amps Fuse MCB for the 12 0kW unit If the unit is fitted in a...

Page 7: ...ce valve slightly If the unit is to supply a shower turn the hot water tap on the mixer unit fully on turn the service valve anti clockwise until the neon light goes out then turn it back until the ne...

Page 8: ...have finished do not switch off the power if you are going to use the unit again shortly Shower Check that the power is switched on at the mains local isolator switch Turn on the hot or flow tap FULL...

Page 9: ...ow and the thermal cut out is operating A second outlet has been turned on Increase the supply water flow Make sure that the service valve is correctly adjusted Do not use the basin whilst using the s...

Page 10: ...n supply to the INLET marked in blue Use a pump to boost the supply from a storage tank Reset it by opening the unit and pushing the button on the cut out diagram 11 Before you do this you must remove...

Page 11: ...p C 54 49 44 Winter temp C 39 34 30 This means that with the 12 0kW unit you can shower at 39 C with a flow rate of 5 litres minute in the middle of winter The unit includes a dual thermal cut out dia...

Page 12: ...LEX UK LIMITED MILLBROOK HOUSE GRANGE DRIVE HEDGE END SOUTHAMPTON SO30 2DF We offer a technical advisory service on the telephone RING 0845 6000 5111 GUARANTEE AND CONTACT DETAILS A4 Leaflet No 579 21...

Reviews: