EN-6
English
11
11 Device information
1
Type and order code
HPK 200S
2
Design
2.1
Model
Hydraulic tower with dual differential pressureless manifold
2.2
Protection type according to EN 60529
IP 20
2.3
Installation location
Indoors
3
Technical data
3.1
Heat generation
External
3.2
Heat consumer
Unmixed heating circuit with electronic circulating pump
Yes
Mixed heating circuit with electronic circulating pump
Optionally available
1
1. Optionally, the hydraulic module can be expanded by a heating circuit with three-way mixer. The components required for this setup are available as an expansion set.
Domestic hot water preparation (adjacent tank)
Optionally available
2
2. The standard equipment of the hydraulic module contains a pump adapter (inside micrometer 180 mm; 1-1/2") as well as shut-offs for the subsequent installation of a hot water
charge pump for an adjacent hot water tank.
3.3
Buffer tank
litres
210
3.4
Diaphragm expansion vessel
Volume/admission pressure
litres / bar
24 / 1,5
Connection for additional expansion vessel
1" external thread
3.5
Start-to-leak pressure safety valve
bar
2,5
3.6
max. operating overpressure
bar
2,0
3.7
max. operating temperature
°C
85
3.8
electrical pipe heater
kW
2, 4 or 6
Immersion heater
kW
up to 6 (optional)
3.9
Sound power level
dB(A)
37
3.10 Sound pressure level at a distance of 1 m
dB(A)
31
4
Dimensions, connections and weight
4.1
Device dimensions without connections
3
H x W x L mm
3. Note that additional space is required for pipe connections, operation and maintenance.
1660 x 680 x 775
4.2
Device connections to heat generator
Inch
1 1/4" external thread
4.3
Device connections to unmixed heating system
Inch
1 1/4" external thread
4.4
Device connections to mixed heating system (optional)
Inch
1 1/4" external thread
4.5
Device connections to domestic hot water
Inch
1 1/4" external thread
4.6
Weight of the transportable unit(s) incl. Packing
kg
187
5
Electrical connection
5.1
Fuse protection control voltage
230 V [AT]
10
5.2
Fuse protection load voltage (2nd heat generator 6 kW)
230 V / 400 V [A]
32 / 16
6
Complies with the European safety regulations
4
4. See CE declaration of conformity
7
Additional model features
7.1
Water in device protected against freezing
5
5. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
7.2
Regulator internal/external
Internal