5. Controller description
5.1. Control unit
The heating device is equipped with a configurable
electronic controller, consisting of a display, a red LED
and five buttons.
The control unit is located on the right side panel.
The set functions and values are shown on the display.
The LED lights up red when the heating is ON.
5.2. Button functions
MODE
Automatic mode (week program)
Manual operation ON
Manual operation OFF
ENTER
Save entry.
PROG
Week program, set clock.
+/- buttons
Used to navigate through the menu and to change the
setting values.
5.3. Commissioning
5.3.1. Setting the time and day
The time and day are set with the following steps:
Press and hold the PROG key for three seconds.
The clock symbol appears. The hours display
flashes.
Use the
+ / -
buttons to set the hours. Press the
ENTER button. The minutes display flashes.
Use the
+ / -
buttons to set the minutes. Press the
ENTER button. The day flashes.
Use the
+ / -
buttons to set the day. Press the
ENTER button. The CLOCK symbol disappears.
Setting is complete.
5.4. Operation
5.4.1. Selecting the
operating mode
Pressing the MODE key switches the operating mode
between MANUAL ON, MANUAL OFF and AUTO.
MANUAL ON
Manual heating operation switched on.
Display alternates between room temperature
setting and the current time.
Room temperature is set using
+/-
.
MANUAL OFF
Heating operation switched off.
The current time is displayed.
Room temperature cannot be set.
NOTE
i
In MANUAL OFF operating mode, frost protection
takes place. If the room temperature is 5° C or less,
the heating device is switched on automatically.
AUTO
Automatic mode (week program) activated.
Display alternates between room temperature
setting and the current time.
Heating operation takes place in the specified
time blocks for ON and OFF.
Room temperature is set using
+/-
.
There are no factory default time blocks. These must
be defined by the user as required.
NOTE
i
Frost protection is the factory default in the OFF time
blocks. If the room temperature is 5° C or less, the
heating device is switched on automatically.
F
COPY
BLK
OFF
ON
P
DLY
AUTO
ADVANCE
MANUAL ON
M
T
W
T
S
S
OFF
Save entry
Set program
Select operating mode
Automatic operation
Copy
Time block on
F
COPY
OFF
ON
P
AUTO
ADVANCE
MANUAL
ON
M
T
W
T
S
S
OFF
Manual operation
Setting the time
Button lock
Program no. (1 - 4)
Day
Heating operation off
Heating operation on
Advance
Time block off
Value down/up