•  Checks to the refrigeration equipment

 

 Where electrical components are being changed, they shall be fit for the purpose 

and to the correct specification. At all times the manufacturer’s maintenance and 

service guidelines shall be followed. If in doubt consult the manufacturer’s technical 

department for assistance. The following checks shall be applied to installations 

using flammable refrigerants:

 

 The charge size is in accordance with the room size within which the refrigerant 

containing parts are installed;

 

 The ventilation machinery and outlets are operating adequately and are not 

obstructed;

 

 If an indirect refrigerating circuit is being used, the secondary circuit shall be 

checked for the presence of refrigerant; Marking to the equipment continues to 

be visible and legible. Markings and signs that are illegible shall be corrected; 

Refrigeration pipe or components are installed in a position where they are 

unlikely to be exposed to any substance which may corrode refrigerant containing 

components, unless the components are constructed of materials which are 

inherently resistant to being corroded or are suitably protected against being so 

corroded.

•  Checks to electrical devices

 

 Repair and maintenance to electrical components shall include initial safety checks 

and component inspection procedures. If a fault exists that could compromise 

safety, then no electrical supply shall be connected to the circuit until it is 

satisfactorily dealt with. If the fault cannot be corrected immediately but it is 

necessary to continue operation, an adequate temporary solution shall be used. 

This shall be reported to the owner of the equipment so all parties are advised.

 

 Initial safety checks shall include:

 

 That capacitors are discharged: this shall be done in a safe manner to avoid 

possibility of sparking; That there no live electrical components and wiring are 

exposed while charging, recovering or purging the system; That there is continuity 

of earth bonding.

•  Repairs to sealed components

 

 During repairs to sealed components, all electrical supplies shall be disconnected 

from the equipment being worked upon prior to any removal of sealed covers, 

etc. If it is absolutely necessary to have an electrical supply to equipment during 

servicing, then a permanently operating form of leak detection shall be located at 

the most critical point to warn of a potentially hazardous situation.

 

 Particular attention shall be paid to the following to ensure that by working on 

electrical components, the casing is not altered in such a way that the level of 

protection is affected. This shall include damage to cables, excessive number 

of connections, terminals not made to original specification, damage to seals, 

incorrect fitting of glands, etc.  Ensure that apparatus is mounted securely. Ensure 

that seals or sealing materials have not degraded such that they no longer serve 

the purpose of preventing the ingress of flammable atmospheres. Replacement 

parts shall be in accordance with the manufacturer’s specifications.

 

 NOTE:

 The use of silicon sealant may inhibit the effectiveness of some types of leak 

detection equipment. Intrinsically safe components do not have to be isolated prior 

to working on them.

15429_Dimplex DPRC29ECO-B Manual.indd   6

15429_Dimplex DPRC29ECO-B Manual.indd   6

7/09/20   4:27 PM

7/09/20   4:27 PM

Summary of Contents for DPRC29ECO-B

Page 1: ...table Air Conditioner Model DPRC29ECO B For domestic household use only INSTRUCTION MANUAL 15429_Dimplex DPRC29ECO B Manual indd 1 15429_Dimplex DPRC29ECO B Manual indd 1 7 09 20 4 27 PM 7 09 20 4 27...

Page 2: ...t place on soft unstable or non horizontal angled surfaces Never operate the appliance if a cable or connector has been damaged after appliance malfunction or if the appliance was dropped or is otherw...

Page 3: ...witch off the unit and take the plug out of the socket If you are not using the unit Before you clean or carry out maintenance on the unit If a fault occurs In the event of an electrical storm Avoid e...

Page 4: ...ption the description on label shall prevail Compliance with national gas regulations shall be observed Keep ventilation openings clear of obstruction The appliance shall be stored so as to prevent me...

Page 5: ...e checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used i...

Page 6: ...uate temporary solution shall be used This shall be reported to the owner of the equipment so all parties are advised Initial safety checks shall include That capacitors are discharged this shall be d...

Page 7: ...able for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspecte...

Page 8: ...em electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is available a...

Page 9: ...hall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working...

Page 10: ...igh Capacity in a compact size with cooling heating dehumidifying and ventilating function Temperature setting and display LED Digital display Electronic control with built in timer sleep mode Self ev...

Page 11: ...pening with sealing plug 1 2 3 4 5 6 7 Note The appearance is only for reference Please see the real product for detailed information Accessories 1 Exhaust hose 2 Hose connector 3 Window kit adapter 4...

Page 12: ...ves or other products that products that produce heat Direct sunlight Mechanical vibration or shock Excessive dust Lack of ventilation such as cabinet or bookcase Uneven surface WARNING Install the un...

Page 13: ...duct tape if required It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency Step 5 Attach the hose connector to the exhaust air ou...

Page 14: ...setting 5 Indicators LED for fan speed High Low 6 TIMER Press to set a time for the unit to automatically start or stop 7 Speed Press to switch the fan speed between HIGH and LOW 8 Digital Display Di...

Page 15: ...ture 2 Heating your room Optional for Heating Function Unit only Press MODE button repeatedly until the LED of HEAT operation lights up Press UP DOWN button to set the temperature higher than the room...

Page 16: ...es in the cooling operation or drying operation and the ambient temperature sensor senses the evaporator coil temperature is below 1 C then the compressor will stop operating for 10 minutes or until t...

Page 17: ...nit before operating Remove the plug of the water outlet opening and keep it in safe area Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction Place the...

Page 18: ...unit and unplug the power cord 2 Remove the filter mesh from the unit 3 Use a vacuum cleaner to suck dust from the filter 4 Turn the filter over and rinse the air filter under running water Let the wa...

Page 19: ...olate and ventilate area 5 Do not get in eyes on skin or on clothing Do not breathe vapors or gas 6 Prevent entry to sewers and public waters 7 Stop the source of the release if safe to do so Consider...

Page 20: ...s securely attached Water Leakage Overflow while moving the unit Empty the water tank before transport Check if the drain hose is kinked or bends Straighten the hose to avoid a trap existing Excessive...

Page 21: ...rving the machine in ventilating dry non corrosive gas and safe place indoor ATTENTION The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and mol...

Page 22: ...22 15429_Dimplex DPRC29ECO B Manual indd 22 15429_Dimplex DPRC29ECO B Manual indd 22 7 09 20 4 27 PM 7 09 20 4 27 PM...

Page 23: ...3179 Victoria Australia Ph 1300 556 816 Glen Dimplex New Zealand Ltd 38 Harris Road East Tamaki Auckland 2013 New Zealand Ph 0800 666 2824 Maintenance Warranty Recycling Do not dispose of electrical...

Page 24: ...co nz www dimplex co nz Glen Dimplex New Zealand Ltd All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Di...

Reviews: