EN-16
451905.66.06 · FD 9912
www.gdts.one
English
DHW 400+
8.2
Energy consumption during heat-up time
kWh
5.8
8.3
Power consumption during stand-by period
5
W
41
8.4
Electric energy consumption
W
EL-TC
according to EN 16147 cycle XL
kWh
7.48
8.5
COP according to EN 16147 cycle XL
3.3
8.6
Reference domestic hot water temperature
°C
55.8
8.7
Maximum usable domestic hot water quantity
litres
580
8.8
Load profile
XXL
8.9
Water heating energy efficiency
ŋ
wh
%
132
1. At temperatures below 7 °C ± 1 °C, the heating element switches on automatically and the heat pump module switches off.
2. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on outlet side).
3. Heating up of nominal volume from 10 °C to 56 °C at air intake temperature of 20 °C and humidity of 60 %
4. The information is valid for a new device with clean heat exchangers
5. At an air intake temperature of 20 °C and 60 % relative humidity.