background image

EN-2

451905.66.06 · FD 9912

www.gdts.one

English

DHW 400+

1

Please read immediately

1.1 Important notes

ATTENTION!

!!

Read these installation and operating instructions before
commissioning!

ATTENTION!

!!

Work on the domestic hot water heat pump is to be performed
by qualified personnel only! Observe accident prevention
regulations!

ATTENTION!

!!

The device cover cannot be used for carrying (the cover
cannot withstand significant forces).

ATTENTION!

!!

Once the heat pump has been set up, the guard plate must be
removed!

ATTENTION!

!!

The heat pump must not be transported overhead.

ATTENTION!

!!

When installing the on-site pipework, ensure that the pipes
are not contaminated (flush pipes before connecting the
domestic hot water heat pump if necessary).

ATTENTION!

!!

The domestic hot water heat pump must only be operated
when filled with water.

ATTENTION!

!!

The collector sensor must be a temperature sensor with the
resistance characteristic curve of a PT1000 (see Cap. 2.4.2 on
pag. 4).

ATTENTION!

!!

Disconnect the power supply before opening the domestic
hot water heat pump; possible fan coasting must be
considered.

ATTENTION!

!!

Risk of injury caused by sharp-edged fins. Fins must not be
deformed or damaged!

ATTENTION!

!!

The device must be de-energised before it can be opened.

ATTENTION!

!!

The terminal X8 can also be energized when the heat pump is
in switched-off state

ATTENTION!

!!

For settings for using photovoltaic energy. a solar thermal
system or an external boiler, domestic hot water temperatures
of >60 °C are possible and an external scald protection must
therefore be in place.

1.2 Intended use

This device is only intended for use as specified by the manu-
facturer. Any other use beyond that intended by the manufac-
turer is prohibited. This requires the user to abide by the rele-
vant project planning documents. Please refrain from
tampering with or altering the device.

1.3 Regulations / safety 

information

ATTENTION!

!!

Read these installation and operating instructions before
commissioning!

The domestic hot water heat pump is used exclusively to
heat water for domestic use and drinking water within the
specified operating temperature limits. The heating of flu-
ids other than domestic water is not permitted. Technical
regulations for domestic water installation are to be ob-
served. The nominal pipe widths for the on-site sanitary in-
stallation must be determined taking into account the
building-specific requirements and the valid directives and
regulations. Any necessary safety devices, such as pres-
sure reducing valves, must be installed according to the
specific requirements.

The following are not permitted:

It is not permissible to install the device:

It is not permissible to operate the device:

The construction and design of the domestic hot water
heat pump complies with the relevant EU directives. (See
also CE declaration of conformity).

The technician must ensure that the refrigerant is flushed
adequately to allow maintenance and repair work to be car-
ried out on refrigerant circuit components without risk. Re-
frigerant must be properly handled and disposed of; it
must not be released into the environment! 
The refrigeration circuit is "hermetically sealed" and con-
tains the fluorinated refrigerant R134a included in the
Kyoto protocol. Information on the GWP value and CO

2

equivalent of the refrigerant can be found in the chapter
Device information. The refrigerant is CFC-free, non-ozone
depleting and non-combustible.

-

Operating the pump with solvent-based or explosive ex-
haust air

-

The use of exhaust air containing grease, dust or aero-
sols 
containing adhesive substances

- The connection of extractor hoods to the 

ventilation system

- Outdoors
- In rooms which are exposed to frost
- In rooms subject to high humidity (e.g. bathrooms)
- In rooms with air which is potentially explosive

due to gases, vapours or dust

- With an empty cylinder
- During the construction phase of the building

Summary of Contents for DHW 400+

Page 1: ...tage und Gebrauchsanweisung Warmwasser W rmepumpe f r Innenaufstellung Installation and Operating Instruction Hot Water Heat Pump for Indoor Installation Instuctionsd installation et d utilisation Cha...

Page 2: ......

Page 3: ...chluss der Wasserleitungen DE 7 5 2 Anschluss der Kondensatleitung DE 7 5 3 Elektrischer Anschluss DE 7 5 4 Anschluss Luftkanal optional DE 7 6 Inbetriebnahme DE 8 6 1 Warmwasserkreislauf DE 8 7 Bedie...

Page 4: ...er hinaus gehender Gebrauch gilt als nicht bestimmungsgem Dazu z hlt auch die Beachtung der zugeh rigen Projektierungsunter lagen nderungen oder Umbauten am Ger t sind zu unterlas sen 1 3 Vorschriften...

Page 5: ...n Stutzen der Warmwasser W rmepumpe ein Luftkanalsystem DN 160 max L nge 10 m angeschlossen werden Grunds tzlich muss f r einen effektiven W rmepum penbetrieb ein Luftkurzschluss zwischen angesaugter...

Page 6: ...gelung f r den Verdichterbetrieb bernimmt die Steuerelektro nik Elektronische F hler erfassen die Wassertemperatur diese wird in Abh ngigkeit vom eingestellten Sollwert geregelt Die Einstellung des g...

Page 7: ...m den Speichermantel gelegt und an den Wasserrohrnippeln fixiert werden kann eine zweite oder dritte Trageposition bestimmt werden Bei diesem Trans portvorgang auch bei Transport mit Sackkarre ist dar...

Page 8: ...enzenden Wohnr umen empfehlenswert Ein Wasserablauf mit Siphon f r das anfallende Konden sat muss vorhanden sein Die angesaugte Luft darf nicht berm ig verunreinigt bzw stark staubbelastet sein Der Un...

Page 9: ...tstoffeins tze verbleiben nach der Montage der Wasserleitungen in ihrer Position ACHTUNG Bei Erstellung der bauseitigen Verrohrung sind Verschmutzungen im Leitungssystem zu vermeiden evtl vor Anschlus...

Page 10: ...ellen ffnen bis keine Luft mehr fest zustellen ist Gesamten Warmwasserkreislauf auf Dichtheit pr fen Spannungsversorgung herstellen W rmepumpe einschalten Die gew nschte Warmwassertemperatur z B 45 C...

Page 11: ...ur die auch w h rend einer programmierten Absenkung nicht unterschritten werden soll Hysterese 2 K 3 K 10 K Einstellung der Schalt Hysterese Elektroheizung Modus Verz gerung Boost Dauer Boost Solltemp...

Page 12: ...altung des Pho tovoltaikeingangs aktiv ist Der erh hte Sollwert ist auch aktiv wenn die Luftansaugtemperatur den Betrieb der W rmepumpe nicht erlaubt Die Anforderung wird in dem Fall mit dem elektrisc...

Page 13: ...deinstellungen Sprache Einstellung der Sprache Datum Einstellung des aktuellen Datums Uhrzeit Einstellung der aktuellen Uhrzeit Solltemperatur Einstellung der gew nschten Warmwassertemperatur Absenkun...

Page 14: ...lheizen kann sie auch oberhalb der 7 C Grenze manuell eingeschaltet werden 7 3 3 Zweiter W rmeerzeuger Mit Hilfe des integrierten Rohrw rmetauschers 1 35 m kann ein vorhandener W rmeerzeuger zur Aufhe...

Page 15: ...vol taikfunktion Der Betrieb der W rmepumpe mit Strom aus der Photovoltaikanlage wird im Display angezeigt HINWEIS Die Warmwassersolltemperatur im Photovoltaikbetrieb sollte auf max 55 C eingestellt w...

Page 16: ...ausgef hrt werden Unfallverh tungsvorschriften sind zu beachten Die W rmepumpe l uft nicht Bitte berpr fen Sie ob der Stecker eingesteckt ist an der Tastatur der Stand By Modus gew hlt wurde an der St...

Page 17: ...d F llmengen 5 1 Abmessungen H he min x Breite x Tiefe mm 2043 x 740 x 776 5 2 Luftkanalanschluss Durchmesser Nennweite mit EPP L ftungsrohr mm 190 DN 160 5 3 Gewicht unbef llt kg 132 5 4 K ltemittel...

Page 18: ...armwassermenge 4 5 Liter 580 8 8 Lastprofil 4 5 XXL 8 9 Warmwasserbereitungs Energieeffizienz wh 4 5 132 1 Bei Temperaturen unter 7 C 1 C schaltet sich automatisch der Heizstab ein und das W rmepumpen...

Page 19: ...lt wenn vom Kunden oder einem Drit ten die entsprechenden VDE Vorschriften die Bestimmungen der rtlichen Versorgungsunternehmen oder unsere Montage und Ge brauchsanweisung sowie die in den Projektieru...

Page 20: ...DE 18 451905 66 06 FD 9912 www gdts one Deutsch DHW 400...

Page 21: ...the water pipes EN 7 5 2 Connecting the condensate pipe EN 7 5 3 Electrical connection EN 7 5 4 Air duct connection optional EN 7 6 Commissioning EN 8 6 1 Domestic hot water system EN 8 7 Operation a...

Page 22: ...device 1 3 Regulations safety information ATTENTION Read these installation and operating instructions before commissioning The domestic hot water heat pump is used exclusively to heat water for dome...

Page 23: ...fectively air short circuits between the drawn in air and the blown out air must always be avoided This can for example be achieved through the use of a bend on the intake and outlet side Falling outl...

Page 24: ...lation for compressor operation is carried out by the con trol electronics Electronic sensors measure the water tempera ture which is regulated based on the setpoint The desired tem perature level set...

Page 25: ...created with the help of ropes or carrying slings these may be wrapped around the cylinder casing and at tached to the water pipe nipples When transporting the heat pump in this manner or with a hand...

Page 26: ...d Condensate drainage with a siphon must be provided The air taken in may not be excessively contaminated or contain large amounts of dust The load bearing capacity of the foundation must be suffi cie...

Page 27: ...in in their positions after installation ATTENTION When installing the on site pipework ensure that the pipes are not contaminated flush pipes before connecting the domestic hot water heat pump if nec...

Page 28: ...urge the domestic hot water circuit open domestic hot water taps at the highest extraction points until there are no more traces of air Check the entire domestic hot water system for leaks Establish t...

Page 29: ...cess Hysteresis 2 K 3 K 10 K Sets the switching hysteresis Electric heater Mode Delay Boost period Boost set temp ECO AUTO 2 h 8 h 16 h 1 h 4 h 8 h 25 C 60 C 85 C ECO Only switches in the event of an...

Page 30: ...if the air intake temperature does not allow the heat pump to operate In this case the request is processed with the electric heating ele ment or where present the 2nd heat generator Information Oper...

Page 31: ...st commissioning Basic settings Language Sets the language Date Sets the current date Time Sets the current time Set temperature Sets the desired domestic hot water temperature Lower Sets the reduced...

Page 32: ...function 7 3 3 Second heat generator An existing heat generator can be used to heat the cylinder using the integrated tube heat exchanger 1 m The use of a 2nd heat generator must be activated in the...

Page 33: ...us base load of the building The solar thermal func tion has priority over the photovoltaic function The display shows that the heat pump is being operated using electricity from the photovoltaic inst...

Page 34: ...s to be performed by qualified personnel only Observe accident prevention regulations Check the following the plug is plugged in stand by mode has been selected on the keyboard the socket is supplied...

Page 35: ...ensions height min x width x depth mm 2043 x 740 x 776 5 2 Air duct connection diameter normial width with EPP ventilating pipe mm 190 DN160 5 3 Weight empty kg 132 5 4 Refrigerant R 134a total fillin...

Page 36: ...ot water quantity 4 5 litres 580 8 8 Load profile 4 5 XXL 8 9 Water heating energy efficiency wh 4 5 132 1 At temperatures below 7 C 1 C the heating element switches on automatically and the heat pump...

Page 37: ...s conduites d eau FR 7 5 2 Raccordement de la conduite d coulement des condensats FR 7 5 3 Branchements lectriques FR 7 5 4 Raccordement de la gaine d air en option FR 7 6 Mise en service FR 8 6 1 Cir...

Page 38: ...es projets doit galement tre prise en compte Toute modification ou transformation sur l appareil est proscrire 1 3 Prescriptions consignes de s curit ATTENTION Avant la mise en service lire ces instru...

Page 39: ...ffe eau thermodynamique Pour assurer un fonc tionnement efficace de la pompe chaleur il convient d une mani re g n rale d viter un court circuit d air entre aspiration et chappement de l air On peut e...

Page 40: ...et r gule le fonctionnement du compresseur Les sondes lectroniques mesurent la temp ra ture de l eau laquelle est r gl e en fonction de la valeur de consigne d finie Le niveau de temp rature souhait v...

Page 41: ...ou de sangles ces derni res peuvent tre mises autour de l enveloppe du ballon et fix es aux embouts des tuyaux Dans ce type de transport y compris par diable veiller ne pas d passer l inclinaison max...

Page 42: ...es d habitation avoisinantes Pr voir un coulement des condensats avec siphon L air aspir ne doit pas contenir trop d impuret s et ne doit pas tre fortement charg en poussi res Le sol doit pr senter un...

Page 43: ...TION Lors du raccordement aux tuyauteries du client viter la p n tration d impuret s dans le circuit rincer ventuellement les conduites avant de raccorder le chauffe eau thermodynamique 5 2 Raccordeme...

Page 44: ...nets d eau chaude aux points de prise sup rieurs jusqu purge com pl te de l air V rifier l tanch it du circuit d eau chaude dans son en semble tablir l alimentation lectrique Mettre en marche la pompe...

Page 45: ...ne doit pas descendre y compris pendant une dur e d abaissement programm e Hyst r sis 2 K 3 K 10 K R glage de l hyst r sis de commutation Chauffage lectrique Mode Temporisation Dur e boost Temp consi...

Page 46: ...cas de commutation de l entr e photovolta que La valeur de consigne major e est galement active si la temp rature de l air aspir n autorise pas le fonctionnement de la pompe chaleur Dans ce cas la dem...

Page 47: ...eurs fr quences cran d accueil lors de la mise en service initiale R glages de base Langue R glage de la langue Date R glage de la date actuelle Heure R glage de l heure actuelle Temp rature de consi...

Page 48: ...ateur de chaleur L changeur thermique tubes int gr 1 m permet d utiliser un g n rateur de chaleur d j install pour le chauffage du bal lon Il convient d activer l utilisation d un deuxi me g n rateur...

Page 49: ...la charge de base du foyer La fonction solaire thermique est prioritaire sur la fonction photovolta que Le fonctionnement de la pompe chaleur avec du courant pro venant de l installation photovolta q...

Page 50: ...on des accidents La pompe chaleur ne fonctionne pas Veuillez v rifier que le connecteur est bien dans la prise le mode Veille n a pas t s lectionn au clavier la prise de courant est aliment e la temp...

Page 51: ...Dimensions hauteur min x largeur x profondeur mm 2043 x 740 x 776 5 2 Diam tre de raccordement la gaine d air diam tre norminal avec EPP tuyau d a ration mm 190 DN 160 5 3 Poids vide kg 132 5 4 Fluide...

Page 52: ...es 580 8 8 Profil de soutirage 4 5 XXL 8 9 Efficacit nerg tique pour le chauffage de l eau wh 4 5 132 1 une temp rature inf rieure 7 C 1 C la r sistance lectrique se met automatiquement en marche et l...

Page 53: ...d int gration hydrauliqueA IV 2 2 Legende Legend L gende A IV 2 3 Einbindungsschema W rmetauscher an thermische Solaranlage Heat Exchanger Integration Diagram for Thermal Solar Installation Sch ma d i...

Page 54: ...ww gdts one Anhang Appendix Annexes DHW 400 1 Ma bild Dimension drawing Sch ma cot 1 1 Ma bild Dimension drawing Sch ma cot 1803 2053 1553 970 770 760 687 55 90 11 1 2 3 4 5 6 7 8 9 10 700 90 30 740 1...

Page 55: ...e Anode anticorrosion 5 Zirkulationsleitung Circulation pipe Conduite de circulation 6 Elektrischer Heizstab Electric heationg element Cartouche lectrique chauffante 7 W rmetauscher Eingang Rp1 Heat e...

Page 56: ...lapet anti reflux 5 Manometeranschlussstutzen Pressure gauge connecting stubs Tubulures de raccordement manom tre 6 Entleerungsventil Drain valve Vanne de vidange 7 Membran Sicherheitsventil Diaphragm...

Page 57: ...agklappe Check valve Clapet anti retour Hahn Tap Robinet Thermometer Thermometer Thermom tre vom Kollektor From the collector en provenance du collecteur Sicherheitsventil Safety valve Soupape de s cu...

Page 58: ...external components Branchement de la composants externe 3 2 Legende Legend L gende Klemme Terminal Borne Externe Komponente External component Composant externe X4 M16 Umw lzpumpe 2 WE Circulating pu...

Page 59: ...kl rung Declaration of Conformity D claration de conformit Die aktuelle CE Konformit tserkl rung finden sie als Download unter You can find and download the current CE conformity declaration at Vous p...

Page 60: ...tschland GmbH Gesch ftsbereich GDTS Am Goldenen Feld 18 D 95326 Kulmbach Irrt mer und nderungen vorbehalten Subject to alterations and errors Sous r serve d erreurs et modifications 49 0 9221 709 9245...

Reviews: