www.gdts.one
451905.66.06 · FD 9912
EN-9
DHW 400+
English
7.2 Menu structure
Parameter change: The menu is accessed using the
"Menu"
key. In this menu, changes can be made to parameters. The de-
sired menu item is selected with the arrow keys
"UP" "DOWN"
.
The submenu is accessed using the
"OK"
key.
In this submenu, the parameter that is to be changed can be se-
lected (also using the arrow keys). The
"OK"
key is used to se-
lect the marked value, which can then be changed via the arrow
keys. The entry is completed by pressing the
"OK
" key again.
w
Menu block
Menu item
Parameter
Value
Description
Settings
Time
00:00
Time setting (24 hour time display)
Date
DD:MM:YYYY
Date setting (Day:Month:Year)
Language
DEUTSCH
ENGLISH
FRANCAIS
ITALIANO
POLSKI
Language selection
Signal tone
On
Off
Setting key tone on / off
Backlight
0 % ...
50 %
...100 %
Setting display backlight
Factory setting
Factory setting reset
Type
DHW 400+
Domestic water heat pump DHW 400+
with additional heat exchanger
Domestic hot
water
Set temperature
25 °C ...
45 °C
... 85 °C
Sets the desired domestic hot water set temperature
Lower
15 °C ...
25 °C
... 40 °C
Sets the minimum hot water temperature, which should also not be
undershot for the duration of a programmed lower process.
Hysteresis
2 K ...
3 K
... 10 K
Sets the switching hysteresis
Electric heater
Mode
Delay
Boost period
Boost set temp.
ECO
AUTO
2 h ...
8 h
...16 h
1 h ...
4 h
... 8 h
25 °C ...
60 °C
... 85 °C
ECO: Only switches in the event of an error and with PV b./t., ther-
mal disinfection on
Boost: adjustable time (once, regardless of the Auto/Eco setting)
Boost: adjustable set temperature
Time programs
Therm. disinfection
Thermal disinfection
Start
00:00
... 23:59
Sets the start time for thermal disinfection (24 hour time display)
Days
Mo ...
Su
Sets the day on which thermal disinfection should be activated
Set value
60 °C ...
65 °C
... 85 °C
Sets the set temperature for thermal disinfection.
1st lower
Start
00:00
... 23:59
Sets the start time for lowering the domestic hot water set temper-
ature
End
00:00
... 23:59
Sets the end time for lowering the domestic hot water set tempera-
ture
Days
Su
... Mo
Mo - Fr
Sa - Su
Mo - Su
Sets the weekday / block of days on which the lower should be acti-
vated
2nd lower
Start
00:00
... 23:59
Sets the start time for lowering the domestic hot water set temper-
ature
End
00:00
... 23:59
Sets the end time for lowering the domestic hot water set tempera-
ture
Days
Su
... Mo
Mo - Fr
Sa - Su
Mo - Su
Sets the weekday / block of days on which the lower should be acti-
vated
Solar
Selection
Off
Bivalent
Sol
Choice of additional heat source
Off: (no add. heat source)
Bivalent: 2nd heat generator, e.g. oil, gas or wood boiler
Sol: Thermal solar energy system
Summary of Contents for DHW 400+
Page 2: ......
Page 20: ...DE 18 451905 66 06 FD 9912 www gdts one Deutsch DHW 400...