 Operation and 

 

maintenance

2

  

WARNINg: 

Before undertaking cleaning or 

maintenance work on the appliance, disconnect the 

electricty supply.

Since the appliance contains no moving parts little 

maintenance is required beyond cleaning and element 

replacement.  It is however essential that the heater is 

not operated with an accumulation of dust or dirt on the 

element, as this can cause a build up of heat and eventual 

damage.  For this reason the heater must be inspected 

regularly, depending upon conditions and at least at yearly 

intervals.  Allow adequate time for element and body 

casing to cool before attempting to work on the heater - a 

minimum of 30 minutes is recommended.

element Replacement

 

(Figure 4)

  

WARNINg: 

Before undertaking this task ensure the 

heater is disconnected from the elecetirity supply and 

left to cool for a minimum of 30 minutes.

The heater should be taken off the wall.

1. 

Remove 3 screws to remove the rain shield (Figure 

2. 

4-A) to gain access to the control box on the back of 

the heater.

Remove 4 screws to remove the terminal block plate 

3. 

(Figure 4-B) and disconnect the terminal block.
Remove 8 screws to remove the control box (Figure 

4. 

4-C).
This will allow access to the elements.  Remove 

5. 

the retaining clips and spring clips (F) to loosen the 

elements.

Disconnect the elements from their terminal blocks.

6. 

even and interrupted distribution of radiation to the area(s) 

to be heated.
When deciding upon the best location, condisteration must 

be given to the following requirements:

Avoid structures which might vibrate, e.g. crane 

1. 

gantries. These could adversly affect element life.
Comfort and safety could be compromised unless the 

2. 

heater is mounted at or above 72” (1.8m) from ground 

level.
Allow a minimum of 19 3/4” (500mm) minimum 

3. 

clearance between the top or side of the heater and 

any horizontal surface.

  

WARNINg:

 Please ensure all packaging is removed 

from the appliance before switching on.  Remove the 

guard as shown in Figure 3, remove element packaging 

and replace guard.

Wiring

  

WARNINg:

: Wiring procedures and connections should 

be in accordance with the National Electric code (NEC) 

and local codes.

Remove 3 screws to remove the rain shield (Figure 

1. 

4-A) to gain access to the control box on the back of 

the heater.

Remove 4 screws to remove the terminal block plate 

2. 

(Figure 4-B).
Run wiring through hole in cover and connect to 

3. 

appropriate terminal on terminal block, and the ground 

wire to screw on back of cover.

Reassemble unit.

4. 